Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.455
Filtrar
Más filtros

Intervalo de año de publicación
1.
Physiol Rev ; 100(4): 1467-1525, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32191560

RESUMEN

Impairments of vision and hearing are highly prevalent conditions limiting the quality of life and presenting a major socioeconomic burden. For a long time, retinal and cochlear disorders have remained intractable for causal therapies, with sensory rehabilitation limited to glasses, hearing aids, and electrical cochlear or retinal implants. Recently, the application of gene therapy and optogenetics to eye and ear has generated hope for a fundamental improvement of vision and hearing restoration. To date, one gene therapy for the restoration of vision has been approved, and ongoing clinical trials will broaden its application including gene replacement, genome editing, and regenerative approaches. Moreover, optogenetics, i.e., controlling the activity of cells by light, offers a more general alternative strategy. Over little more than a decade, optogenetic approaches have been developed and applied to better understand the function of biological systems, while protein engineers have identified and designed new opsin variants with desired physiological features. Considering potential clinical applications of optogenetics, the spotlight is on the sensory systems, particularly the eye and ear. Multiple efforts have been undertaken to restore lost or hampered function in the eye and ear. Optogenetic stimulation promises to overcome fundamental shortcomings of electrical stimulation, namely, poor spatial resolution and cellular specificity, and accordingly to deliver more detailed sensory information. This review aims to provide a comprehensive reference on current gene therapeutic and optogenetic research relevant to the restoration of hearing and vision. We will introduce gene-therapeutic approaches and discuss the biotechnological and optoelectronic aspects of optogenetic hearing and vision restoration.


Asunto(s)
Pérdida Auditiva/terapia , Trastornos de la Visión/terapia , Humanos , Optogenética , Prótesis Visuales
2.
Annu Rev Neurosci ; 42: 47-65, 2019 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-30699049

RESUMEN

The modern cochlear implant (CI) is the most successful neural prosthesis developed to date. CIs provide hearing to the profoundly hearing impaired and allow the acquisition of spoken language in children born deaf. Results from studies enabled by the CI have provided new insights into (a) minimal representations at the periphery for speech reception, (b) brain mechanisms for decoding speech presented in quiet and in acoustically adverse conditions, (c) the developmental neuroscience of language and hearing, and (d) the mechanisms and time courses of intramodal and cross-modal plasticity. Additionally, the results have underscored the interconnectedness of brain functions and the importance of top-down processes in perception and learning. The findings are described in this review with emphasis on the developing brain and the acquisition of hearing and spoken language.


Asunto(s)
Percepción Auditiva/fisiología , Implantes Cocleares , Período Crítico Psicológico , Desarrollo del Lenguaje , Animales , Trastornos de la Percepción Auditiva/etiología , Encéfalo/crecimiento & desarrollo , Implantación Coclear , Comprensión , Señales (Psicología) , Sordera/congénito , Sordera/fisiopatología , Sordera/psicología , Sordera/cirugía , Diseño de Equipo , Humanos , Trastornos del Desarrollo del Lenguaje/etiología , Trastornos del Desarrollo del Lenguaje/prevención & control , Aprendizaje/fisiología , Plasticidad Neuronal , Estimulación Luminosa
3.
Clin Microbiol Rev ; 37(2): e0010423, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38506553

RESUMEN

SUMMARYImplant-associated infections (IAIs) pose serious threats to patients and can be associated with significant morbidity and mortality. These infections may be difficult to diagnose due, in part, to biofilm formation on device surfaces, and because even when microbes are found, their clinical significance may be unclear. Despite recent advances in laboratory testing, IAIs remain a diagnostic challenge. From a therapeutic standpoint, many IAIs currently require device removal and prolonged courses of antimicrobial therapy to effect a cure. Therefore, making an accurate diagnosis, defining both the presence of infection and the involved microorganisms, is paramount. The sensitivity of standard microbial culture for IAI diagnosis varies depending on the type of IAI, the specimen analyzed, and the culture technique(s) used. Although IAI-specific culture-based diagnostics have been described, the challenge of culture-negative IAIs remains. Given this, molecular assays, including both nucleic acid amplification tests and next-generation sequencing-based assays, have been used. In this review, an overview of these challenging infections is presented, as well as an approach to their diagnosis from a microbiologic perspective.


Asunto(s)
Técnicas Microbiológicas , Infecciones Relacionadas con Prótesis , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Técnicas Microbiológicas/métodos , Bacterias/aislamiento & purificación , Bacterias/clasificación , Bacterias/genética , Laboratorios Clínicos , Técnicas de Diagnóstico Molecular/métodos
4.
Eur J Neurosci ; 59(10): 2596-2615, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38441248

RESUMEN

Auditory deprivation following congenital/pre-lingual deafness (C/PD) can drastically affect brain development and its functional organisation. This systematic review intends to extend current knowledge of the impact of C/PD and deafness duration on brain resting-state networks (RSNs), review changes in RSNs and spoken language outcomes post-cochlear implant (CI) and draw conclusions for future research. The systematic literature search followed the PRISMA guideline. Two independent reviewers searched four electronic databases using combined keywords: 'auditory deprivation', 'congenital/prelingual deafness', 'resting-state functional connectivity' (RSFC), 'resting-state fMRI' and 'cochlear implant'. Seventeen studies (16 cross-sectional and one longitudinal) met the inclusion criteria. Using the Crowe Critical Appraisal Tool, the publications' quality was rated between 65.0% and 92.5% (mean: 84.10%), ≥80% in 13 out of 17 studies. A few studies were deficient in sampling and/or ethical considerations. According to the findings, early auditory deprivation results in enhanced RSFC between the auditory network and brain networks involved in non-verbal communication, and high levels of spontaneous neural activity in the auditory cortex before CI are evidence of occupied auditory cortical areas with other sensory modalities (cross-modal plasticity) and sub-optimal CI outcomes. Overall, current evidence supports the idea that moreover intramodal and cross-modal plasticity, the entire brain adaptation following auditory deprivation contributes to spoken language development and compensatory behaviours.


Asunto(s)
Implantación Coclear , Sordera , Humanos , Sordera/fisiopatología , Implantación Coclear/métodos , Encéfalo/fisiopatología , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Red Nerviosa/fisiopatología , Red Nerviosa/diagnóstico por imagen , Imagen por Resonancia Magnética , Corteza Auditiva/fisiopatología , Corteza Auditiva/diagnóstico por imagen , Implantes Cocleares , Resultado del Tratamiento
5.
Small ; : e2307742, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38326101

RESUMEN

Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe-based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on-board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe-30Mn-1C/Pt galvanic cell model system is first investigated and high-resolution X-ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter-sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.

6.
J Transl Med ; 22(1): 120, 2024 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-38297308

RESUMEN

BACKGROUND: One of the main factors for the osseointegration of dental implants is the development of an adequate soft tissue barrier, mainly composed by collagen, which protects the implant from bacterial development. The structural features of the peri-implant collagen are influenced by the implant components and, in particular, by the type of the surface. In the clinical practice, healing abutments are characterized by smooth surfaces, named machined. Recently, a new laser technique, Synthegra, has been developed to obtain a topography-controlled surface with micrometric regular pores that seems reducing the risk of peri-implantitis. Based on this background, this study aims investigating the structural organization and spatial distribution of collagen surrounding healing abutments characterized by laser-treated and machined surfaces. METHODS: Gingiva portions surrounding custom-made healing abutments (HA), characterized by alternated laser-treated and machined surfaces, were collected and analyzed by combining Fourier Transform InfraRed Imaging (FTIRI) spectroscopy, a non-invasive and high-resolution bidimensional analytical technique, with histological and multivariate analyses. RESULTS: Masson's trichrome staining, specific for collagen, highlighted a massive presence of collagen in all the analyzed samples, evidencing a surface-related spatial distribution. The nature of collagen, investigated by the FTIRI spectroscopy, appeared more abundant close to the laser-treated surface, with a perpendicular disposition of the bundles respect to the HA; conversely, a parallel distribution was observed around the machined surface. A different secondary structure was also found, with a higher amount of triple helices and a lower quantity of random coils in collagen close to the laser treated surfaces. CONCLUSIONS: FTIRI spectroscopy demonstrates that the use of a laser treated transmucosal surface can improve the morphological organization of the peri-implant collagen, which presents a distribution more similar to that of natural teeth. TRIAL REGISTRATION: This trial is registered with ClinicalTrials.gov Identifier: (Registration Number: NCT05754970). Registered 06/03/2023, retrospectively registered, https://clinicaltrials.gov/show/NCT05754970 .


Asunto(s)
Implantes Dentales , Colágeno , Encía/patología , Rayos Láser , Oseointegración , Propiedades de Superficie , Humanos
7.
J Cardiovasc Electrophysiol ; 35(4): 747-761, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38361241

RESUMEN

INTRODUCTION: The implantation of a cardiac implantable electronic device (CIED) can have esthetic and psychological consequences on patients. We explore a heart team model for care coordination and discuss esthetic approaches for improved cosmetic outcomes in patients undergoing (CIED)-related procedures or de novo implantation. METHODS: Patients undergoing CIED surgery for approved indications between June 2015 and June 2022 were identified. Patients were included when surgical care was provided by a collaborative relationship between the primary electrophysiologist and the plastic surgeon. Patient demographics, details of the surgical procedure, information on breast implants, complications, and outcomes related to cosmesis were recorded. RESULTS: Twenty-two female patients were included in this study. The mean age was 50.2 ± 18.2 years. The mean follow-up duration was 2.2 ± 5.5 months. The top two indications for the procedure included CIED generator change (n = 9, 41%) and implantable cardioverter-defibrillator (ICD) implantation (n = 7, 32%). The most common reasons for involving plastic surgery in the procedure included surgery near breast implants (n = 10, 45%) and device displacement or discomfort (n = 8, 36%). CIED pocket position was prepectoral in 10 cases (45%), subpectoral in 11 patients (50%), and intramuscular in one patient (4.5%). The majority of the patients (20, 91%) had cosmetically acceptable results postprocedure. One patient (4.5%) had breast asymmetry on the CIED side, and another continued to have skin erosion over the CIED and leads. CONCLUSION: A heart team approach incorporating the expertize of cardiac electrophysiology and plastic surgery is essential for providing optimal care for patients with breast implants and patients requesting esthetic appeal.


Asunto(s)
Implantes de Mama , Procedimientos Quirúrgicos Cardíacos , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Implantes de Mama/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Estudios Retrospectivos
8.
J Magn Reson Imaging ; 59(5): 1514-1522, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37767980

RESUMEN

The standard of care for managing a patient with an implant is to identify the item and to assess the relative safety of scanning the patient. Because the 1.5 T MR system is the most prevalent scanner in the world and 3 T is the highest field strength in widespread use, implants typically have "MR Conditional" (i.e., an item with demonstrated safety in the MR environment within defined conditions) labeling at 1.5 and/or 3 T only. This presents challenges for a facility that has a scanner operating at a field strength below 1.5 T when encountering a patient with an implant, because scanning the patient is considered "off-label." In this case, the supervising physician is responsible for deciding whether to scan the patient based on the risks associated with the implant and the benefit of magnetic resonance imaging (MRI). For a passive implant, the MRI safety-related concerns are static magnetic field interactions (i.e., force and torque) and radiofrequency (RF) field-induced heating. The worldwide utilization of scanners operating below 1.5 T combined with the increasing incidence of patients with implants that need MRI creates circumstances that include patients potentially being subjected to unsafe imaging conditions or being denied access to MRI because physicians often lack the knowledge to perform an assessment of risk vs. benefit. Thus, physicians must have a complete understanding of the MRI-related safety issues that impact passive implants when managing patients with these products on scanners operating below 1.5 T. This monograph provides an overview of the various clinical MR systems operating below 1.5 T and discusses the MRI-related factors that influence safety for passive implants. Suggestions are provided for the management of patients with passive implants labeled MR Conditional at 1.5 and/or 3 T, referred to scanners operating below 1.5 T. The purpose of this information is to empower supervising physicians with the essential knowledge to perform MRI exams confidently and safely in patients with passive implants. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Campos Magnéticos , Prótesis e Implantes , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
9.
Muscle Nerve ; 69(2): 134-147, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38126120

RESUMEN

After an amputation, advanced prosthetic limbs can be used to interface with the nervous system and restore motor function. Despite numerous breakthroughs in the field, many of the recent research advancements have not been widely integrated into clinical practice. This review highlights recent innovations in neuromuscular implants-specifically those that interface with skeletal muscle-which could improve the clinical translation of prosthetic technologies. Skeletal muscle provides a physiologic gateway to harness and amplify signals from the nervous system. Recent surgical advancements in muscle reinnervation surgeries leverage the "bio-amplification" capabilities of muscle, enabling more intuitive control over a greater number of degrees of freedom in prosthetic limbs than previously achieved. We anticipate that state-of-the-art implantable neuromuscular interfaces that integrate well with skeletal muscle and novel surgical interventions will provide a long-term solution for controlling advanced prostheses. Flexible electrodes are expected to play a crucial role in reducing foreign body responses and improving the longevity of the interface. Additionally, innovations in device miniaturization and ongoing exploration of shape memory polymers could simplify surgical procedures for implanting such interfaces. Once implanted, wireless strategies for powering and transferring data from the interface can eliminate bulky external wires, reduce infection risk, and enhance day-to-day usability. By outlining the current limitations of neuromuscular interfaces along with potential future directions, this review aims to guide continued research efforts and future collaborations between engineers and specialists in the field of neuromuscular and musculoskeletal medicine.


Asunto(s)
Miembros Artificiales , Músculo Esquelético , Electrodos
10.
World J Urol ; 42(1): 35, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38217727

RESUMEN

PURPOSE: Past decade has seen a renewed interest in minimally invasive surgical techniques (MISTs) for management of enlarged prostate. This narrative review aims to explore newer MIST for benign prostatic hyperplasia (BPH) which are not yet integrated into established societal guidelines. METHODS: We conducted a literature search across PubMed, Google Scholar, and FDA ClinicalTrials.gov databases on June 1st, 2023, to identify studies published within the past decade exploring various MISTs for BPH. Additionally, we gathered insights from abstracts presented in meetings of professional associations and corporate websites. We broadly classified these procedures into three distinct categories: energy-based, balloon dilation, and implant/stent treatments. We collected detail information about the device, procedure details, its inclusion and exclusion criteria, and outcome. RESULTS: Our review reveals that newer energy-based MISTs include Transperineal Laser Ablation, Transurethral Ultrasound Ablation, and High-Intensity Focused Ultrasound. In the sphere of balloon dilation, Transurethral Columnar Balloon Dilation and the Optilume BPH Catheter System were gaining momentum. The noteworthy implants/stents that are on horizon include Butterfly Prostatic Retraction Device, Urocross Expander System, Zenflow Spring System, and ProVee Urethral Expander System. CONCLUSION: The exploration of various MISTs reflects ongoing efforts to enhance patient care and address limitations of existing treatments. This review provides a bird-eye view and valuable insights for urologists and researchers seeking to navigate the dynamic landscape of MISTs in the quest for effective and minimally invasive solutions for enlarged prostates.


Asunto(s)
Hiperplasia Prostática , Resección Transuretral de la Próstata , Masculino , Humanos , Hiperplasia Prostática/cirugía , Próstata/cirugía , Resección Transuretral de la Próstata/métodos , Prostatectomía/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos , Stents
11.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658140

RESUMEN

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Asunto(s)
Fracturas Óseas , Granuloma de Cuerpo Extraño , Infecciones de los Tejidos Blandos , Humanos , Masculino , Femenino , Niño , Magnesio , Implantes Absorbibles , Granuloma de Cuerpo Extraño/etiología , Infecciones de los Tejidos Blandos/etiología , Fracturas Óseas/etiología , Aleaciones , Fijación Interna de Fracturas/métodos , Tornillos Óseos/efectos adversos
12.
Periodontol 2000 ; 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38305506

RESUMEN

Peri-implantitis is a plaque-associated pathological condition occurring in tissues around dental implants. It is characterized by inflammation in the peri-implant mucosa and progressive loss of supporting bone. Over the last 30 years, peri-implantitis has become a major disease burden in dentistry. An understanding of the diagnosis, etiology and pathogenesis, epidemiology, and treatment of peri-implantitis must be a central component in undergraduate and postgraduate training programs in dentistry. In view of the strong role of European research in periodontology and implant dentistry, the focus of this review was to address peri-implantitis from a European perspective. One component of the work was to summarize new and reliable data on patients with dental implants to underpin the relevance of peri-implantitis from a population perspective. The nature of the peri-implantitis lesion was evaluated through results presented in preclinical models and evaluations of human biopsy material together with an appraisal of the microbiological characteristics. An overview of strategies and outcomes presented in clinical studies on nonsurgical and surgical treatment of peri-implantitis is discussed with a particular focus on end points of therapy and recommendations presented in the S3 level Clinical Practice Guideline for the prevention and treatment of peri-implant diseases.

13.
Dev Sci ; 27(4): e13481, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38327110

RESUMEN

Recent evidence suggests that deaf children with CIs exposed to nonnative sign language from hearing parents can attain age-appropriate vocabularies in both sign and spoken language. It remains to be explored whether deaf children with CIs who are exposed to early nonnative sign language, but only up to implantation, also benefit from this input and whether these benefits also extend to memory abilities, which are strongly linked to language development. The present study examined the impact of deaf children's early short-term exposure to nonnative sign input on their spoken language and their phonological memory abilities. Deaf children who had been exposed to nonnative sign input before and after cochlear implantation were compared to deaf children who never had any exposure to sign input as well as to children with typical hearing. The children were between 5;1 and 7;1 years of age at the time of testing and were matched on age, sex, and socioeconomic status. The results suggest that even short-term exposure to nonnative sign input has positive effects on general language and phonological memory abilities as well as on nonverbal working memory-with total length of exposure to sign input being the best predictor of deaf children's performance on these measures. The present data suggest that even access to early short-term nonnative visual language input is beneficial for the language and phonological memory abilities of deaf children with cochlear implants, suggesting also that parents should not be discouraged from learning and exposing their child to sign language. RESEARCH HIGHLIGHTS: This is the first study to examine the effects of early short-term exposure to nonnative sign input on French-speaking children with cochlear implants' spoken language and memory abilities. Early short-term nonnative exposure to sign input can have positive consequences for the language and phonological memory abilities of deaf children with CIs. Extended exposure to sign input has some additional and important benefits, allowing children to perform on par with children with typical hearing.


Asunto(s)
Implantación Coclear , Cognición , Sordera , Desarrollo del Lenguaje , Lengua de Signos , Humanos , Niño , Femenino , Masculino , Preescolar , Cognición/fisiología , Implantes Cocleares , Memoria a Corto Plazo/fisiología
14.
J Periodontal Res ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38699841

RESUMEN

OBJECTIVE AND BACKGROUND: This research aimed to examine the role of C-X-C motif chemokine ligand 5 (CXCL5) and C-X-C motif chemokine ligand 8 (CXCL8; also known as IL-8) in neutrophilic inflammation triggered by peri-implantitis and to shed light on the underlying mechanisms that link them to the development of this condition. MATERIALS: This study included 40 patients who visited the Department of Periodontology at Kyungpook University Dental Hospital. They were divided into two groups based on their condition: healthy implant (HI) group (n = 20) and peri-implantitis (PI) group (n = 20). Biopsy samples of PI tissue were collected from the patients under local anesthesia. HI tissue was obtained using the same method during the second implant surgery. To construct libraries for control and test RNAs, the QuantSeq 3' mRNA-Seq Library Prep Kit (Lexogen, Inc., Austria) was used according to the manufacturer's instructions. Samples were pooled based on representative cytokines obtained from RNA sequencing results and subjected to Reverse transcription-quantitative polymerase chain reaction (RT-qPCR). Hematoxylin and eosin staining, and immunohistochemistry (IHC) analysis were performed to visually assess expression levels and analyze tissue histology. Student's t-test was employed to conduct statistical analyses. RESULTS: Initially, heatmaps were used to examine gene expression variations between the HI and PI groups based on the results of RNA sequencing. Notably, among various cytokines, CXCL5 and CXCL8 had the highest expression levels in the PI group compared with the HI group, and they are known to be associated with inflammatory responses. In the gingival tissues, the expression of genes encoding cytokines such as interleukin (IL)-1ß, tumor necrosis factor-alpha (TNF)-α, interleukin (IL)-6, and CXCL5/CXCL8 was assessed via RT-qPCR. The mRNA expression level of CXCL5/CXCL8 significantly increased in the PI group compared with the HI group (p < .045). Contrarily, the mRNA expression level of interleukin 36 receptor antagonist (IL36RN) significantly decreased (p < .008). IHC enabled examination of the distribution and intensity of CXCL5/CXCL8 protein expression within the tissue samples. Specifically, increased levels of CXCL5/CXCL8 promote inflammatory responses, cellular proliferation, migration, and invasion within the peri-implant tissues. These effects are mediated through the activation of the PI3K/Akt/NF-κB signaling pathway. CONCLUSIONS: This study found that the PI sites had higher gene expression level of CXCL8/CXCL5 in the soft tissue than HI sites, which could help achieve more accurate diagnosis and treatment planning.

15.
J Periodontal Res ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594821

RESUMEN

This image article presents a single patient receiving a reconstructed fibular bony peak (BP) for guided bone regeneration (GBR) with a customized titanium mesh. The patient was informed and understood the objectives and signed a written informed consent document before surgery.

16.
J Periodontal Res ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747072

RESUMEN

Dental implant surfaces and their unique properties can interact with the surrounding oral tissues through epigenetic cues. The present scoping review provides current perspectives on surface modifications of dental implants, their impact on the osseointegration process, and the interaction between implant surface properties and epigenetics, also in peri-implant diseases. Findings of this review demonstrate the impact of innovative surface treatments on the epigenetic mechanisms of cells, showing promising results in the early stages of osseointegration. Dental implant surfaces with properties of hydrophilicity, nanotexturization, multifunctional coatings, and incorporated drug-release systems have demonstrated favorable outcomes for early bone adhesion, increased antibacterial features, and improved osseointegration. The interaction between modified surface morphologies, different chemical surface energies, and/or release of molecules within the oral tissues has been shown to influence epigenetic mechanisms of the surrounding tissues caused by a physical-chemical interaction. Epigenetic changes around dental implants in the state of health and disease are different. In conclusion, emerging approaches in surface modifications for dental implants functionalized with epigenetics have great potential with a significant impact on modulating bone healing during osseointegration.

17.
Audiol Neurootol ; : 1-13, 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38679013

RESUMEN

INTRODUCTION: Cochlear implant (CI) users differ greatly in their rehabilitation outcomes, including speech understanding in noise. This variability may be related to brain changes associated with intact senses recruiting cortical areas from stimulation-deprived senses. Numerous studies have demonstrated such cross-modal reorganization in individuals with untreated hearing loss. How it is affected by regular use of hearing devices remains unclear, however. To shed light on this, the current study measured cortical responses reflecting comprehension abilities in experienced CI users and normal-hearing controls. METHODS: Using multichannel electroencephalography, we tested CI users who had used their devices for at least 12 months and closely matched controls (N = 2 × 13). Cortical responses reflecting comprehension abilities - the N400 and late positive complex (LPC) components - were evoked using congruent and incongruent digit-triplet stimuli. The participants' task was to assess digit-triplet congruency by means of timed button presses. All measurements were performed in speech-shaped noise 15 dB above individually measured speech recognition thresholds. Three stimulus presentation modes were used: auditory-only, visual-only, and visual-then-auditory. RESULTS: The analyses revealed no group differences in the N400 and LPC responses. In terms of response times, the CI users were slower and differentially affected by the three stimulus presentation modes relative to the controls. CONCLUSION: Compared to normal-hearing controls, experienced CI users may need more time to comprehend speech in noise. Response times can serve as a proxy for speech comprehension by CI users.

18.
Audiol Neurootol ; : 1-9, 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38447538

RESUMEN

INTRODUCTION: Cochlear implantation is the standard treatment for severe to profound hearing loss. While cochlear implant (CI) users can communicate effectively in quiet environments, speech understanding in noise remains challenging. Bimodal hearing, combining a CI in one ear and a hearing aid (HA) in the other, has shown advantages over unilateral electrical hearing, especially for speech understanding in noisy conditions. Beamforming is a technique used to improve speech understanding in noise by detecting sound direction and enhancing frontal (speech) sounds while attenuating background noise. One specific beamformer, Stereozoom, combines signals from microphones in both ears to create a focused beam toward the front resulting in a binaural beamformer (BB), in order to improve speech intelligibility in noise for bilateral and bimodal CI users. METHODS: A prospective crossover study involving 17 bimodal CI users was conducted, and participants were tested with various device configurations (CI, HA, CI + HA) with and without BB. Speech recognition testing with the Dutch/Flemish matrix test was performed in a sound-attenuated booth with diffuse noise to simulate realistic listening conditions. RESULTS: The results showed a statistically significant benefit of bimodal hearing over the CI configuration and showed a statistical significant benefit of BB for the CI and CI + HA configuration. The benefit of BB in the HA configuration was not statistically significant probably due to the higher variance. The benefit of BB in the three configurations did not differ statistically significant. CONCLUSION: In conclusion, bimodal hearing offers advantages for speech understanding in noise for CI users. BB provides a benefit in various device configurations, leading to improved speech intelligibility when speech comes from the front in challenging listening environments.

19.
Audiol Neurootol ; 29(2): 136-145, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37984348

RESUMEN

INTRODUCTION: The prevalence of hearing loss in Canada is high, with many patients requiring implantable hearing devices (IHDs) as treatment for their disease severity. Despite this need, many eligible patients do not pursue these interventions. The objective of this study was to examine rates of IHD based on geographic location to understand locoregional variation in access to care. STUDY DESIGN: This was a retrospective population-based cohort study. SETTING: All hospitals in the Canadian province of Ontario. METHODS: Of all patients with IHD between April 1, 1992, and March 31, 2021, cochlear implants (CIs) (4,720) and bone-anchored hearing aids (BAHA) (1,125) cohorts were constructed. Place of residence was categorized based on Local Health Integrated Network (LHIN). Summary statistics for place of surgical institution based on LHIN at first surgery, name of institution of first surgery and "as the crow flies" distance (in km) between place of residence and surgical institution were calculated. Rate of implantations was calculated for LHIN regions based on number of surgeries per 1,000,000 persons/years. RESULTS: Toronto Central, Central, Central East, and Champlain regions had >10% of patients undergoing BAHA and CI. 1,019 (90.6%) and 4,232 (89.7%) of patients receiving BAHA and CI, respectively, resided in urban/suburban regions and 94 patients (8.4%) and 436 (9.2%) resided in rural regions. The median distance between residential location and the institution was 46.4 km (interquartile range [IQR], 18.9-103.6) and 44.7 km (IQR, 15.7-96.9) for BAHA and CI, respectively. From 1992 to 2021, the number of CI and BAHA performed across Ontario increased by 17 folds and 6 folds, respectively. CONCLUSION: This large comprehensive population study provides longitudinal insight into the access to care of IHD based on geographic factors. Our findings of the present population-based study indicate an overall increase in access to devices with disproportionate access to care based on geographic locations. Further work is needed to characterize barriers to IHD access to align with demands.


Asunto(s)
Implantes Cocleares , Audífonos , Humanos , Estudios Retrospectivos , Ontario/epidemiología , Estudios de Cohortes , Audición , Accesibilidad a los Servicios de Salud , Conducción Ósea
20.
J Clin Periodontol ; 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38837305

RESUMEN

AIM: The aim of this retrospective long-term follow-up of a 3-month RCT was to assess whether non-surgical peri-implantitis treatment with adjunctive systemic antibiotics influenced the need for additional surgical treatment. MATERIALS AND METHODS: Patients enrolled in an aftercare programme following non-surgical peri-implantitis treatment, with or without systemic amoxicillin and metronidazole, were analysed. Data had previously been collected pre-treatment (T0) and 3 months after treatment (T1) and were additionally collected during subsequent aftercare visits, until the final assessment (T2). Primary outcome was the need for additional surgical peri-implantitis therapy during the aftercare programme, analysed via Kaplan-Meier analysis and Cox regression. Secondary outcomes involved clinical parameters, assessed using parametric and non-parametric tests. RESULTS: Forty-five patients (22 AB- group, 23 AB+ group) were included. The mean follow-up time between T1 and T2 was 35.9 months (SD = 21.0). 73.9% of the AB+ group and 50.0% of the AB- group did not receive additional surgical therapy (log-rank test, p = .110). The adjusted Cox regression model did not provide a significant result for antibiotics (ß = .441, 95% CI = 0.159-1.220, p = .115). Univariable regression analysis highlighted the influence of baseline peri-implant pocket depth on the need for surgical treatment (ß = 1.446, 95% CI = 1.035-2.020, p = .031). CONCLUSIONS: Systemic amoxicillin and metronidazole administered during non-surgical peri-implantitis treatment do not seem to prevent the need for additional surgical therapy in the long term, during a structured aftercare programme.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA