Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.337
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 120(1): e2210214120, 2023 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-36580596

RESUMEN

Respiratory X-ray imaging enhanced by phase contrast has shown improved airway visualization in animal models. Limitations in current X-ray technology have nevertheless hindered clinical translation, leaving the potential clinical impact an open question. Here, we explore phase-contrast chest radiography in a realistic in silico framework. Specifically, we use preprocessed virtual patients to generate in silico chest radiographs by Fresnel-diffraction simulations of X-ray wave propagation. Following a reader study conducted with clinical radiologists, we predict that phase-contrast edge enhancement will have a negligible impact on improving solitary pulmonary nodule detection (6 to 20 mm). However, edge enhancement of bronchial walls visualizes small airways (< 2 mm), which are invisible in conventional radiography. Our results show that phase-contrast chest radiography could play a future role in observing small-airway obstruction (e.g., relevant for asthma or early-stage chronic obstructive pulmonary disease), which cannot be directly visualized using current clinical methods, thereby motivating the experimental development needed for clinical translation. Finally, we discuss quantitative requirements on distances and X-ray source/detector specifications for clinical implementation of phase-contrast chest radiography.


Asunto(s)
Nódulo Pulmonar Solitario , Tomografía Computarizada por Rayos X , Animales , Tomografía Computarizada por Rayos X/métodos , Radiografía Torácica , Radiografía , Nódulo Pulmonar Solitario/diagnóstico por imagen
2.
J Neurosci ; 44(3)2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-37968115

RESUMEN

Quantifying the effects of free breathing on cerebral venous flow is crucial for understanding cerebral circulation mechanisms and clinical applications. Unlike conventional cine phase-contrast MRI sequences (CINE-PC), real-time phase-contrast MRI sequences (RT-PC) can provide a continuous beat-to-beat flow signal that makes it possible to quantify the effect of breathing on cerebral venous flow. In this study, we examined 28 healthy human participants, comprising of 14 males and 14 females. Blood flows in the right/left internal jugular veins in the extracranial plane and the superior sagittal sinus (SSS) and straight sinus in the intercranial plane were quantified using CINE-PC and RT-PC. The first objective of this study was to determine the accuracy of RT-PC in quantifying cerebral venous flow, relative to CINE-PC. The second, and main objective, was to quantify the effect of free breathing on cerebral venous flow, using a time-domain multiparameter analysis method. Our results showed that RT-PC can accurately quantify cerebral venous flow with a 2 × 2 mm2 spatial resolution and 75 ms/image time resolution. The mean flow rate, amplitude, stroke volume, and cardiac period of cerebral veins were significantly higher from the mid-end phase of expiration to the mid-end phase of inspiration. Breathing affected the mean flow rates in the jugular veins more than those in the SSS and straight sinus. Furthermore, the effects of free breathing on the flow rate of the left and right jugular veins were not synchronous. These new findings provide a useful reference for better understanding the mechanisms of cerebral circulation.


Asunto(s)
Venas Cerebrales , Masculino , Adulto , Femenino , Humanos , Venas Cerebrales/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Imagen por Resonancia Magnética/métodos , Circulación Cerebrovascular , Venas Yugulares/diagnóstico por imagen
3.
J Pathol ; 263(2): 178-189, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38551075

RESUMEN

The effects of the obliteration of portal venules (OPV) in cirrhotic portal hypertension are poorly understood. To investigate its contribution to portal hypertension in biliary cirrhosis and its underlying mechanism, we evaluated OPV using two-dimensional (2D) histopathology in liver explants from patients with biliary atresia (BA, n = 63), primary biliary cholangitis (PBC, n = 18), and hepatitis B-related cirrhosis (Hep-B-cirrhosis, n = 35). Then, three-dimensional (3D) OPV was measured by X-ray phase-contrast CT in two parallel models in rats following bile duct ligation (BDL) or carbon tetrachloride (CCl4) administration, representing biliary cirrhosis and post-necrotic cirrhosis, respectively. The portal pressure was also measured in the two models. Finally, the effects of proliferative bile ducts on OPV were investigated. We found that OPV was significantly more frequent in patients with biliary cirrhosis, including BA (78.57 ± 16.45%) and PBC (60.00 ± 17.15%), than that in Hep-B-cirrhotic patients (29.43 ± 14.94%, p < 0.001). OPV occurred earlier, evidenced by the paired liver biopsy at a Kasai procedure (KP), and was irreversible even after a successful KP in the patients with BA. OPV was also significantly more frequent in the BDL models than in the CCl4 models, as shown by 2D and 3D quantitative analysis. Portal pressure was significantly higher in the BDL model than that in the CCl4 model. With the proliferation of bile ducts, portal venules were compressed and irreversibly occluded, contributing to the earlier and higher portal pressure in biliary cirrhosis. OPV, as a pre-sinusoidal component, plays a key role in the pathogenesis of portal hypertension in biliary cirrhosis. The proliferated bile ducts and ductules gradually take up the 'territory' originally attributed to portal venules and compress the portal venules, which may lead to OPV in biliary cirrhosis. © 2024 The Pathological Society of Great Britain and Ireland.


Asunto(s)
Hipertensión Portal , Cirrosis Hepática Biliar , Vena Porta , Hipertensión Portal/patología , Hipertensión Portal/fisiopatología , Animales , Cirrosis Hepática Biliar/patología , Cirrosis Hepática Biliar/complicaciones , Cirrosis Hepática Biliar/fisiopatología , Masculino , Humanos , Femenino , Vena Porta/patología , Vénulas/patología , Ratas , Adulto , Presión Portal , Persona de Mediana Edad , Modelos Animales de Enfermedad , Hígado/patología , Hígado/irrigación sanguínea , Ratas Sprague-Dawley , Conductos Biliares/patología , Adulto Joven , Adolescente
4.
Cell Struct Funct ; 49(1): 21-29, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38797697

RESUMEN

Cell biologists have long sought the ability to observe intracellular structures in living cells without labels. This study presents procedures to adjust a commercially available apodized phase-contrast (APC) microscopy system for better visualizing the dynamic behaviors of various subcellular organelles in living cells. By harnessing the versatility of this technique to capture sequential images, we could observe morphological changes in cellular geometry after virus infection in real time without probes or invasive staining. The tune-up APC microscopy system is a highly efficient platform for simultaneously observing the dynamic behaviors of diverse subcellular structures with exceptional resolution.


Asunto(s)
Microscopía de Contraste de Fase , Microscopía de Contraste de Fase/métodos , Humanos , Animales , Orgánulos/ultraestructura , Células HeLa
5.
Small ; : e2311635, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703033

RESUMEN

Most properties of solid materials are defined by their internal electric field and charge density distributions which so far are difficult to measure with high spatial resolution. Especially for 2D materials, the atomic electric fields influence the optoelectronic properties. In this study, the atomic-scale electric field and charge density distribution of WSe2 bi- and trilayers are revealed using an emerging microscopy technique, differential phase contrast (DPC) imaging in scanning transmission electron microscopy (STEM). For pristine material, a higher positive charge density located at the selenium atomic columns compared to the tungsten atomic columns is obtained and tentatively explained by a coherent scattering effect. Furthermore, the change in the electric field distribution induced by a missing selenium atomic column is investigated. A characteristic electric field distribution in the vicinity of the defect with locally reduced magnitudes compared to the pristine lattice is observed. This effect is accompanied by a considerable inward relaxation of the surrounding lattice, which according to first principles DFT calculation is fully compatible with a missing column of Se atoms. This shows that DPC imaging, as an electric field sensitive technique, provides additional and remarkable information to the otherwise only structural analysis obtained with conventional STEM imaging.

6.
J Synchrotron Radiat ; 31(Pt 1): 186-194, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37971957

RESUMEN

Here, high-throughput tomography (HiTT), a fast and versatile phase-contrast imaging platform for life-science samples on the EMBL beamline P14 at DESY in Hamburg, Germany, is presented. A high-photon-flux undulator beamline is used to perform tomographic phase-contrast acquisition in about two minutes which is linked to an automated data processing pipeline that delivers a 3D reconstructed data set less than a minute and a half after the completion of the X-ray scan. Combining this workflow with a sophisticated robotic sample changer enables the streamlined collection and reconstruction of X-ray imaging data from potentially hundreds of samples during a beam-time shift. HiTT permits optimal data collection for many different samples and makes possible the imaging of large sample cohorts thus allowing population studies to be attempted. The successful application of HiTT on various soft tissue samples in both liquid (hydrated and also dehydrated) and paraffin-embedded preparations is demonstrated. Furthermore, the feasibility of HiTT to be used as a targeting tool for volume electron microscopy, as well as using HiTT to study plant morphology, is demonstrated. It is also shown how the high-throughput nature of the work has allowed large numbers of `identical' samples to be imaged to enable statistically relevant sample volumes to be studied.


Asunto(s)
Robótica , Sincrotrones , Rayos X , Tomografía Computarizada por Rayos X , Alemania
7.
J Synchrotron Radiat ; 31(Pt 4): 896-909, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38843003

RESUMEN

Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates `unreasonable' effectiveness of the method. On the other hand, when the process of free-space propagation is performed in software, using the detected intensity distribution in the object plane, it cannot reproduce the same effectiveness, due to the amplification of photon shot noise. Here, it is shown that the performance of Paganin's method is determined by just two dimensionless parameters: the Fresnel number and the ratio of the real decrement to the imaginary part of the refractive index of the imaged object. The relevant theoretical analysis is performed first, followed by computer simulations and then by a brief test using experimental images collected at a synchrotron beamline. More extensive experimental tests will be presented in the second part of this paper.

8.
J Synchrotron Radiat ; 31(Pt 4): 923-935, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38861370

RESUMEN

X-rays can penetrate deeply into biological cells and thus allow for examination of their internal structures with high spatial resolution. In this study, X-ray phase-contrast imaging and tomography is combined with an X-ray-compatible optical stretcher and microfluidic sample delivery. Using this setup, individual cells can be kept in suspension while they are examined with the X-ray beam at a synchrotron. From the recorded holograms, 2D phase shift images that are proportional to the projected local electron density of the investigated cell can be calculated. From the tomographic reconstruction of multiple such projections the 3D electron density can be obtained. The cells can thus be studied in a hydrated or even living state, thus avoiding artifacts from freezing, drying or embedding, and can in principle also be subjected to different sample environments or mechanical strains. This combination of techniques is applied to living as well as fixed and stained NIH3T3 mouse fibroblasts and the effect of the beam energy on the phase shifts is investigated. Furthermore, a 3D algebraic reconstruction scheme and a dedicated mathematical description is used to follow the motion of the trapped cells in the optical stretcher for multiple rotations.

9.
J Synchrotron Radiat ; 31(Pt 1): 136-149, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38095668

RESUMEN

Bone material contains a hierarchical network of micro- and nano-cavities and channels, known as the lacuna-canalicular network (LCN), that is thought to play an important role in mechanobiology and turnover. The LCN comprises micrometer-sized lacunae, voids that house osteocytes, and submicrometer-sized canaliculi that connect bone cells. Characterization of this network in three dimensions is crucial for many bone studies. To quantify X-ray Zernike phase-contrast nanotomography data, deep learning is used to isolate and assess porosity in artifact-laden tomographies of zebrafish bones. A technical solution is proposed to overcome the halo and shade-off domains in order to reliably obtain the distribution and morphology of the LCN in the tomographic data. Convolutional neural network (CNN) models are utilized with increasing numbers of images, repeatedly validated by `error loss' and `accuracy' metrics. U-Net and Sensor3D CNN models were trained on data obtained from two different synchrotron Zernike phase-contrast transmission X-ray microscopes, the ANATOMIX beamline at SOLEIL (Paris, France) and the P05 beamline at PETRA III (Hamburg, Germany). The Sensor3D CNN model with a smaller batch size of 32 and a training data size of 70 images showed the best performance (accuracy 0.983 and error loss 0.032). The analysis procedures, validated by comparison with human-identified ground-truth images, correctly identified the voids within the bone matrix. This proposed approach may have further application to classify structures in volumetric images that contain non-linear artifacts that degrade image quality and hinder feature identification.


Asunto(s)
Aprendizaje Profundo , Animales , Humanos , Artefactos , Porosidad , Pez Cebra , Huesos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos
10.
Magn Reson Med ; 91(3): 911-925, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37927206

RESUMEN

PURPOSE: Diastolic function evaluation requires estimates of early and late diastolic mitral filling velocities (E and A) and of mitral annulus tissue velocity (e'). We aimed to develop an MRI method for simultaneous all-in-one diastolic function evaluation in a single scan by generating a 2D phase-contrast (PC) sequence with balanced steady-state free precession (bSSFP) contrast (PC-SSFP). E and A could then be measured with PC, and e' estimated by valve tracking on the magnitude images, using an established deep learning framework. METHODS: Our PC-SSFP used in-plane flow-encoding, with zeroth and first moment nulling over each TR. For further acceleration, different k-t principal component analysis (PCA) methods were investigated with both retrospective and prospective undersampling. PC-SSFP was compared to separate balanced SSFP cine and PC-gradient echo acquisitions in phantoms and in 10 healthy subjects. RESULTS: Phantom experiments showed that PC-SSFP measured accurate velocities compared to PC-gradient echo (r = 0.98 for a range of pixel-wise velocities -80 cm/s to 80 cm/s). In subjects, PC-SSFP generated high SNR and myocardium-blood contrast, and excellent agreement for E (limits of agreement [LOA] 0.8 ± 2.4 cm/s, r = 0.98), A (LOA 2.5 ± 4.1 cm/s, r = 0.97), and e' (LOA 0.3 ± 2.6 cm/s, r = 1.00), versus the standard methods. The best k-t PCA approach processed the complex difference data and substituted in raw k-space data. With prospective k-t PCA acceleration, higher frame rates were achieved (50 vs. 25 frames per second without k-t PCA), yielding a 13% higher e'. CONCLUSION: The proposed PC-SSFP method achieved all-in-one diastolic function evaluation.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Análisis de Componente Principal , Estudios Retrospectivos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Diástole
11.
Magn Reson Med ; 92(2): 751-760, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38469944

RESUMEN

PURPOSE: To develop an inline automatic quality control to achieve consistent diagnostic image quality with subject-specific scan time, and to demonstrate this method for 2D phase-contrast flow MRI to reach a predetermined SNR. METHODS: We designed a closed-loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free-breathing 2D pseudo-golden-angle spiral phase-contrast sequence was modified to listen for image-quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR-driven "stop" was assessed inline. RESULTS: SNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR-driven acquisition time was 2 min 39 s ± 67 s (aorta) and 3 min ± 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery). CONCLUSION: The inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Control de Calidad , Relación Señal-Ruido , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Adulto , Imagen por Resonancia Magnética/métodos , Masculino , Voluntarios Sanos , Algoritmos , Femenino , Arteria Pulmonar/diagnóstico por imagen , Aorta/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Estudios Retrospectivos , Respiración , Reproducibilidad de los Resultados
12.
Magn Reson Med ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38817154

RESUMEN

PURPOSE: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve-tracking 2D method for measuring flow through the dynamic tricuspid valve. METHODS: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long-axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D-PC scans acquired in a static slice localized at the end-systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels. RESULTS: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve-tracking PC net diastolic flow showed excellent correlation with SV by right-ventricle planimetry (bias ± 1.96 SD = -0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (-1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right-ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin-systole. In one patient, valve-tracking PC displayed a high-velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography. CONCLUSION: Automated valve-tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.

13.
Magn Reson Med ; 91(5): 1965-1977, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38084397

RESUMEN

PURPOSE: To develop a highly-accelerated, real-time phase contrast (rtPC) MRI pulse sequence with 40 fps frame rate (25 ms effective temporal resolution). METHODS: Highly-accelerated golden-angle radial sparse parallel (GRASP) with over regularization may result in temporal blurring, which in turn causes underestimation of peak velocity. Thus, we amplified GRASP performance by synergistically combining view-sharing (VS) and k-space weighted image contrast (KWIC) filtering. In 17 pediatric patients with congenital heart disease (CHD), the conventional GRASP and the proposed GRASP amplified by VS and KWIC (or GRASP + VS + KWIC) reconstruction for rtPC MRI were compared with respect to clinical standard PC MRI in measuring hemodynamic parameters (peak velocity, forward volume, backward volume, regurgitant fraction) at four locations (aortic valve, pulmonary valve, left and right pulmonary arteries). RESULTS: The proposed reconstruction method (GRASP + VS + KWIC) achieved better effective spatial resolution (i.e., image sharpness) compared with conventional GRASP, ultimately reducing the underestimation of peak velocity from 17.4% to 6.4%. The hemodynamic metrics (peak velocity, volumes) were not significantly (p > 0.99) different between GRASP + VS + KWIC and clinical PC, whereas peak velocity was significantly (p < 0.007) lower for conventional GRASP. RtPC with GRASP + VS + KWIC also showed the ability to assess beat-to-beat variation and detect the highest peak among peaks. CONCLUSION: The synergistic combination of GRASP, VS, and KWIC achieves 25 ms effective temporal resolution (40 fps frame rate), while minimizing the underestimation of peak velocity compared with conventional GRASP.


Asunto(s)
Medios de Contraste , Cardiopatías Congénitas , Humanos , Niño , Imagen por Resonancia Magnética/métodos , Pulmón , Arteria Pulmonar , Cardiopatías Congénitas/diagnóstico por imagen
14.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38440807

RESUMEN

PURPOSE: Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T. METHODS: Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated. RESULTS: Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups. CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.


Asunto(s)
Arterias Cerebrales , Imagen por Resonancia Magnética , Flujo Pulsátil , Humanos , Femenino , Masculino , Adulto , Anciano , Reproducibilidad de los Resultados , Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/fisiología , Flujo Pulsátil/fisiología , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Adulto Joven , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Angiografía por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos
15.
J Anat ; 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613211

RESUMEN

Auditory sensitivity and frequency resolution depend on the optimal transfer of sound-induced vibrations from the basilar membrane (BM) to the inner hair cells (IHCs), the principal auditory receptors. There remains a paucity of information on how this is accomplished along the frequency range in the human cochlea. Most of the current knowledge is derived either from animal experiments or human tissue processed after death, offering limited structural preservation and optical resolution. In our study, we analyzed the cytoarchitecture of the human cochlear partition at different frequency locations using high-resolution microscopy of uniquely preserved normal human tissue. The results may have clinical implications and increase our understanding of how frequency-dependent acoustic vibrations are carried to human IHCs. A 1-micron-thick plastic-embedded section (mid-modiolar) from a normal human cochlea uniquely preserved at lateral skull base surgery was analyzed using light and transmission electron microscopy (LM, TEM). Frequency locations were estimated using synchrotron radiation phase-contrast imaging (SR-PCI). Archival human tissue prepared for scanning electron microscopy (SEM) and super-resolution structured illumination microscopy (SR-SIM) were also used and compared in this study. Microscopy demonstrated great variations in the dimension and architecture of the human cochlear partition along the frequency range. Pillar cell geometry was closely regulated and depended on the reticular lamina slope and tympanic lip angle. A type II collagen-expressing lamina extended medially from the tympanic lip under the inner sulcus, here named "accessory basilar membrane." It was linked to the tympanic lip and inner pillar foot, and it may contribute to the overall compliance of the cochlear partition. Based on the findings, we speculate on the remarkable microanatomic inflections and geometric relationships which relay different sound-induced vibrations to the IHCs, including their relevance for the evolution of human speech reception and electric stimulation with auditory implants. The inner pillar transcellular microtubule/actin system's role of directly converting vibration energy to the IHC cuticular plate and ciliary bundle is highlighted.

16.
J Anat ; 244(1): 159-169, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37602519

RESUMEN

The symmetry of the right and left bronchi, proposed in a previous comparative anatomical study as the basic model of the mammalian bronchial tree, was examined to determine if it applied to the embryonic human bronchial tree. Imaging data of 41 human embryo specimens at Carnegie stages (CS) 16-23 (equivalent to 6-8 weeks after fertilization) belonging to the Kyoto collection were obtained using phase-contrast X-ray computed tomography. Three-dimensional bronchial trees were then reconstructed from these images. Bronchi branching from both main bronchi were labeled as dorsal, ventral, medial, or lateral systems based on the branching position with numbering starting cranially. The length from the tracheal bifurcation to the branching point of the labeled bronchus was measured, and the right-to-left ratio of the same labeled bronchus in both lungs was calculated. In both lungs, the human embryonic bronchial tree showed symmetry with an alternating pattern of dorsal and lateral systems up to segmental bronchus B9 as the basic shape, with a more peripheral variation. This pattern is similar to that described in adult human lungs. Bronchial length increased with the CS in all labeled bronchi, whereas the right-to-left ratio was constant at approximately 1.0. The data demonstrated that the prototype of the human adult bronchial branching structure is formed and maintained in the embryonic stage. The morphology and branching position of all lobar bronchi and B6, B8, B9, and the subsegmental bronchus of B10 may be genetically determined. On the other hand, no common structures between individual embryos were found in the peripheral branches after the subsegmental bronchus of B10, suggesting that branch formation in this region is influenced more by environmental factors than by genetic factors.


Asunto(s)
Bronquios , Pulmón , Adulto , Animales , Humanos , Bronquios/anatomía & histología , Bronquios/diagnóstico por imagen , Bronquios/embriología , Pulmón/anatomía & histología , Pulmón/diagnóstico por imagen , Pulmón/embriología , Tomografía Computarizada por Rayos X/métodos , Tráquea/anatomía & histología , Tráquea/diagnóstico por imagen , Tráquea/embriología
17.
J Anat ; 244(1): 142-158, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37559438

RESUMEN

The left atrium wall has several origins, including the body, appendage, septum, atrial-ventricular canal, posterior wall, and venous component. Here, we describe the morphogenesis of left atrium based on high-resolution imaging (phase-contrast X-ray computed tomography and magnetic resonance imaging). Twenty-three human embryos and 19 fetuses were selected for this study. Three-dimensional cardiac images were reconstructed, and the pulmonary veins and left atrium, including the left atrial appendage, were evaluated morphologically and quantitatively. The positions of the pericardial reflections were used as landmarks for the border of the pericardial cavity. The common pulmonary vein was observed in three specimens at Carnegie stages 17-18. The pericardium was detected at the four pulmonary veins (left superior, left inferior, right superior, and right inferior pulmonary veins) at one specimen at Carnegie stage 18 and all larger specimens, except the four samples. Our results suggest that the position of the pericardial reflections was determined at two pulmonary veins (right and left pulmonary vein) and four pulmonary veins almost simultaneously when the dorsal mesocardial connection between the embryo and heart regressed. The magnetic resonance images and reconstructed heart cavity images confirmed that the left atrium folds were present at the junction between the body and venous component. Three-dimensional reconstruction showed that the four pulmonary veins entered the dorsal left atrium tangentially from the lateral to the medial direction. More specifically, the right pulmonary veins entered at a greater angle than the left pulmonary veins. The distance between the superior and inferior pulmonary veins was shorter than that between the left and right pulmonary veins. Three-dimensional reconstruction showed that the venous component increased proportionally with growth. No noticeable differences in discrimination between the right and left parts of the venous component emerged, while the junction between the venous component and body gradually became inconspicuous but was still recognizable by the end of the observed early fetal period. The left superior pulmonary vein had the smallest cross-sectional area and most flattened shape, whereas the other three were similar in area and shape. The left atrial appendage had a large volume in the center and extended to the periphery as a lobe-like structure. The left atrial appendage orifice increased in the area and tended to become flatter with growth. The whole left atrium volume^(1/3) increased almost proportionally with growth, parallel to the whole heart volume. This study provided a three-dimensional and quantitative description of the developmental process of the left atrium, comprising the venous component and left atrial appendage formation, from the late embryonic to the early fetal stages.


Asunto(s)
Apéndice Atrial , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/anatomía & histología , Apéndice Atrial/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Feto , Morfogénesis
18.
NMR Biomed ; 37(8): e5132, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38465514

RESUMEN

The glymphatic system is a system of specialized perivascular spaces in the brain that facilitates removal of toxic waste solutes from the brain. Evaluation of glymphatic system function by means of magnetic resonance imaging (MRI) has thus far been largely focused on rodents because of the limitations of intrathecal delivery of gadolinium-based contrast agents to humans. This review discusses MRI methods that can be employed clinically for glymphatic-related measurements intended for early diagnosis, prevention, and the treatment of various neurological conditions. Although glymphatic system-based MRI research is in its early stages, recent studies have identified promising noninvasive MRI markers associated with glymphatic system alterations in neurological diseases. However, further optimization in data acquisition, validation, and modeling are needed to investigate the glymphatic system within the clinical setting.


Asunto(s)
Sistema Glinfático , Imagen por Resonancia Magnética , Sistema Glinfático/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Animales , Encéfalo/diagnóstico por imagen
19.
NMR Biomed ; 37(7): e5082, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38124351

RESUMEN

Neurological disorders can manifest with altered neurofluid dynamics in different compartments of the central nervous system. These include alterations in cerebral blood flow, cerebrospinal fluid (CSF) flow, and tissue biomechanics. Noninvasive quantitative assessment of neurofluid flow and tissue motion is feasible with phase contrast magnetic resonance imaging (PC MRI). While two-dimensional (2D) PC MRI is routinely utilized in research and clinical settings to assess flow dynamics through a single imaging slice, comprehensive neurofluid dynamic assessment can be limited or impractical. Recently, four-dimensional (4D) flow MRI (or time-resolved three-dimensional PC with three-directional velocity encoding) has emerged as a powerful extension of 2D PC, allowing for large volumetric coverage of fluid velocities at high spatiotemporal resolution within clinically reasonable scan times. Yet, most 4D flow studies have focused on blood flow imaging. Characterizing CSF flow dynamics with 4D flow (i.e., 4D CSF flow) is of high interest to understand normal brain and spine physiology, but also to study neurological disorders such as dysfunctional brain metabolite waste clearance, where CSF dynamics appear to play an important role. However, 4D CSF flow imaging is challenged by the long T1 time of CSF and slower velocities compared with blood flow, which can result in longer scan times from low flip angles and extended motion-sensitive gradients, hindering clinical adoption. In this work, we review the state of 4D CSF flow MRI including challenges, novel solutions from current research and ongoing needs, examples of clinical and research applications, and discuss an outlook on the future of 4D CSF flow.


Asunto(s)
Líquido Cefalorraquídeo , Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Líquido Cefalorraquídeo/diagnóstico por imagen , Líquido Cefalorraquídeo/fisiología , Animales , Hidrodinámica , Circulación Cerebrovascular/fisiología , Reología
20.
J Magn Reson Imaging ; 59(1): 70-81, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37170640

RESUMEN

Cerebral blood flow (CBF) is an important hemodynamic parameter to evaluate brain health. It can be obtained quantitatively using medical imaging modalities such as magnetic resonance imaging and positron emission tomography (PET). Although CBF in adults has been widely studied and linked with cerebrovascular and neurodegenerative diseases, CBF data in healthy children are sparse due to the challenges in pediatric neuroimaging. An understanding of the factors affecting pediatric CBF and its normal range is crucial to determine the optimal CBF measuring techniques in pediatric neuroradiology. This review focuses on pediatric CBF studies using neuroimaging techniques in 32 articles including 2668 normal subjects ranging from birth to 18 years old. A systematic literature search was conducted in PubMed, Embase, and Scopus and reported following the preferred reporting items for systematic reviews and meta-analyses (PRISMA). We identified factors (such as age, gender, mood, sedation, and fitness) that have significant effects on pediatric CBF quantification. We also investigated factors influencing the CBF measurements in infants. Based on this review, we recommend best practices to improve CBF measurements in pediatric neuroimaging. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen , Adulto , Lactante , Humanos , Niño , Neuroimagen/métodos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Marcadores de Spin
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA