1.
Ophthalmic Physiol Opt ; 44(2): 301-310, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37984831

RESUMEN

PURPOSE: Limitations of existing diffractive multifocal designs for presbyopia correction include discrete foci and photic phenomena such as halos and glare. This study aimed to explore a methodology for developing refractive extended depth-of-focus (EDoF) lenses based on a periodic power profile. METHODS: The proposed design technique employed an optical power profile that periodically alternated between far, intermediate and near distances across the pupil radius. To evaluate the lens designs, optical bench testing was conducted. The impact on visual performance was assessed using a spatial light modulator-based adaptive optics vision simulator in human subjects. Additionally, the effects of pupil size change and lens decentration on retinal image quality were examined. A comparative performance analysis was carried out against a typical diffractive trifocal design and a monofocal lens. RESULTS: The proposed design method was found to be effective in uniformly distributing light energy across all object distances within the desired depth of focus (DoF). While trade-offs between overall image quality and DoF still exist, the EDoF lens design, when tested in human subjects, provided a continuous DoF spanning over 2.25 D. The results also revealed that the EDoF design had a slightly higher dependence on changes in pupil size and lens decentration than the diffractive trifocal design. CONCLUSION: The proposed design method showed significant potential as an approach for developing refractive EDoF ophthalmic lenses. These lenses offer a continuous DoF but are slightly more susceptible to variations in pupil size and decentration compared with the diffractive trifocal design.


Asunto(s)
Lentes Intraoculares , Presbiopía , Humanos , Agudeza Visual , Refracción Ocular , Visión Ocular , Diseño de Prótesis
2.
Proc Natl Acad Sci U S A ; 118(23)2021 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-34074775

RESUMEN

Stereovision is the ability to perceive fine depth variations from small differences in the two eyes' images. Using adaptive optics, we show that even minute optical aberrations that are not clinically correctable, and go unnoticed in everyday vision, can affect stereo acuity. Hence, the human binocular system is capable of using fine details that are not experienced in everyday vision. Interestingly, stereo acuity varied considerably across individuals even when they were provided identical perfect optics. We also found that individuals' stereo acuity is better when viewing with their habitual optics rather than someone else's (better) optics. Together, these findings suggest that the visual system compensates for habitual optical aberrations through neural adaptation and thereby optimizes stereovision uniquely for each individual. Thus, stereovision is limited by small optical aberrations and by neural adaptation to one's own optics.


Asunto(s)
Adaptación Fisiológica , Visión Binocular/fisiología , Agudeza Visual/fisiología , Adulto , Femenino , Humanos , Masculino , Óptica y Fotónica
3.
Ophthalmology ; 130(7): 726-734, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37061911

RESUMEN

PURPOSE: To develop a questionnaire with standardized questions and images about visual symptoms and satisfaction administered before and after cataract surgery with monofocal and various (premium) intraocular lenses (IOLs). DESIGN: A prospective, observational study of cataract surgery patients completing a self-administered questionnaire preoperatively and postoperatively at 4 to 6 months. PARTICIPANTS: Five hundred fifty-four patients with plans to undergo implantation of the same IOL in both eyes on separate occasions in 20 ophthalmology practices. METHODS: An 86-item questionnaire with standardized images assessed the following 14 symptoms: glare, blurry vision, starbursts, hazy vision, snowballs, halos, floaters, double images, rings and spider webs, light flashes with eyes closed, distortion, light flashes with eyes open, shimmering images, and dark crescent-shaped shadows. MAIN OUTCOME MEASURES: Symptom severity and level of symptom bother, satisfaction with vision, quality of vision, and ability to see without corrective lenses or eyeglasses. RESULTS: Except for dark crescent-shaped shadows, the report of visual symptoms significantly decreased postoperatively. Best uncorrected binocular visual acuity improved from 0.47 (20/59 Snellen visual acuity values) ± 0.35 logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.12 (20/26 Snellen visual acuity values) ± 0.12 logMAR postoperatively. Patients' ratings of intermediate vision as good to excellent improved significantly from 12% preoperatively to 71% postoperatively, and patients' ratings of distance vision improved from 8% preoperatively to 85% postoperatively. After surgery, 84% reported that they were somewhat, very, or completely satisfied with their vision. Most patients (88%) reported that they could see pretty well, very well, or perfectly well without corrective lenses after surgery. CONCLUSIONS: The Assessment of IntraOcular Lens Implant Symptoms questionnaire can be used across a wide variety of IOLs to evaluate visual symptoms and satisfaction with a growing segment of the market, premium IOLs, that target intermediate and near vision, in addition to distance vision. Compared to patients receiving monofocal IOLs, patients receiving premium IOLs appear to be more challenging to satisfy because of their requirements for distance, intermediate, and near vision, and their desire to be free of eyeglasses postoperatively. This instrument provides a structured, uniform tool for regulators, researchers, and ophthalmologists in everyday practice to gain insights into patients' experiences. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Asunto(s)
Opacificación Capsular , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares/métodos , Estudios Prospectivos , Satisfacción del Paciente , Diseño de Prótesis , Trastornos de la Visión
4.
Annu Rev Biomed Eng ; 23: 277-306, 2021 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-33848431

RESUMEN

As the human eye ages, the crystalline lens stiffens (presbyopia) and opacifies (cataract), requiring its replacement with an artificial lens [intraocular lens (IOL)]. Cataract surgery is the most frequently performed surgical procedure in the world. The increase in IOL designs has not been paralleled in practice by a sophistication in IOL selection methods, which rely on limited anatomical measurements of the eye and the surgeon's interpretation of the patient's needs and expectations. We propose that the future of IOL selection will be guided by 3D quantitative imaging of the crystalline lens to map lens opacities, anticipate IOL position, and develop fully customized eye models for ray-tracing-based IOL selection. Conversely, visual simulators (in which IOL designs are programmed in active elements) allow patients to experience prospective vision before surgery and to make more informed decisions about which IOL to choose. Quantitative imaging and optical and visual simulations of postsurgery outcomes will allow optimal treatments to be selected for a patient undergoing modern cataract surgery.


Asunto(s)
Catarata , Cristalino , Oftalmología , Humanos , Implantación de Lentes Intraoculares , Estudios Prospectivos
5.
J Vis ; 21(8): 21, 2021 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-34415998

RESUMEN

Vergence and accommodation can be mismatched under virtual reality viewing conditions, and this mismatch has been thought to be one of the main causes of visual discomfort. The goal of this study was to investigate how optical conditions of the eyes affect accommodative responses to different convergence. Specifically, we hypothesized that extending the depth of focus (DoF) could weaken the control of the screen on accommodation, so that accommodation could be induced by convergence. To test this hypothesis, we extended the DoF using Zernike spherical aberrations (fourth and sixth orders) induced by a binocular adaptive optics (AO) vision simulator. Nine normal subjects between the ages of 21 and 34 (26 ± 5) years were recruited. Three optical conditions were generated: AO condition (aberration-free), monovision condition, and extended depth of focus (EDoF) condition. Binocular accommodative responses, along with binocular visual acuity and stereoacuity, were measured under all three optical conditions with varied binocular vergence levels. At 3 diopters of binocular convergence, the EDoF condition was the most efficient in inducing excessive accommodative response compared with the monovision condition and the AO condition. Visual acuity was impaired with EDoF as compared with the other two conditions. The average stereoscopic thresholds (at 0 vergence) under the EDoF condition were degraded compared with the AO condition but were superior to those of the monovision condition. Therefore, despite some compromise to visual performance, extending the DoF could allow for a more natural vergence-accommodation relationship, providing the potential for alleviating the vergence-accommodation conflict and associated visual fatigue symptoms in virtual reality.


Asunto(s)
Acomodación Ocular , Convergencia Ocular , Adulto , Humanos , Visión Binocular , Visión Monocular , Agudeza Visual , Adulto Joven
6.
Ophthalmic Physiol Opt ; 38(3): 326-336, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29691930

RESUMEN

PURPOSE: To characterise the impact of monofocal soft contact lens (SCL) and bifocal SCLs on refractive error, depth of focus (DoF) and orientation of blur in the peripheral visual field. METHODS: Monofocal and two bifocal SCLs, Acuvue Bifocal (AVB, Johnson & Johnson) and Misight Dual Focus (DF, CooperVision) with +2.0 D add power were modelled using a ray tracing program (ZEMAX) based on their power maps. These SCLs were placed onto the anterior corneal surface of the simulated Atchison myopic eye model to correct for -3.0 D spherical refractive error at the fovea. To quantify through-focus retinal image quality, defocus from -3.5 D to 1.5 D in 0.5 D steps was induced at each horizontal eccentricity from 0 to 40° in 10° steps. Wavefront aberrations were computed for each visual eccentricity and defocus. The retinal images were simulated using a custom software program developed in Matlab (The MathWorks) by convolving the point spread function calculated from the aberration with a reference image. The convolved images were spatially filtered to match the spatial resolution limit of each peripheral eccentricity. Retinal image quality was then quantified by the 2-D cross-correlation between the filtered convolved retinal images and the reference image. Peripheral defocus, DoF and orientation of blur were also estimated. RESULTS: In comparison with the monofocal SCL, the bifocal SCLs degraded retinal image quality while DoF was increased at fovea. From 10 to 20°, a relatively small amount of myopic shift (less than 0.3 D) was induced by bifocal SCLs compared with monofocal. DoF was also increased with bifocal SCLs at peripheral vision of 10 and 20°. The trend of myopic shift became less consistent at larger eccentricity, where at 30° DF showed a 0.75 D myopic shift while AVB showed a 0.2 D hyperopic shift and both AVB and DF exhibited large relative hyperopic defocus at 40°. The anisotropy in orientation of blur was found to increase and change its direction through focus beyond central vision. This trend was found to be less dominant with bifocal SCLs compared to monofocal SCL. CONCLUSIONS: Bifocal SCLs have a relatively small impact on myopic shift in peripheral refractive error while DoF is increased significantly. We hypothetically suggest that a mechanism underlying myopia control with these bifocal or multifocal contact lenses is an increase in DoF and a decrease in anisotropy of peripheral optical blur.


Asunto(s)
Lentes de Contacto Hidrofílicos , Refracción Ocular/fisiología , Errores de Refracción/terapia , Campos Visuales/fisiología , Diseño de Equipo , Fóvea Central/fisiopatología , Humanos , Errores de Refracción/fisiopatología
7.
J Vis ; 16(5): 1, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26928220

RESUMEN

Optical blur in the peripheral retina is known to be highly anisotropic due to nonrotationally symmetric wavefront aberrations such as astigmatism and coma. At the neural level, the visual system exhibits anisotropies in orientation sensitivity across the visual field. In the fovea, the visual system shows higher sensitivity for cardinal over diagonal orientations, which is referred to as the oblique effect. However, in the peripheral retina, the neural visual system becomes more sensitive to radially-oriented signals, a phenomenon known as the meridional effect. Here, we examined the relative contributions of optics and neural processing to the meridional effect in 10 participants at 0°, 10°, and 20° in the temporal retina. Optical anisotropy was quantified by measuring the eye's habitual wavefront aberrations. Alternatively, neural anisotropy was evaluated by measuring contrast sensitivity (at 2 and 4 cyc/deg) while correcting the eye's aberrations with an adaptive optics vision simulator, thus bypassing any optical factors. As eccentricity increased, optical and neural anisotropy increased in magnitude. The average ratio of horizontal to vertical optical MTF (at 2 and 4 cyc/deg) at 0°, 10°, and 20° was 0.96 ± 0.14, 1.41 ± 0.54 and 2.15 ± 1.38, respectively. Similarly, the average ratio of horizontal to vertical contrast sensitivity with full optical correction at 0°, 10°, and 20° was 0.99 ± 0.15, 1.28 ± 0.28 and 1.75 ± 0.80, respectively. These results indicate that the neural system's orientation sensitivity coincides with habitual blur orientation. These findings support the neural origin of the meridional effect and raise important questions regarding the role of peripheral anisotropic optical quality in developing the meridional effect and emmetropization.


Asunto(s)
Sensibilidad de Contraste/fisiología , Retina/fisiología , Campos Visuales/fisiología , Percepción Visual/fisiología , Adulto , Anisotropía , Astigmatismo , Femenino , Humanos , Masculino , Orientación , Adulto Joven
8.
Exp Eye Res ; 132: 231-9, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25633347

RESUMEN

In this study, we explore the usage of ocular surface temperature (OST) decay patterns to distinguished between dry eye patients with aqueous deficient dry eye (ADDE) and meibomian gland dysfunction (MGD). The OST profiles of 20 dry eye subjects were measured by a long-wave infrared thermal camera in a standardized environment (24 °C, and relative humidity (RH) 40%). The subjects were instructed to blink every 5 s after 20 âˆ¼ 25 min acclimation. Exponential decay curves were fit to the average temperature within a region of the central cornea. We find the MGD subjects have both a higher initial temperature (p < 0.022) and a higher asymptotic temperature (p < 0.007) than the ADDE subjects. We hypothesize the temperature difference among the subpopulations is due to tear volume and heat transfer mechanisms. To study the validity of our claim, we develop a mathematical model, referred to as the thermal impulse perturbation (TIP) model. We conclude that long-wave-infrared thermal imaging is a plausible tool in assisting with the classification of dry eye patient.


Asunto(s)
Temperatura Corporal/fisiología , Técnicas de Diagnóstico Oftalmológico , Síndromes de Ojo Seco/diagnóstico , Adulto , Anciano , Síndromes de Ojo Seco/fisiopatología , Enfermedades de los Párpados/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fotograbar/métodos
9.
J Refract Surg ; 31(5): 300-7, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25974968

RESUMEN

PURPOSE: To investigate the correlations existing between a trifocal intraocular lens (IOL) and a varifocal IOL using the "ex vivo" optical bench through-focus image quality analysis and the clinical visual performance in real patients by study of the defocus curves. METHODS: This prospective, consecutive, nonrandomized, comparative study included a total of 64 eyes of 42 patients. Three groups of eyes were differentiated according to the IOL implanted: 22 eyes implanted with the varifocal Lentis Mplus LS-313 IOL (Oculentis GmbH, Berlin, Germany); 22 eyes implanted with the trifocal FineVision IOL (Physiol, Liege, Belgium), and 20 eyes implanted with the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Visual outcomes and defocus curve were evaluated postoperatively. Optical bench through-focus performance was quantified by computing an image quality metric and the cross-correlation coefficient between an unaberrated reference image and captured retinal images from a model eye with a 3.0-mm artificial pupil. RESULTS: Statistically significant differences among defocus curves of different IOLs were detected for the levels of defocus from -4.00 to -1.00 diopters (D) (P < .01). Significant correlations were found between the optical bench image quality metric results and logMAR visual acuity scale in all groups (Lentis Mplus group: r = -0.97, P < .01; FineVision group: r = -0.82, P < .01; Acrys of group: r = -0.99, P < .01). Linear predicting models were obtained. CONCLUSIONS: Significant correlations were found between logMAR visual acuity and image quality metric for the multifocal and monofocal IOLs analyzed. This finding enables surgeons to predict visual outcomes from the optical bench analysis.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Diseño de Prótesis , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Longitud Axial del Ojo/patología , Femenino , Humanos , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Modelos Teóricos , Estudios Prospectivos
10.
J Vis ; 15(6): 17, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26024464

RESUMEN

Monovision presbyopia interventions exploit the binocular nature of the visual system by independently manipulating the optical properties of the two eyes. It is unclear, however, how individual variations in ocular dominance affect visual function in monovision corrections. Here, we examined the impact of sensory ocular dominance on visual performance in both traditional and modified monovision presbyopic corrections. We recently developed a binocular adaptive optics vision simulator to correct subjects' native aberrations and induce either modified monovision (1.5 D anisometropia, spherical aberration of +0.1 and -0.4 µm in distance and near eyes, respectively, over 4 mm pupils) or traditional monovision (1.5 D anisometropia). To quantify both the sign and the degree of ocular dominance, we utilized binocular rivalry to estimate stimulus contrast ratios that yield balanced dominance durations for the two eyes. Through-focus visual acuity and contrast sensitivity were measured under two conditions: (a) assigning dominant and nondominant eye to distance and near, respectively, and (b) vice versa. The results revealed that through-focus visual acuity was unaffected by ocular dominance. Contrast sensitivity, however, was significantly improved when the dominant eye coincided with superior optical quality. We hypothesize that a potential mechanism behind this observation is an interaction between ocular dominance and binocular contrast summation, and thus, assignment of the dominant eye to distance or near may be an important factor to optimize contrast threshold performance at different object distances in both modified and traditional monovision.


Asunto(s)
Predominio Ocular/fisiología , Presbiopía/fisiopatología , Presbiopía/terapia , Retina/fisiopatología , Visión Monocular/fisiología , Adulto , Lentes de Contacto , Sensibilidad de Contraste/fisiología , Femenino , Humanos , Masculino , Agudeza Visual/fisiología , Adulto Joven
11.
Res Sq ; 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38410431

RESUMEN

We investigated how long-term visual experience with habitual spherical aberration (SA) influences subjective depth of focus (DoF). Nine healthy cycloplegic eyes with habitual SAs of different signs and magnitudes were enrolled. An adaptive optics (AO) visual simulator was used to measure through-focus high-contrast visual acuity after correcting all monochromatic aberrations and imposing +0.5 µm and -0.5 µm SAs for a 6-mm pupil. The positive (n=6) and negative (n=3) SA groups ranged from 0.17 to 0.8 µm and from -1.2 to -0.12 µm for a 6-mm pupil, respectively. For the positive habitual SA group, the median DoF with positive AO-induced SA (2.18D) was larger than that with negative AO-induced SA (1.91D); for the negative habitual SA group, a smaller DoF was measured with positive AO-induced SA (1.81D) than that with negative AO-induced SA (2.09D). The difference in the DoF of individual participants between the induced positive and negative SA groups showed a quadratic relationship with the habitual SA. Subjective DoF tended to be larger when the induced SA in terms of the sign and magnitude was closer to the participant's habitual SA, suggesting the importance of considering the habitual SA when applying the extended DoF method using optical or surgical procedures.

12.
Biomed Opt Express ; 15(3): 1618-1629, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38495697

RESUMEN

Extended depth-of-focus (EDoF) intraocular lenses (IOLs) are typically evaluated using commercially available aberrometers. Given the intricate optical design of these IOLs, employing an appropriate wavefront reconstruction method with a sufficient sampling resolution of the aberrometer is crucial. A high-resolution Shack-Hartmann wavefront sensor was developed by magnifying the pupil aperture by a factor of five onto a lenslet array (pitch: 133 µm) and utilizing a full-frame CMOS sensor (24 by 36 mm), resulting in a 26.6 µm sampling resolution. Zonal wavefront reconstruction was used and compared with Zernike-based modal wavefront reconstruction to retain detailed local slope irregularities. Four refractive EDoF IOLs with a power of 20D were examined, and the wavefront difference between the zonal and modal methods, expressed as the root mean squared error (RMSE), remained significant for two of the IOLs up to the 16th-order Zernike spherical aberrations (SAs). Conversely, a negligibly small RMSE was observed for the other two IOLs, as long as the Zernike SAs were higher than the 6th order. The raytracing simulation results from the zonal wavefronts exhibited a stronger correlation with the results of recent optical bench studies than those from the modal wavefronts. The study suggests that certain recent refractive EDoF IOLs possess a complex optical profile that cannot be adequately characterized by limited orders of SAs.

13.
Invest Ophthalmol Vis Sci ; 65(4): 14, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38578621

RESUMEN

Purpose: This study aims to examine the short-term peripheral choroidal thickness (PChT) response to signed defocus blur, both with and without native peripheral aberrations. This examination will provide insights into the role of peripheral aberration in detecting signs of defocus. Methods: The peripheral retina (temporal 15°) of the right eye was exposed to a localized video stimulus in 11 young adults. An adaptive optics system induced 2D myopic or hyperopic defocus onto the stimulus, with or without correcting native peripheral ocular aberrations (adaptive optics [AO] or NoAO defocus conditions). Choroidal scans were captured using Heidelberg Spectralis OCT at baseline, exposure (10, 20, and 30 minutes), and recovery phases (4, 8, and 15 minutes). Neural network-based automated MATLAB segmentation program measured PChT changes from OCT scans, and statistical analysis evaluated the effects of different optical conditions over time. Results: During the exposure phase, NoAO myopic and hyperopic defocus conditions exhibited distinct bidirectional PChT alterations, showing average thickening (10.0 ± 5.3 µm) and thinning (-9.1 ± 5.5 µm), respectively. In contrast, induced AO defocus conditions did not demonstrate a significant change from baseline. PChT recovery to baseline occurred for all conditions. The unexposed fovea did not show any significant ChT change, indicating a localized ChT response to retinal blur. Conclusions: We discovered that the PChT response serves as a marker for detecting peripheral retinal myopic and hyperopic defocus blur, especially in the presence of peripheral aberrations. These findings highlight the significant role of peripheral oriented blur in cueing peripheral defocus sign detection.


Asunto(s)
Hiperopía , Miopía , Adulto Joven , Humanos , Miopía/diagnóstico , Hiperopía/diagnóstico , Coroides , Retina , Fóvea Central , Refracción Ocular
15.
Optom Vis Sci ; 90(4): 314-23, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23478630

RESUMEN

PURPOSE: To investigate the feasibility of correcting ocular higher order aberrations (HOAs) in keratoconus (KC) using wavefront-guided optics in a scleral lens prosthetic device (SLPD). METHODS: Six advanced KC patients (11 eyes) were fitted with an SLPD with conventional spherical optics. A custom-made Shack-Hartmann wavefront sensor was used to measure aberrations through a dilated pupil wearing the SLPD. The position of SLPD, that is, horizontal and vertical decentration relative to the pupil and rotation were measured and incorporated into the design of the wavefront-guided optics for the customized SLPD. A submicron-precision lathe created the designed irregular profile on the front surface of the device. The residual aberrations of the same eyes wearing the SLPD with wavefront-guided optics were subsequently measured. Visual performance with natural mesopic pupil was compared between SLPDs having conventional spherical and wavefront-guided optics by measuring best-corrected high-contrast visual acuity and contrast sensitivity. RESULTS: Root mean square of HOA in the 11 eyes wearing conventional SLPD with spherical optics was 1.17 ± 0.57 µm for a 6-mm pupil. Higher order aberrations were effectively corrected by the customized SLPD with wavefront-guided optics, and root mean square was reduced 3.1 times on average to 0.37 ± 0.19 µm for the same pupil. This correction resulted in significant improvement of 1.9 lines in mean visual acuity (p < 0.05). Contrast sensitivity was also significantly improved by factors of 2.4, 1.8, and 1.4 on average for 4, 8, and 12 cycles/degree, respectively (p < 0.05 for all frequencies). Although the residual aberration was comparable to that of normal eyes, the average visual acuity in logMAR with the customized SLPD was 0.21, substantially worse than normal acuity. CONCLUSIONS: The customized SLPD with wavefront-guided optics corrected the HOA of advanced KC patients to normal levels and improved their vision significantly.


Asunto(s)
Lentes de Contacto , Queratocono/terapia , Refracción Ocular , Esclerótica/fisiopatología , Adulto , Topografía de la Córnea , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Persona de Mediana Edad , Diseño de Prótesis , Esclerótica/patología , Agudeza Visual
16.
Biomed Opt Express ; 14(8): 4190-4204, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37799675

RESUMEN

The quantitative evaluation of peripheral ocular optics is essential in both myopia research and the investigation of visual performance in people with normal and compromised central vision. We have developed a widefield scanning wavefront sensor (WSWS) capable of multidirectional scanning while maintaining natural central fixation at the primary gaze. This Shack-Hartmann-based WSWS scans along any retinal meridian by using a unique scanning method that involves the concurrent operation of a motorized rotary stage (horizontal scan) and a goniometer (vertical scan). To showcase the capability of the WSWS, we tested scanning along four meridians including a 60° horizontal, 36° vertical, and two 36° diagonal scans, each completed within a time frame of 5 seconds.

17.
J Neurosci ; 31(27): 9814-8, 2011 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-21734272

RESUMEN

Human stereopsis, the perception of depth from differences in the two eyes' images, is very precise: image differences smaller than a single photoreceptor can be converted into a perceived difference in depth. To better understand what determines this precision, we examined how the eyes' optics affects stereo resolution. We did this by comparing performance with normal, well-focused optics and with optics improved by eliminating chromatic aberration and correcting higher-order aberrations. We first measured luminance contrast sensitivity in both eyes and showed that we had indeed improved optical quality significantly. We then measured stereo resolution in two ways: by finding the finest corrugation in depth that one can perceive, and by finding the smallest disparity one can perceive as different from zero. Our optical manipulation had no effect on stereo performance. We checked this by redoing the experiments at low contrast and again found no effect of improving optical quality. Thus, the resolution of human stereopsis is not limited by the optics of the well-focused eye. We discuss the implications of this remarkable finding.


Asunto(s)
Acomodación Ocular/fisiología , Atención/fisiología , Percepción de Profundidad/fisiología , Óptica y Fotónica , Análisis de Varianza , Sensibilidad de Contraste/fisiología , Femenino , Humanos , Masculino , Estimulación Luminosa , Psicofísica , Tiempo de Reacción , Visión Binocular/fisiología
18.
Ocul Surf ; 10(1): 43-50, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22330058

RESUMEN

The clinical tests used to assess tear film and diagnose dry eye are invasive and produce results that are different from natural tear characteristics. There is a need to objectively and noninvasively assess tear parameters under controlled environmental circumstances to refine dry eye diagnosis and therapy. We have developed multimodal tear imaging systems integrated in a chamber in which individual environmental factors can be precisely varied to investigate their impacts on tear parameters. With the custom-built high-resolution wavefront sensor combined with placido disc, it is possible to objectively detect two-dimensional tear breakups in real time and evaluate its impact on visual quality. Micrometer ultra-high resolution optical coherence tomography (OCT) enables us to quantify thickness and volume of the tear over the cornea and tear menisci. The ocular surface imaging ellipsometer uses polarized illumination from which both the lipid refractive index and thickness can be measured at a very high resolution. Using an enhanced thermal camera, we measure the ocular surface temperature noninvasively, which makes it possible to study spatial and temporal changes in tear evaporation. The multimodal deployment of these four components in the controlled chamber will assist in better differentiating the various clinical dry eye entities and will lead to the development of specific dry eye treatments.


Asunto(s)
Síndromes de Ojo Seco/diagnóstico , Lágrimas/fisiología , Síndromes de Ojo Seco/fisiopatología , Humanos
19.
Biomed Opt Express ; 13(9): 4528-4538, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36187236

RESUMEN

An adaptive optics (AO) system was used to investigate the effect of long-term neural adaptation to the habitual optical profile on neural contrast sensitivity in pseudophakic eyes after the correction of all aberrations, defocus, and astigmatism. Pseudophakic eyes were assessed at 4 and 8 months postoperatively for changes in visual performance. Visual benefit was observed in all eyes at all spatial frequencies after AO correction. The average visual benefit across spatial frequencies was higher in the pseudophakic group (3.31) at 4 months postoperatively compared to the normal group (2.41). The average contrast sensitivity after AO correction in the pseudophakic group improved by a factor of 1.73 between 4 and 8 months postoperatively. Contrast sensitivity in pseudophakic eyes was poorer, which could be attributed to long-term adaptation to the habitual optical profiles before the cataract surgery, in conjunction with age-related vision loss. Improved visual performance in pseudophakic eyes suggests that the aged neural system can be re-adapted for altered ocular optics.

20.
Invest Ophthalmol Vis Sci ; 63(11): 26, 2022 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-36306143

RESUMEN

Purpose: The purpose of this study was to locate the visual axis and evaluate its correlation with the Stiles-Crawford effect (SCE) peak. Methods: Ten young, healthy individuals (20 eyes) were enrolled. An optical system was developed to locate the visual axis and measure SCE. To locate the visual axis, 2 small laser spots at 450 nm and 680 nm were co-aligned and delivered to the retina. The participants were asked to move a translatable pinhole until these spots were perceived to overlap each other. The same system assessed SCE at 680 nm using a bipartite, 2-channel (reference and test) Maxwellian-view optical system. The peak positions were estimated using a two-dimensional Gaussian fitting function and correlated with the visual axis positions. Results: Both the visual axis (x = 0.24 ± 0.35 mm, y = -0.16 ± 0.34 mm) and the SCE peak (x = 0.27 ± 0.35 mm, y = -0.15 ± 0.31 mm) showed intersubject variability among the cohort. The SCE peak positions were highly correlated in both the horizontal and vertical meridians to the visual axes (R2 = 0.98 and 0.96 for the x and y coordinates, respectively). Nine of the 10 participants demonstrated mirror symmetry for the coordinates of the visual axis and the SCE peak between the eyes (R2 = 0.71 for the visual axis and 0.76 for the SCE peak). Conclusions: The visual axis and SCE peak locations varied among the participants; however, they were highly correlated with each other for each individual. These findings suggest a potential mechanism underlying the foveal cone photoreceptor alignment.


Asunto(s)
Fóvea Central , Células Fotorreceptoras Retinianas Conos , Humanos , Estudios de Cohortes , Retina , Luz