Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Br J Clin Pharmacol ; 85(4): 746-761, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30597603

RESUMEN

AIMS: Various mycophenolate mofetil (MMF) population pharmacokinetic (popPK) models have been developed to describe its PK characteristics and facilitate its optimal dosing in adult kidney transplant recipients co-administered with tacrolimus. However, the external predictive performance has been unclear. Thus, this study aimed to comprehensively evaluate the external predictability of published MMF popPK models in such populations and investigate the potential influencing factors. METHODS: The external predictability of qualified popPK models was evaluated using an independent dataset. The evaluation included prediction- and simulation-based diagnostics, and Bayesian forecasting. In addition, factors influencing model predictability, especially the impact of structural models, were investigated. RESULTS: Fifty full PK profiles from 45 patients were included in the evaluation dataset and 11 published popPK models were identified and evaluated. In prediction-based diagnostics, the prediction error within ±30% was less than 50% in most published models. The prediction- and variability-corrected visual predictive check and posterior predictive check showed large discrepancies between the observations and simulations in most models. Moreover, the normalized prediction distribution errors of all models did not follow a normal distribution. Bayesian forecasting demonstrated an improvement in the model predictability. Furthermore, the predictive performance of two-compartment (2CMT) models incorporating the enterohepatic circulation (EHC) process was not superior to that of conventional 2CMT models. CONCLUSIONS: The published models showed large variability and unsatisfactory predictive performance, which indicated that therapeutic drug monitoring was necessary for MMF clinical application. Further studies incorporating potential covariates need to be conducted to investigate the key factors influencing model predictability of MMF.


Asunto(s)
Rechazo de Injerto/prevención & control , Inmunosupresores/farmacocinética , Trasplante de Riñón/efectos adversos , Modelos Biológicos , Ácido Micofenólico/farmacocinética , Tacrolimus/farmacocinética , Adulto , Anciano , Área Bajo la Curva , Conjuntos de Datos como Asunto , Relación Dosis-Respuesta a Droga , Interacciones Farmacológicas , Monitoreo de Drogas/métodos , Quimioterapia Combinada , Femenino , Rechazo de Injerto/inmunología , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Ácido Micofenólico/administración & dosificación , Tacrolimus/administración & dosificación , Adulto Joven
2.
Pediatr Transplant ; 21(2)2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28042690

RESUMEN

Early graft loss and poor graft function limit the use of kidneys from infant donors. Six en bloc kidney transplantations were performed from infant donors younger than 10 months into pediatric recipients between November 2012 and September 2015 at our center. We retrospectively analyzed recipient and donor demographics, surgery procedures, complications, graft function and size, and patient and graft survival with a follow-up of 6-39 months (median 15.5 months). Donor age ranged from 1 to 10 months with weight ranging from 3.5 to 10 kg. Recipient age ranged from 10 to 16 years with weight ranging from 30 to 39 kg. One kidney was removed due to arterial thrombosis during surgery, while the other kidney of this en bloc graft remained viable. Urine leak followed by bilateral ureteral obstruction occurred in one recipient. All of the recipients showed immediate graft function. The size of the en bloc kidney increased from 4.2±0.6 cm to 7.6±0.6 cm 6 months after surgery. Patient and graft survival were both 100% at the last follow-up. Our results show that en bloc kidney transplantation from infant donors younger than 10 months into pediatric recipients is effective under the condition of experienced surgical techniques and perioperative management.


Asunto(s)
Trasplante de Riñón/métodos , Insuficiencia Renal/cirugía , Donantes de Tejidos , Adolescente , Arterias/fisiopatología , Peso Corporal , Niño , Femenino , Tasa de Filtración Glomerular , Supervivencia de Injerto , Humanos , Inmunosupresores/uso terapéutico , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Trombosis/etiología , Resultado del Tratamiento , Obstrucción Ureteral/etiología
3.
Chin Med J (Engl) ; 130(1): 23-31, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28051019

RESUMEN

BACKGROUND: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. METHODS: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann-Whitney U-test was used for analysis. RESULTS: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P= 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P= 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P= 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P= 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. CONCLUSIONS: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions.


Asunto(s)
Simulación por Computador , Trasplante de Riñón/efectos adversos , Obstrucción de la Arteria Renal/cirugía , Adolescente , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Prótesis Vascular , Femenino , Hemodinámica , Humanos , Hidrodinámica , Masculino , Persona de Mediana Edad , Modelos Teóricos , Obstrucción de la Arteria Renal/fisiopatología , Estrés Mecánico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA