Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Medicina (Kaunas) ; 55(3)2019 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-30862115

RESUMEN

Lung hyperinflation is a main determinant of dyspnoea in patients with chronic obstructive pulmonary disease (COPD). Surgical or bronchoscopic lung volume reduction are the most efficient therapeutic approaches for reducing hyperinflation in selected patients with emphysema. We here report the case of a 69-year old woman with COPD (GOLD stage 3-D) referred for lung volume reduction. She complained of persistent disabling dyspnoea despite appropriate therapy. Chest imaging showed marked emphysema heterogeneity as well as severe hyperinflation of the right lower lobe. She was deemed to be a good candidate for bronchoscopic treatment with one-way endobronchial valves. In the absence of interlobar collateral ventilation, 2 endobronchial valves were placed in the right lower lobe under general anaesthesia. The improvement observed 1 and 3 months after the procedure was such that the patient no longer met the pulmonary function criteria for COPD. The benefit persisted after 3 years.


Asunto(s)
Neumonectomía/rehabilitación , Prótesis e Implantes/efectos adversos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/rehabilitación , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/cirugía , Actividades Cotidianas , Anciano , Broncoscopía , Disnea/diagnóstico por imagen , Disnea/fisiopatología , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/cirugía , Pruebas de Función Respiratoria , Fumadores , Tomógrafos Computarizados por Rayos X , Resultado del Tratamiento
3.
Can Respir J ; 2021: 8822591, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33791047

RESUMEN

Purpose: Airway stenting offers good palliation and improves the quality of life in patients with inoperable bronchotracheal stenosis. However, in some cases, the management of stenting can be life-threatening. Hence, a strategy for maintaining oxygenation and hemodynamic stability should be anticipated to avoid critical situations. Herein, we report the use of extracorporeal membrane oxygenation (ECMO) in bronchotracheal stenting management to secure oxygenation and facilitate interventions. Methods: We retrospectively reviewed all patients who underwent rigid bronchoscopy under ECMO support for the management of bronchotracheal stenting at CHU UCL Namur hospital (Belgium), between January 2009 and December 2019. Results: We included 14 bronchoscopy cases performed on 11 patients (3 patients underwent 2 bronchoscopies) in this study; 12 were performed on males and 2 on females. The median age was 54 years. There were 11 benign and 3 malignant etiologies for the central airway obstruction/stenosis. Eight cases were supported by venovenous ECMO and six by venoarterial ECMO. The median ECMO time was 267 minutes. The weaning of ECMO support was successful in all cases. In most cases, the procedures were performed effectively and safely. Only two local complications caused by the cannulation of ECMO were reported, and anticoagulation was adapted to avoid bleeding at the operating site and clot formation in the system. Conclusion: Elective ECMO support was helpful and safe for the high-risk management of bronchotracheal stenting with rigid bronchoscopy and was not associated with any additional significant complications.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Broncoscopía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Stents
4.
Can Respir J ; 2018: 6202750, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29951159

RESUMEN

[This corrects the article DOI: 10.1155/2016/8085216.].

5.
Can Respir J ; 14(4): 235-7, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17551600

RESUMEN

A case of pulmonary Langerhans cell histiocytosis, proved by both lung high-resolution computed tomography and lung biopsy, is described. Following smoking cessation, lung nodules and cysts gradually disappeared on serial computed tomography scans, with complete clearance of the lesions after 12 months. The role of tobacco smoking is discussed, in detail, against the background of the literature.


Asunto(s)
Histiocitosis de Células de Langerhans/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Remisión Espontánea , Cese del Hábito de Fumar , Tomografía Computarizada por Rayos X
6.
Can Respir J ; 2016: 8085216, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27777507

RESUMEN

Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., China). were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation), and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent's tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%), migration (30%), and sputum retention (15%). Fifty-five % of the stents (11/20) had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease.


Asunto(s)
Anastomosis Quirúrgica , Intubación Intratraqueal , Trasplante de Pulmón , Neumonectomía , Complicaciones Posoperatorias/cirugía , Stents Metálicos Autoexpandibles , Estenosis Traqueal/cirugía , Adulto , Anciano , Femenino , Tejido de Granulación , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
7.
Int J Antimicrob Agents ; 44(3): 209-17, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25123808

RESUMEN

The correlation between Streptococcus pneumoniae serotypes, biofilm production, antibiotic susceptibility and drug efflux in isolates from patients suffering from acute exacerbations of chronic bronchitis (AECB) remains largely unexplored. Using 101 isolates collected from AECB patients for whom partial (n=51) or full (n=50) medical details were available, we determined serotypes (ST)/serogroups (SG) (Quellung reaction), antibiotic susceptibility patterns [MIC (microdilution) using EUCAST and CLSI criteria] and ability to produce biofilm in vitro (10-day model; crystal violet staining). The majority of patients were 55-75 years old and <5% were vaccinated against S. pneumoniae. Moreover, 54% showed high severity scores (GOLD 3-4), and comorbidities were frequent including hypertension (60%), cancer (24%) and diabetes (20%). Alcohol and/or tobacco dependence was >30%. Isolates of SG6-11-15-23, known for large biofilm production and causing chronic infections, were the most prevalent (>15% each), but other isolates also produced biofilm (SG9-18-22-27 and ST8-20 being most productive), except SG7, SG29 and ST5 (<2% of isolates each). Resistance (EUCAST breakpoints) was 8-13% for amoxicillin and cefuroxime, 35-39% for macrolides, 2-8% for fluoroquinolones and 2% for telithromycin. ST19A isolates showed resistance to all antibiotics, ST14 to all except moxifloxacin, and SG9 and SG19 to all except telithromycin, moxifloxacin and ceftriaxone (SG19 only). Solithromycin and telithromycin MICs were similar. No correlation was observed between biofilm production and MIC or efflux (macrolides, fluoroquinolones). S. pneumoniae serotyping may improve AECB treatment by avoiding antibiotics with predictable low activity, but it is not predictive of biofilm production.


Asunto(s)
Antibacterianos/farmacología , Biopelículas/crecimiento & desarrollo , Bronquitis Crónica/microbiología , Infecciones Neumocócicas/microbiología , Streptococcus pneumoniae/efectos de los fármacos , Streptococcus pneumoniae/fisiología , Anciano , Antibacterianos/metabolismo , Transporte Biológico Activo , Farmacorresistencia Bacteriana , Femenino , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Serogrupo , Streptococcus pneumoniae/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA