1.
J Biomech Eng ; 144(2)2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34423812

RESUMEN

The primary fixation and long-term stability of a cementless femoral implant depend on bone ingrowth within the porous coating. Although attempts were made to quantify the peri-implant bone ingrowth using the finite element (FE) analysis and mechanoregulatory principles, the tissue differentiation patterns on a porous-coated hip stem have scarcely been investigated. The objective of this study is to predict the spatial distribution of evolutionary bone ingrowth around an uncemented hip stem, using a three-dimensional (3D) multiscale mechanobiology-based numerical framework. Multiple load cases representing a variety of daily living activities, including walking, stair climbing, sitting down, and standing up from a chair, were used as applied loading conditions. The study accounted for the local variations in host bone material properties and implant-bone relative displacements of the macroscale implanted FE model, in order to predict bone ingrowth in microscale representative volume elements (RVEs) of 12 interfacial regions. In majority RVEs, 20-70% bone tissue (immature and mature) was predicted after 2 months, contributing toward a progressive increase in average Young's modulus (1200-3000 MPa) of the interbead tissue layer. Higher bone ingrowth (mostly greater than 60%) was predicted in the anterolateral regions of the implant, as compared to the posteromedial side (20-50%). New bone tissue was formed deeper inside the interbead spacing, adhering to the implant surface. The study helps to gain an insight into the degree of osseointegration of a porous-coated femoral implant.


Asunto(s)
Fémur , Prótesis de Cadera , Algoritmos , Módulo de Elasticidad , Fémur/cirugía , Análisis de Elementos Finitos , Prótesis e Implantes
2.
Int J Mol Sci ; 23(3)2022 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-35163682

RESUMEN

A lack of primary stability and osteointegration in metallic implants may result in implant loosening and failure. Adding porosity to metallic implants reduces the stress shielding effect and improves implant performance, allowing the surrounding bone tissue to grow into the scaffold. However, a bioactive surface is needed to stimulate implant osteointegration and improve mechanical stability. In this study, porous titanium implants were produced via powder sintering to create different porous diameters and open interconnectivity. Two strategies were used to generate a bioactive surface on the metallic foams: (1) an inorganic alkali thermochemical treatment, (2) grafting a cell adhesive tripeptide (RGD). RGD peptides exhibit an affinity for integrins expressed by osteoblasts, and have been reported to improve osteoblast adhesion, whereas the thermochemical treatment is known to improve titanium implant osseointegration upon implantation. Bioactivated scaffolds and control samples were implanted into the tibiae of rabbits to analyze the effect of these two strategies in vivo regarding bone tissue regeneration through interconnected porosity. Histomorphometric evaluation was performed at 4 and 12 weeks after implantation. Bone-to-implant contact (BIC) and bone in-growth and on-growth were evaluated in different regions of interest (ROIs) inside and outside the implant. The results of this study show that after a long-term postoperative period, the RGD-coated samples presented higher quantification values of quantified newly formed bone tissue in the implant's outer area. However, the total analyzed bone in-growth was observed to be slightly greater in the scaffolds treated with alkali thermochemical treatment. These results suggest that both strategies contribute to enhancing porous metallic implant stability and osteointegration, and a combination of both strategies might be worth pursuing.


Asunto(s)
Álcalis/farmacología , Materiales Biocompatibles Revestidos/farmacología , Metalurgia , Oligopéptidos/farmacología , Oseointegración , Temperatura , Andamios del Tejido/química , Titanio/farmacología , Animales , Femenino , Implantes Experimentales , Oseointegración/efectos de los fármacos , Osteogénesis/efectos de los fármacos , Porosidad , Polvos , Conejos
3.
J Foot Ankle Surg ; 60(5): 881-886, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33781640

RESUMEN

Few studies have characterized the clinical outcomes of 45S5 Bioglass® applied as a bone graft to that of allogeneic bone applied in calcaneal open curettage. Therefore, the purpose of the present investigation was to compare the outcomes of patients with calcaneal tumors and tumor-like lesions treated by open curettage with 45S5 Bioglass® or allogeneic bone. Of the 31 patients who underwent open curettage (18 cases of unicameral bone cysts, 7 cases of aneurysmal bone cysts, and 6 cases of intraosseous lipoma), 16 (52%) received grafts with 45S5 Bioglass® and 15 (48%) with allogeneic bone. All the feet achieved bone fusion according to the modified Neer radiographic classification system at the last follow-up examination. The mean bone ingrowth time for the grafts with 45S5 Bioglass® versus allogeneic bone was 3.71 ± 0.86 versus 4.46 ± 1.04 months (p = .038), the mean bone healing time was 4.86 ± 0.93 versus 5.73 ± 1.07 months (p = .021), and the mean incision drying time was 7.2 ± 1.8 versus 8.2 ± 1.5 days (p = .047), respectively. No differences were found in the postoperative American Orthopaedic Foot and Ankle Society ankle-hindfoot scale scores between the 2 groups (p = .213). These results show that 45S5 Bioglass® can better facilitate the formation of new bone with a faster drying time of the incision than allogeneic bone. Although both materials can benefit the clinical outcomes of calcaneal tumors and tumor-like lesions, further studies are needed to observe the long-term complications and lesion recurrence rates.


Asunto(s)
Calcáneo , Trasplante de Células Madre Hematopoyéticas , Calcáneo/diagnóstico por imagen , Calcáneo/cirugía , Legrado , Vidrio , Humanos , Recurrencia Local de Neoplasia
4.
J Shoulder Elbow Surg ; 29(11): 2292-2298, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32499196

RESUMEN

BACKGROUND: Glenoid component loosening remains an important concern in anatomic total shoulder arthroplasty. The aim of this study was to evaluate the clinical and radiographic results of a fully uncemented all-polyethylene fluted central peg bone-ingrowth glenoid component at a minimum 5-year follow-up. METHODS: Thirty-five shoulders in 31 patients (mean age, 73 years) with a mean follow-up of 100 months were retrospectively evaluated at an early and mid-term time point for Constant score (CS). Computed tomography visualized glenoid component fixation at both time points. RESULTS: Mean CS improved from 40 preoperatively to 66 postoperatively at latest follow-up (P < .001). A mean CS of 74 at early follow-up remained consistent with a mean CS of 66 at latest follow-up (P = .158), with only strength demonstrating a decrease over time (P < .001). An initial osseointegration rate of 81% at early follow-up decreased to 71% at latest follow-up with 74% of the shoulders demonstrating progressive radiolucent lines, resulting in a radiographic loosening rate of 31%. Of the 35 shoulders, 4 were revised (survival rate of 88%), of which 2 due to symptomatic aseptic loosening. CONCLUSIONS: Uncemented fixation of an all-polyethylene central peg bone-ingrowth glenoid was associated with satisfactory clinical and radiographic scores, and an acceptable revision rate at mid- to long-term follow-up. Despite initial bony osseointegration in the majority of cases, radiographic loosening over time remains a concern, potentially jeopardizing long-lasting fixation of this type of glenoid component when implanted in an off-label uncemented fashion.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Artroplastía de Reemplazo de Hombro/métodos , Cavidad Glenoidea/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Prótesis de Hombro , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Uso Fuera de lo Indicado , Oseointegración , Polietileno , Periodo Posoperatorio , Diseño de Prótesis , Falla de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos , Articulación del Hombro/cirugía , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
J Arthroplasty ; 35(3): 870-876, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31694778

RESUMEN

BACKGROUND: Cementless total knee arthroplasty has been developed to decrease the incidence of failure in younger and more active patients. However, failures are still more common in cementless versus cemented components. It is hypothesized that this is triggered by incomplete bone-tray contact. The present study compares the final contact area of a cementless tray as a function of the initial osteotomy flatness. METHODS: Eight surgeons prepared 14 cadaveric knees for cementless total knee replacement using standard instrumentation. The topography of each osteotomy was captured with a laser scanner; 3-dimensional computer models of the surfaces were generated. After scanning each tibia, the surgeons implanted cementless tibial trays using a manual impactor. Each tibia was then dissected, embedded in mounting resin, and sectioned. The sectioned blocks were observed under stereomicroscopy to identify points of bone-tray contact which were incorporated into the 3-dimensional models. Maps were then generated illustrating depicting contacting and noncontacting areas. RESULTS: The mean initial flatness of all specimens was 1.1 ± 0.35 mm. After impaction, 79.4% ± 0.3% of the surface had established bony contact. Of the noncontacting areas, 17.6% were within 0.3 mm of the tray. Only 2.6% of the surface was at distances reported to impede ingrowth. Noncontacting areas were typically located centrally. A trend in decreasing percent contact area with increased flatness tolerance was observed (R2 = 0.605). CONCLUSION: (1) There is an inverse correlation between the flatness of the tibial osteotomy and the percentage of the bony surface in contact with underside of the tibial tray. (2) Almost all tray-tibia contact is generated during implantation through flattening of elevated features on the tibial surface. (3) Gaps between the tray and the tibia are consistently located in the central regions of the osteotomy proximal to the medullary canal.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Articulación de la Rodilla/cirugía , Osteotomía , Tibia/cirugía
6.
J Arthroplasty ; 35(8): 2254-2258, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32307292

RESUMEN

BACKGROUND: We evaluated bone volume fraction in retrieved acetabular shells with 2 types of porous coatings: (1) titanium fiber mesh (HG) components and (2) tantalum metal coating (TM) components. METHODS: Eight HG shells were matched to 8 TM shells for patient age, body mass index, and gender. The mean age at index surgery was 69 (51-82) years, mean body mass index was 28 (21-40), and patients were evenly divided between male and female (4:4). The length of implantation was 40 (16-96) months for the TM group and 156 (108-216) months for the HG group. Shells were embedded and two 5-mm thick cross-sections were cut through the apex of each component for backscatter scanning electron microscopy assessment. Backscatter scanning electron microscopy images were segmented to threshold for metal, bone, and available space for ingrowth. Slices were assessed regionally for ingrowth at the rim, equator, and pole of the acetabular shell. Differences were assessed using general estimating equations, and P values were adjusted for multiple comparisons using the Holm-Bonferroni step-down procedure. RESULTS: The mean bone volume fraction was 21 ± 17% for the HG shell and 7 ± 4% for the TM shell (P < .0001). The rim and pole regions both had less bone ingrowth than the equator. No association was found between bone ingrowth and length of implantation for either design. CONCLUSION: Adequate bone ingrowth is a requirement for successful biological fixation, but the amount of ingrowth may not be a driving factor. Both implants studied had successful outcomes and long-term fixation despite the observation of low amounts of ingrowth.


Asunto(s)
Acetábulo , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Microscopía Electrónica de Rastreo , Porosidad , Diseño de Prótesis , Tantalio
7.
J Shoulder Elbow Surg ; 25(2): 246-55, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26422526

RESUMEN

BACKGROUND: Glenoid components often cause total shoulder arthroplasty failure. This study examines short-term to midterm radiographic and clinical results of a hybrid glenoid component with 3 cemented peripheral pegs and a central peg, which allows biologic fixation with use of native humeral head autograft. METHODS: In 4 years, 80 glenoid components were implanted during primary total shoulder arthroplasty with at least 2-year follow-up data. Within 12 months, 4 shoulders were revised and excluded from final analyses. Seven patients did not complete their questionnaires. Outcomes data included the American Shoulder and Elbow Surgeons (ASES) questionnaire, Constant score, and satisfaction score. A shoulder and elbow fellowship-trained surgeon, not involved in the care of these patients, analyzed radiographs for radiolucent lines, glenoid seating, and radiodensity in between the flanges of the central peg. RESULTS: Only 1 of 80 shoulders was revised for aseptic glenoid loosening. At final follow-up, 81.6% had a radiolucency grade of 0 or 1. Nearly 90% had a glenoid seating grade of A or B. Grade 2 or 3 bone around the central peg was seen in 88.2%. No statistical association existed between Walch glenoid types and radiolucency grades, bone grades around the central peg, perfect radiolucency grade, seating grade, and grade 3 bone around the central peg. There was significant improvement in mean ASES score, adjusted ASES pain score, Constant score, and satisfaction score as well as in forward flexion, abduction, and external rotation. CONCLUSIONS: The hybrid glenoid can produce stable radiographic and clinical outcomes at short- to medium-term follow-up.


Asunto(s)
Artroplastia de Reemplazo/instrumentación , Prótesis Articulares , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo/métodos , Femenino , Estudios de Seguimiento , Cavidad Glenoidea/diagnóstico por imagen , Humanos , Cabeza Humeral/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Polietileno , Radiografía , Rango del Movimiento Articular , Reoperación , Estudios Retrospectivos , Articulación del Hombro/fisiopatología , Dolor de Hombro/cirugía , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
8.
Int Orthop ; 40(11): 2355-2363, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27506572

RESUMEN

AIM OF THE STUDY: To assess the clinical and computed tomography (CT) outcomes of shoulder replacement with a novel bone ingrowth all-polyethylene glenoid component (APGC). METHODS: Twenty-eight patients (30 shoulders) with osteoarthritis, mean age 62.3 years (range, 45-75), were implanted with the novel component between 2011 and 2013. Patients were evaluated by active range of motion (ROM), Constant-Murley score (CMS), simple shoulder test (SST), X-rays, and multidetector CT at two months and at a mean follow-up of 31 months (range, 24-39). Early and late follow-up CT scans were available for 21/30 shoulders. RESULTS: Median ROM increased from 105 to 160° for anterior elevation, from 100 to 160° for lateral elevation, from 20 to 40° for external rotation, and from 2 to 10 points for internal rotation (all p < 0.001). CMS rose from 30 to 80.5 points and SST from 2.5 to 11 (both p < 0.0001). None of the glenoid components migrated. Progressive radiolucency was seen in 28/30 shoulders. There was a strong correlation between greater bone ingrowth (median Arnold score: 7) and lower radiolucency score (median Yian score: 2) at the last follow-up (p < 0.001). Osteolysis around the central peg was seen in two shoulders. There was no correlation between clinical scores and CT findings (p >0.05). DISCUSSION: The partially cemented glenoid component for TSR assessed in this study resulted in satisfactory shoulder function at an early follow-up. The glenoid prosthesis was stable, with few radiolucent lines and good central peg bone ingrowth. CONCLUSIONS: The satisfactory bone ingrowth documented on CT is encouraging and supports the use of the new prosthesis. Long-term follow-up studies can confirm if this device represents a rational alternative to fully cemented polyethylene glenoids.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Prótesis Articulares , Oseointegración , Osteoartritis/cirugía , Escápula/cirugía , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico por imagen , Osteoartritis/fisiopatología , Polietileno , Estudios Prospectivos , Diseño de Prótesis , Escápula/diagnóstico por imagen , Escápula/fisiopatología , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Tomografía Computarizada por Rayos X
9.
Eur Spine J ; 24(11): 2530-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26026473

RESUMEN

PURPOSE: To evaluate the osteoconductivity and the bonding strength of the newly developed interbody cage covered with the porous titanium sheet (porous Ti cage) to vertebral bodies in a sheep model. METHODS: Twelve sheep underwent anterior lumbar interbody fusion at L2-3 and L4-5 using either the new porous Ti cages (Group-P) or conventional Ti cages with autogenous iliac bone (Group-C). The animals were euthanized at 2 or 4 months postoperatively and subjected to radiological, biomechanical, and histological examinations. RESULTS: Computed tomography analyses showed that the ratio of bone contact area in Group-P was significantly increased at 4 months compared with that at 2 months (p = 0.01). Although the ratio of bone contact area in Group-C was significantly higher than Group-P at 2 months (p < 0.001), there was no statistically significant difference between the two groups at 4 months. Biomechanical test showed that there was no significant difference in bonding strength between the two groups at either 2 or 4 months. Histological analyses revealed that the bone apposition ratio increased significantly with time in Group-P (p < 0.001). Although Group-C showed significantly higher bone apposition ratio than Group-P at 2 months (p = 0.001), there was no statistical difference between the two groups at 4 months. CONCLUSIONS: There was bone ingrowth into the porous Ti sheet, and bonding capacity of the porous Ti cage to the host bone increased with time. However, the speed of union to the bone with a porous Ti cage was marginally lower than a conventional cage along with an autogenous bone graft. Although it needs further experiment with a larger sample size, the results of the current study suggested that this material could achieve interbody fusion without the need for bone grafts.


Asunto(s)
Vértebras Lumbares/cirugía , Oseointegración , Fusión Vertebral/métodos , Titanio , Animales , Trasplante Óseo , Ilion/trasplante , Modelos Anatómicos , Porosidad , Ovinos , Fusión Vertebral/instrumentación
10.
J Shoulder Elbow Surg ; 24(9): 1458-62, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25842027

RESUMEN

BACKGROUND: Although total shoulder arthroplasty has demonstrated better clinical outcomes than hemiarthroplasty, glenoid component loosening is a common complication. Recently, a novel partially cemented all-polyethylene fluted central peg bone-ingrowth component was introduced. METHODS: Forty-two consecutive total shoulder arthroplasties from 2003 to 2007 performed by a single surgeon were evaluated radiographically and clinically with American Shoulder and Elbow Surgeons (ASES) scores and range of motion. RESULTS: The average follow-up was 80 months (63-114); the average forward elevation improved from 107° to 137°, and external rotation improved from 30° to 37° at the latest follow-up. The average ASES score improved from 50 to 84. There was a strong correlation with the mean peripheral peg lucent line score (Lazarus score), which was 0.81, with the mean anchor peg lucent line score, which was 0.50 (P < .001). An analysis of polyethylene before and after cross-linking revealed a strong correlation between components with cross-linking and the Lazarus scores and the central fluted peg scores. Overall, there was 97% survivorship at 80 months. On radiographs, 81% of the central fluted pegs had complete incorporation with no lucent lines. These lucent lines correlated with lower ASES scores, suggesting that loosening of the glenoid decreases functional outcome. CONCLUSION: Care should be taken in preparing the central fluted peg as perforation of the vault can lead to central flute peg lucent line formation, whereas perforation of the peripheral pegs does not seem to negatively affect the outcome.


Asunto(s)
Artroplastia de Reemplazo , Prótesis Articulares , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles , Cementación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polietileno , Falla de Prótesis , Escápula/cirugía , Resultado del Tratamiento
11.
J Arthroplasty ; 30(4): 706-12, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25515944

RESUMEN

The effect of factors such as design, alloy and coating type on bony or fibrous tissue ingrowth was evaluated in a study of 423 retrieved cementless acetabular shells representing 16 shell designs. Small-beaded (250µm) porous coatings, either with or without hydroxyapatite (HA) coatings, proved to be the superior porous surface for bone ingrowth. Small-beaded shells that were Duofix coated had predominantly fibrous tissue ingrowth. In addition to bead size, alloy type and surface type have significant effect on bone ingrowth. In contrast, there is no significant association between bone ingrowth and time in situ, with most bone ingrowth occurring early. Although roughened, press-fit shells have acceptable clinical and Registry data, they showed some of the lowest ingrowth/ongrowth scores of all the shells tested.


Asunto(s)
Acetábulo/cirugía , Prótesis de Cadera , Oseointegración , Cementación , Remoción de Dispositivos , Femenino , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
J Arthroplasty ; 30(6): 1073-8, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25743106

RESUMEN

Contemporary total knee designs incorporating highly porous metallic surfaces have demonstrated promising clinical outcomes. However, stiffness differences between modular and monoblock porous tantalum tibial trays may affect bone ingrowth. This study investigated effect of implant design, spatial location and clinical factors on bone ingrowth. Three modular and twenty-one monoblock retrieved porous tantalum tibial trays were evaluated for bone ingrowth. Nonparametric statistical tests were used to investigate differences in bone ingrowth by implant design, tray spatial location, substrate depth and clinical factors. Modular trays (5.3 ± 3.2%) exhibited higher bone ingrowth than monoblock trays (1.6 ± 1.9%, P = 0.032). Bone ingrowth in both designs was highest in the initial 500 µm from the surface. Implantation time was positively correlated with bone ingrowth for monoblock trays.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Diseño de Prótesis/métodos , Tantalio/química , Tibia/cirugía , Adulto , Anciano , Desarrollo Óseo , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Porosidad , Reoperación , Estadísticas no Paramétricas
13.
J Arthroplasty ; 30(4): 607-10, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25443360

RESUMEN

It is still challenging to perform successful cementless cup fixation during total hip arthroplasty for hip dysplasia. In this multicenter study we evaluated the clinical results of porous tantalum modular acetabular cups (TM cups) in 45 dysplastic hips with a mean follow-up period of 9.8 years. The mean Japanese Orthopaedic Association hip score improved from 48.2 preoperatively to 92.1 at the most recent follow-up. All of the cups were radiographically stable with no evidence of progressive radiolucencies or osteolysis regardless of bone grafting. Sixteen hips with bone grafts showed the integration of grafted bone without any radiolucencies. There were no revisions of TM cups. The use of TM cups for dysplastic hips provided satisfactory 10-year clinical and radiographic results.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Luxación de la Cadera/cirugía , Prótesis de Cadera , Tantalio , Adulto , Anciano , Trasplante Óseo , Femenino , Estudios de Seguimiento , Humanos , Japón , Masculino , Persona de Mediana Edad , Porosidad , Diseño de Prótesis , Falla de Prótesis
14.
J Arthroplasty ; 30(5): 835-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25637474

RESUMEN

Stem fixation is difficult to achieve in severe proximal bone loss in revision hip surgery. In this study, we sought to present the results of distally-locked stem with screws (HUCKESTEP HIP stem) in 21 revision hips with mean follow-up period of 15 years. The preoperative mean Japanese Orthopaedic Association hip score had improved from 54 to 75 points. Further revisions were required for 2 stems, in one because of infection and the other because of screws fracture and subsidence. With removal of the stem for any reason as an end-point, the cumulative survival at 15 years was 90.4%. While this study had small number, the use of this interlocking stem for revision hips with extensive proximal bone defects provided satisfactory 15-year clinical and radiographic results.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Adulto , Anciano , Resorción Ósea/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación , Resultado del Tratamiento
15.
J Arthroplasty ; 30(3): 484-8, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25540993

RESUMEN

Modification of titanium oxide by multiphase anodic spark deposition (ASD) has the potential to increase bioactivity and hasten osseointegration and biological fixation in uncemented arthroplasty. This study assessed the in vivo performance of control (Ti), plasma-sprayed HA-coated (TiHA) and ASD (Biospark) treated (TiAn) porous titanium implants with a solid core using a standard uncemented implant fixation sheep model. Cortical interfacial shear-strength and bone ingrowth in cortical and cancellous sites were quantified following 12 weeks in situ. Ultimate shear-strength for the Ti, TiHA and TiAn coatings was 33±9.5, 35.4±8.4 and 33.8±7.8 MPa, respectively, which was limited by coating delamination. ASD treatment was associated with significantly higher mean bone ingrowth at both sites. These results support the osteoconductive potential of the BioSpark treatment of porous titanium.


Asunto(s)
Oseointegración , Prótesis e Implantes , Animales , Materiales Biocompatibles Revestidos , Masculino , Modelos Animales , Oseointegración/fisiología , Porosidad , Resistencia al Corte , Ovinos , Titanio
16.
Acta Biomater ; 177: 243-252, 2024 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-38367656

RESUMEN

Porous structures are frequently used in surgical implants to strengthen the interlocking power produced by bone ingrowth. Therefore, we aimed to elucidate the mechanism underlying bone ingrowth into a porous structure accompanied by vascularization. A nonbioactive polyetheretherketone implant with a 3D-printed porous structure was prepared and implanted in a bone hole created in the tibias of rabbits. We observed bone ingrowth in the same individual specimens immediately and at 2, 4, 8, and 12 weeks post-implantation using in-vivo computed tomography (CT). Furthermore, a detailed evaluation with blood vessels of each specimen at 2, 4, and 12 weeks was performed with ex-vivo CT and histological specimen. Additional histological evaluation was performed using thin sections of an implant made with thermoplastic polyurethane having the same structure. As a result, the bone invasion began after four weeks, when the construction of fibrous tissue and the spread of new blood vessels within the voids matured. As the bone matured in the load-bearing area, new blood vessels outside the bone matrix regressed. This longitudinal evaluation study suggests that preceding fibrogenesis and vascularization may be key in developing bone ingrowth. STATEMENT OF SIGNIFICANCE: A porous structure is an essential structure for dental and orthopedic implants because it provides strong fixation through bone invasion. Although it was known that vascularization was involved in this, the details were not known. This in vivo study revealed that in order for bone ingrowth to begin, a preparatory period of approximately 4 weeks was required to establish blood flow inside and outside the implant. Furthermore, it was confirmed that by spreading the fibrous structure in advance, it has an advantageous effect on the migration of cells involved in the formation of bones and blood vessels. We pointed out that it is necessary to consider fibrogenesis and vascularization when creating future implants.


Asunto(s)
Huesos , Prótesis e Implantes , Animales , Conejos , Porosidad , Polietilenglicoles/química , Cetonas/farmacología , Cetonas/química , Neovascularización Patológica , Titanio/química , Oseointegración/fisiología
17.
Comput Biol Med ; 175: 108551, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38703546

RESUMEN

The long-term performance of porous coated tibial implants for total ankle replacement (TAR) primarily depends on the extent of bone ingrowth at the bone-implant interface. Although attempts were made for primary fixation for immediate post-operative stability, no investigation was conducted on secondary fixation. The aim of this study is to assess bone ingrowth around the porous beaded coated tibial implant for TAR using a mechanoregulatory algorithm. A realistic macroscale finite element (FE) model of the implanted tibia was developed based on computer tomography (CT) data to assess implant-bone micromotions and coupled with microscale FE models of the implant-bone interface to predict bone ingrowth around tibial implant for TAR. The macroscale FE model was subjected to three near physiological loading conditions to evaluate the site-specific implant-bone micromotion, which were then incorporated into the corresponding microscale model to mimic the near physiological loading conditions. Results of the study demonstrated that the implant experienced tangential micromotion ranged from 0 to 71 µm with a mean of 3.871 µm. Tissue differentiation results revealed that bone ingrowth across the implant ranged from 44 to 96 %, with a mean of around 70 %. The average Young's modulus of the inter-bead tissue layer varied from 1444 to 4180 MPa around the different regions of the implant. The analysis postulates that when peak micromotion touches 30 µm around different regions of the implant, it leads to pronounced fibrous tissues on the implant surface. The highest amount of bone ingrowth was observed in the central regions, and poor bone ingrowth was seen in the anterior parts of the implant, which indicate improper osseointegration around this region. This macro-micro mechanical FE framework can be extended to improve the implant design to enhance the bone ingrowth and in future to develop porous lattice-structured implants to predict and enhance osseointegration around the implant.


Asunto(s)
Algoritmos , Artroplastia de Reemplazo de Tobillo , Análisis de Elementos Finitos , Tibia , Humanos , Tibia/cirugía , Tibia/diagnóstico por imagen , Artroplastia de Reemplazo de Tobillo/instrumentación , Tomografía Computarizada por Rayos X , Modelos Biológicos , Oseointegración/fisiología , Interfase Hueso-Implante/diagnóstico por imagen , Prótesis Articulares
18.
Am J Transl Res ; 15(1): 114-124, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36777855

RESUMEN

Three-dimensional (3D) printed titanium (Ti-6Al-4V alloy) cages are widely used for spinal fusion applications. However, the structural design and shape of the cages are a major determinant of the optimal clinical outcome. In this study, we constructed a newly designed 3D-printed helical-shaped titanium cage (HTC) with a flexible body, and compared its healing and fusion efficacy in cervical vertebral defects after corpectomy in rabbits to that of a 3D-printed traditional titanium cage (TTC). We performed radiological examinations 1 and 16 weeks after TTC and HTC implantation. We assessed bone ingrowth in TTC and HTC using micro-computed tomography (micro-CT) and histological staining of tissue sections at 16 weeks. The radiographic data showed that the HTC-implanted group had better restoration of vertebral height than the TTC group, indicating a lower risk of cage subsidence. The micro-CT and histological observations showed that HTC promoted bone regeneration and osseointegration more effectively than TTC. Histomorphometry further revealed significant new bone formation in the HTC group compared to the TTC group. These findings demonstrate that HTC has better healing and bone fusion effects than TTC in cervical vertebral defects in rabbits, indicating its potential clinical value.

19.
J Biomed Mater Res B Appl Biomater ; 111(2): 442-452, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36111647

RESUMEN

A novel biomimetic artificial intervertebral disc (bioAID) for the cervical spine was developed, containing a hydrogel core representing the nucleus pulposus, an UHMWPE fiber jacket as annulus fibrosis, and titanium endplates with pins for mechanical fixation. Osseointegration of the UHMWPE fibers to adjacent bone structures is required to achieve proper biomimetic behavior and to provide long-term stability. Therefore, the aim of this study was to assess the osteoconductivity of several surface modifications of UHMWPE fabrics, 2D weft-knitted, using non-treated UHMWPE fibers (N), plasma treated UHMWPE fibers (PT), 10% hydroxy apatite (HA) loaded UHMWPE fibers (10%HA), plasma treated 10%HA UHMWPE fibers (PT-10%HA), 15%HA loaded UHMWPE fibers (15%HA) and plasma treated 15%HA UHMWPE fibers (PT-15%HA). Scanning electron microscopy (SEM) was used for surface characterization. Biological effects were assessed by evaluating initial cell attachment (SEM, DNA content), metabolic activity (PrestoBlue assay), proliferation, differentiation (alkaline phosphatase activity) and mineralization (energy dispersive x-ray, EDX analysis) using human bone marrow stromal cells. Plasma treated samples showed increased initial cell attachment, indicating the importance of hydrophilicity for cell attachment. However, incorporation only of HA or plasma treatment alone was not sufficient to result in upregulated alkaline phosphatase activity (ALP) activity. Combining HA loaded fibers with plasma treatment showed a combined effect, leading to increased cell attachment and upregulated ALP activity. Based on these results, combination of HA loaded UHMWPE fibers and plasma treatment provided the most promising fabric surface for facilitating bone ingrowth.


Asunto(s)
Fosfatasa Alcalina , Polietileno , Humanos , Polietilenos/química , Apatitas , Prótesis e Implantes
20.
Biomater Adv ; 155: 213697, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37979439

RESUMEN

The additive manufacturing of titanium into porous geometries offers a means to generate low-stiffness endosseous implants with a greater surface area available for osseointegration. In this work, selective laser melting was used to produce gyroid-based scaffolds with a uniform pore size of 300 µm or functionally graded pore size from 600 µm to 300 µm. Initial in vitro assessment with Saos-2 cells showed favourable cell proliferation at pore sizes of 300 and 600 µm. Following implantation into rabbit tibiae, early histological observations at four weeks indicated some residual inflammation alongside neovessel infiltration into the scaffold interior and some early apposition of mineralized bone tissue. At twelve weeks, both scaffolds were filled with a mixture of adipocyte-rich marrow, micro-capillaries, and mineralized bone tissue. X-ray microcomputed tomography showed a higher bone volume fraction (BV/TV) and percentage of bone-implant contact (BIC) in the implants with 300 µm pores than in the functionally graded specimens. In functionally graded specimens, localized BV/TV measurement was observed to be higher in the innermost region containing smaller pores (estimated at 300-400 µm) than in larger pores at the implant exterior. The unit cell topology of the porous implant was also observed to guide the direction of bone ingrowth by conducting along the implant struts. These results suggest that in vivo experimentation is necessary alongside parametric optimization of functionally graded porous implants to predict short-term and long-term bone apposition.


Asunto(s)
Oseointegración , Titanio , Animales , Conejos , Porosidad , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS