RESUMEN
Large-ring cyclodextrins (CD) are cyclic glucans composed of 9 or more α-1,4-linked glucose units. They are minor side products of bacterial glucanotransferases (CGTases, ECâ 2.4.1.19) and have previously been available only in very small amounts for studies of their properties in supramolecular complex formation reactions. We engineered a CGTase to synthesize mainly large-ring CD facilitating their preparation in larger amounts. By reversed phase chromatography, we obtained single CD samples composed of 10 to 12 glucose units (CD10, CD11, and CD12) with a purity of >90 %. Their identity was confirmed by high resolution mass spectrometry and fragmentation analysis. We demonstrated the non-toxicity of CD10-CD12 for human cell lines by a cell proliferation assay and impedimetric monitoring. We then showed that CD10 and CD11 are efficient chiral selectors for the capillary electrophoretic separation of the enantiomeric pharmaceuticals fluvastatin, mefloquine, carvedilol, and primaquine.
Asunto(s)
Ciclodextrinas/química , Preparaciones Farmacéuticas/química , Bacillus/enzimología , Proteínas Bacterianas/metabolismo , Línea Celular , Supervivencia Celular/efectos de los fármacos , Ciclodextrinas/metabolismo , Electroforesis Capilar , Fluvastatina/síntesis química , Fluvastatina/aislamiento & purificación , Fluvastatina/farmacología , Glucosiltransferasas/metabolismo , Humanos , Mefloquina/síntesis química , Mefloquina/aislamiento & purificación , Mefloquina/farmacología , Preparaciones Farmacéuticas/síntesis química , Preparaciones Farmacéuticas/aislamiento & purificación , Espectrometría de Masa por Ionización de Electrospray , EstereoisomerismoRESUMEN
For miniaturization and integration of chemical synthesis and analytics on small length scales, the development of complex lab-on-chip (LOC) systems is in the focus of many current research projects. While application specific synthesis and analytic modules and LOC devices are widely described, the combination and integration of different modules is intensively investigated. Problems for in-line processes such as solvent incompatibilities, e.g., for a multistep synthesis or the combination of an organic drug synthesis with a cell-based biological activity testing system, require a solvent exchange between serialized modules. Here, we present a continuously operating microfluidic solvent exchanger based on the principle of free-flow electrophoresis for miscible organic/aqueous fluids. We highlight a proof-of-principle and describe the working principle for the model compound fluorescein, where the organic solvent DMSO is exchanged against an aqueous buffer. The DMSO removal performance could be significantly increased to 95% by optimization of the microfluidic layout. Moreover, the optimization of the inlet flow ratio resulted in a minimized dilution factor of 5, and we were able to demonstrate that a reduction of the supporting instrumentation is possible without a significant decrease of the DMSO removal performance. Finally, the compatibility of the developed solvent exchanger for cell based downstream applications was proven. The impedimetric monitoring of HEK293A cells in a continuously operating microfluidic setup revealed no adverse effects of the residual DMSO after the solvent replacement. Our solvent exchanger device demonstrates the power of micro-free-flow electrophoresis not only as a powerful technique for separation and purification of compound mixtures but also for solvent replacement.
RESUMEN
The analysis of receptor activity, especially in its native cellular environment, has always been of great interest to evaluate its intrinsic but also downstream biological activity. An important group of cellular receptors are ion channels. Since they are involved in a broad range of crucial cell functions, they represent important therapeutic targets. Thus, novel analytical techniques for the quantitative monitoring and screening of biological receptor activity are of great interest. In this context, we developed an impedance spectroscopy-based label-free and non-invasive monitoring system that enabled us to analyze the activation of the transient receptor potential channel Vanilloid 1 (TRPV1) in detail. TRPV1 channel activation by capsaicin resulted in a reproducible impedance decrease. Moreover, concentration response curves with an EC50 value of 0.9 µM could be determined. Control experiments with non TRPV1 channel expressing HEK cells as well as experiments with the TRPV1 channel blocker ruthenium red validated the specificity of the observed impedance decrease. More strikingly, through correlative studies with a cytoskeleton restructuring inhibitor mixture and equivalent circuit analysis of the acquired impedance spectra, we could quantitatively discriminate between the direct TRPV1 channel activation and downstream-induced biological effects. In summary, we developed a quantitative impedimetric monitoring system for the analysis of TRPV1 channel activity as well as downstream-induced biological activity in living cells. It has the capabilities to identify novel ion channel activators as well as inhibitors for the TRPV1 channel but could also easily be applied to other ion channel-based receptors.
Asunto(s)
Capsaicina/farmacología , Espectroscopía Dieléctrica/métodos , Canales Catiónicos TRPV/metabolismo , Electrodos , Células HEK293 , Humanos , Reproducibilidad de los Resultados , Rojo de Rutenio/farmacología , Sensibilidad y Especificidad , Canales Catiónicos TRPV/antagonistas & inhibidoresRESUMEN
Three-dimensional (3D) in vitro cell culture models serve as valuable tools for accurately replicating cellular microenvironments found in vivo. While cell culture technologies are rapidly advancing, the availability of non-invasive, real-time, and label-free analysis methods for 3D cultures remains limited. To meet the demand for higher-throughput drug screening, there is a demanding need for analytical methods that can operate in parallel. Microelectrode systems in combination with microcavity arrays (MCAs), offer the capability of spatially resolved electrochemical impedance analysis and field potential monitoring of 3D cultures. However, the fabrication and handling of small-scale MCAs have been labour-intensive, limiting their broader application. To overcome this challenge, we have established a process for creating MCAs in a standard 96-well plate format using high-precision selective laser etching. In addition, to automate and ensure the accurate placement of 3D cultures on the MCA, we have designed and characterized a plug-in tool using SLA-3D-printing. To characterize our new 96-well plate MCA-based platform, we conducted parallel analyses of human melanoma 3D cultures and monitored the effect of cisplatin in real-time by impedance spectroscopy. In the following we demonstrate the capabilities of the MCA approach by analysing contraction rates of human pluripotent stem cell-derived cardiomyocyte aggregates in response to cardioactive compounds. In summary, our MCA system significantly expands the possibilities for label-free analysis of 3D cell and tissue cultures, offering an order of magnitude higher parallelization capacity than previous devices. This advancement greatly enhances its applicability in real-world settings, such as drug development or clinical diagnostics.
Asunto(s)
Técnicas Biosensibles , Humanos , Miocitos Cardíacos , Técnicas de Cultivo de Célula/métodos , Técnicas de Cultivo Tridimensional de Células , Espectroscopía DieléctricaRESUMEN
In recent decades, significant progress has been made in the treatment of heart diseases, particularly in the field of personalized medicine. Despite the development of genetic tests, phenotyping and risk stratification are performed based on clinical findings and invasive in vivo techniques, such as stimulation conduction mapping techniques and programmed ventricular pacing. Consequently, label-free non-invasive in vitro functional analysis systems are urgently needed for more accurate and effective in vitro risk stratification, model-based therapy planning, and clinical safety profile evaluation of drugs. To overcome these limitations, a novel multilayer high-density microelectrode array (HD-MEA), with an optimized configuration of 512 sensing and 4 pacing electrodes on a sensor area of 100 mm2, was developed for the bioelectronic detection of re-entry arrhythmia patterns. Together with a co-developed front-end, we monitored label-free and in parallel cardiac electrophysiology based on field potential monitoring and mechanical contraction using impedance spectroscopy at the same microelectrode. In proof of principle experiments, human induced pluripotent stem cell (hiPS)-derived cardiomyocytes were cultured on HD-MEAs and used to demonstrate the sensitive quantification of contraction strength modulation by cardioactive drugs such as blebbistatin (IC50 = 4.2 µM), omecamtiv and levosimendan. Strikingly, arrhythmia-typical rotor patterns (re-entry) can be induced by optimized electrical stimulation sequences and detected with high spatial resolution. Therefore, we provide a novel cardiac re-entry analysis system as a promising reference point for diagnostic approaches based on in vitro assays using patient-specific hiPS-derived cardiomyocytes.
Asunto(s)
Técnicas Biosensibles , Células Madre Pluripotentes Inducidas , Humanos , Microelectrodos , Arritmias Cardíacas/diagnóstico , Miocitos Cardíacos/fisiologíaRESUMEN
Three-dimensional cell models represent the native in vivo situation more closely than two-dimensional cultures and are therefore preferred today for in vitro studies. In this context, there is a great demand for fast, non-invasive, real-time, and label-free methods that are capable for detailed analyses of three-dimensional cultures. To characterize heterogeneous cultures or to detect localized drug effects, a measurement method such as impedance spectroscopy in combination with microcavity arrays (MCAs) is desirable, which additionally offers spatial resolution. To overcome these limitations of the previously described MCA based on opaque silicon substrates and a square shape with four measurement electrodes imposed by the crystal structure, we used the selective laser etching (SLE) method to fabricate microcavities in fused silica and borosilicate glass without geometric constraints. We successfully developed MCAs with variable base including up to eight measurement electrodes in one cavity, which allows the increase in the number of electrode combinations to improve spatial resolution. In addition, we integrated a central cone electrode at the cavity bottom to extend the spatial resolution on the z-axis. To demonstrate the capability of the MCAs, we used MDA-HB-231 spheroids with an enclosed glass sphere to show that the heterogeneity of the model is evident in the relative impedance spectra. Analyses on various cell spheroids highlight the broad applicability of glass MCAs. In conclusion, our SLE-fabricated MCA clearly improve bioelectronic analyses of cellular changes in heterogeneous 3D models. Thus, bioelectronic analysis of electrophysiologically active cells and tumor biopsy samples could significantly benefit from our development.
Asunto(s)
Técnicas Biosensibles , Técnicas Biosensibles/métodos , Espectroscopía Dieléctrica , Impedancia Eléctrica , Electrodos , Esferoides CelularesRESUMEN
Miniaturization and integration of chemical reactions into fluidic systems in combination with product purification or buffer exchange can reduce the amount of solvents and reactants required while increasing synthesis efficiency. A critical step is the regulation of flow rates to realize optimal synthesis conditions and high purification rates, so real-time, label-free monitoring is required in methods such as free-flow electrophoresis. Optical detection methods are widely used, but they often have complex excitation and detection setups that are disadvantageous for point-of-care applications. The method we have chosen is electrochemical impedance spectroscopy for detecting charged compounds in aqueous buffers with low ionic strength. Propranolol was selected for proof of concept and was separated from the organic solvent and the precursor oxirane by free-flow electrophoresis. For this purpose, electrode structures were fabricated in microfluidic channels by photolithographic lift-off technique and optimized in terms of positioning, electrode size and distance for sensitive detection, and quantification of propranolol in the nanomolar range. It is also noteworthy that the organic solvent dimethyl sulfoxide (DMSO) could be detected and quantified by an increased impedance magnitude. Subsequently, the optimized interdigital electrode structures were integrated into the outlet channels of the electrophoretic separation chamber to monitor the various outgoing fluidic streams and provide in-line control of the fluidic flows for the purification step. In conclusion, we can provide a microfluidic chip to monitor the separation efficiency of a substance mixture during free-flow electrophoresis without the need of complex analytical techniques using electrochemical impedance spectroscopy.
Asunto(s)
Técnicas Analíticas Microfluídicas , Técnicas Analíticas Microfluídicas/métodos , Espectroscopía Dieléctrica , Propranolol , Electroforesis , ElectrodosRESUMEN
Insufficient endothelialization of cardiovascular devices is a high-risk factor for implant failure. Presentation of extracellular matrix (ECM)-derived coatings is a well-known strategy to improve implant integration. However, the complexity of the system is challenging and strategies for applying multifunctionality are required. Here, we engineered mussel-derived surface-binding peptides equipped with integrin (c[RGDfK]) and proteoglycan binding sites (FHRRIKA) for enhanced endothelialization. Surface-binding properties of the platform containing l-3,4-dihydroxyphenylalanine (DOPA) residues were confirmed for hydrophilized polycaprolactone-co-lactide scaffolds as well as for glass and polystyrene. Further, heparin and the heparin-binding angiogenic factors VEGF, FGF-2 and CXCL12 were immobilized onto the peptide in a modular assembly. Presentation of bioactive peptides greatly enhanced human umbilical vein endothelial cell (HUVEC) adhesion and survival under static and fluidic conditions. In subsequent investigations, peptide-heparin-complexes loaded with CXCL12 or VEGF had an additional increasing effect on cell viability, differentiation and migration. Finally, hemocompatibility of the coatings was ensured. This study demonstrates that coatings combining adhesion peptides, glycosaminoglycans and modulators are a versatile tool to convey ECM-inspired multifunctionality to biomaterials and efficiently promote their integration.
Asunto(s)
Citocinas/administración & dosificación , Células Endoteliales de la Vena Umbilical Humana/citología , Levodopa/química , Péptidos/administración & dosificación , Implantes Absorbibles , Animales , Prótesis Vascular , Diferenciación Celular , Línea Celular , Proliferación Celular , Supervivencia Celular/efectos de los fármacos , Citocinas/farmacología , Matriz Extracelular , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Humanos , Integrinas/química , Ratones , Péptidos/química , Péptidos/farmacología , Proteoglicanos/química , Propiedades de SuperficieRESUMEN
Understanding of cell migration and spreading out of tumor tissue is of great interest concerning the mechanism and causes of tumor malignancy and metastases. Although there are methods available for studying cell migration on monolayer cell cultures like transwell assays, novel techniques for monitoring cell spreading out of 3D organoids or tumor tissue samples are highly required. In this context, we developed an innovative high-dense microelectrode array for impedimetric monitoring of cell migration from 3D tumor cultures. For a proof of concept, a strongly migrating breast cancer cell line (MDA-MB-231) and two malignant melanoma cell lines (T30.6.9, T12.8.10ZII) were used for generating viable micro-tumor models. The migration propensity was determined by impedimetric monitoring over 144 hours, correlated by microscopy and validated by transwell assays. The impedimetric analysis of covered electrodes and the relative impedance maximum values revealed extended information regarding the contribution of proliferative effects. More strikingly, using reference populations of mitomycin C treated spheroids where proliferation was suppressed, distinction of proliferation and migration was possible. Therefore, our high-dense microelectrode array based impedimetric migration monitoring has the capability for an automated quantitative analysis system that can be easily scaled up as well as integrated in lab on chip devices.
Asunto(s)
Neoplasias de la Mama/patología , Movimiento Celular/fisiología , Melanoma/patología , Línea Celular Tumoral , Proliferación Celular/fisiología , Impedancia Eléctrica , Femenino , Humanos , MicroelectrodosRESUMEN
Lab-on-a-chip devices that combine, e.g. chemical synthesis with integrated on-chip analytics and multi-compartment organ-on-a-chip approaches, are a fast and attractive evolving research area. While integration of appropriate cell models in microfluidic setups for monitoring the biological activity of synthesis products or test compounds is already in focus, the integration of label-free bioelectronic analysis techniques is still poorly realized. In this context, we investigated the capabilities of impedance spectroscopy as a non-destructive real-time monitoring technique for adherent cell models in a microfluidic setup. While an initial adaptation of a microelectrode array (MEA) layout from a static setup revealed clear restrictions in the application of impedance spectroscopy in a microfluidic chip, we could demonstrate the advantage of a FEM simulation based rational MEA layout optimization for an optimum electrical field distribution within microfluidic structures. Furthermore, FEM simulation based analysis of shear stress and time-dependent test compound distribution led to identification of an optimal flow rate. Based on the simulation derived optimized microfluidic MEA, comparable impedance spectra characteristics were achieved for HEK293A cells cultured under microfluidic and static conditions. Furthermore, HEK293A cells expressing Y1 receptors were used to successfully demonstrate the capabilities of impedimetric monitoring of cellular alterations in the microfluidic setup. More strikingly, the maximum impedimetric signal for the receptor activation was significantly increased by a factor of 2.8. Detailed investigations of cell morphology and motility led to the conclusion that cultivation under microfluidic conditions could lead to an extended and stabilized cell-electrode interface.