Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Protein Expr Purif ; 203: 106217, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36529448

RESUMEN

For recombinantly produced monoclonal antibody (mAb), charge variants including acidic and basic species are common heterogeneities. For characterization purpose, sufficient amount of acidic and basic species with high purity is needed. In this work, we developed an approach that allows for continuous separating and collecting of acidic and basic charge variants. First, with batch-mode cation exchange (CEX) chromatography, the load density and linear salt gradient elution conditions under which good separation of both charge variants can be achieved were determined. Next, a stepwise elution protocol was developed based on the linear gradient elution. Finally, acidic and basic charge variants were persistently produced under stepwise elution using a customized twin-column continuous chromatography system. This approach allows acidic and basic charge variants with high purity (i.e., >90%) to be efficiently generated in sufficient amount, which greatly facilitates the necessary characterization of these mAb variants.


Asunto(s)
Anticuerpos Monoclonales , Cloruro de Sodio , Cromatografía por Intercambio Iónico/métodos , Cloruro de Sodio/química , Anticuerpos Monoclonales/química , Cationes/química
2.
Biotechnol Bioeng ; 119(8): 2152-2166, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35470430

RESUMEN

In this study, we demonstrated the first, to our knowledge, integrated continuous bioprocess (ICB) designed for the production of acid-sensitive monoclonal antibodies, prone to aggregate at low pH, on pilot scale. A high cell density perfusion culture, stably maintained at 100 × 106 cells/ml, was integrated with the downstream process, consisting of a capture step with the recently developed Protein A ligand, ZCa ; a solvent/detergent-based virus inactivation; and two ion-exchange chromatography steps. The use of a mild pH in the downstream process makes this ICB suitable for the purification of acid-sensitive monoclonal antibodies. Integration and automation of the downstream process were achieved using the Orbit software, and the same equipment and control system were used in initial small-scale trials and the pilot-scale downstream process. High recovery yields of around 90% and a productivity close to 1 g purified antibody/L/day were achieved, with a stable glycosylation pattern and efficient removal of impurities, such as host cell proteins and DNA. Finally, negligible levels of antibody aggregates were detected owing to the mild conditions used throughout the process. The present work paves the way for future industrial-scale integrated continuous biomanufacturing of all types of antibodies, regardless of acid stability.


Asunto(s)
Anticuerpos Monoclonales , Animales , Anticuerpos Monoclonales/biosíntesis , Anticuerpos Monoclonales/química , Reactores Biológicos , Células CHO , Cricetinae , Cricetulus , Proteína Estafilocócica A/química
3.
Biotechnol Bioeng ; 118(9): 3420-3434, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33755192

RESUMEN

The increasing demand for efficient and robust processes in the purification of monoclonal antibodies (mAbs) has recently brought frontal chromatography to the forefront. Applied during the polishing step, it enables the removal of high molecular weight aggregates from the target product, achieving high purities. Typically, this process is operated in batch using a single column, which makes it intrinsically subjected to a purity-yield tradeoff. This means that high purities can only be achieved at the cost of lowering the product yield and vice versa. Recently, a two-column continuous implementation of frontal chromatography, referred to as Flow2, was developed. Despite being able of alleviating the purity-yield tradeoff typical of batch operations, the increase in the number of process parameters complicates its optimal design, with the risk of not exploiting its full potential. In this study, we developed an ad hoc design procedure (DP) suitable for the optimization of both batch frontal chromatography and Flow2 in terms of purity, yield, and productivity. This procedure provided similar results as a multiobjective optimization based on genetic algorithm but with lower computational effort. Then, batch and Flow2 operated at their optimal conditions were compared. Besides showing a more favorable Pareto front of yield and productivity at a specified purity, the Flow2 process demonstrated improved robustness compared to the batch process with respect to modifications in the loading linear velocity, washing buffer ionic strength and loading time, thus providing an appealing operation for integrated processes.


Asunto(s)
Anticuerpos Monoclonales , Proteína Estafilocócica A/química , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/aislamiento & purificación , Cromatografía de Afinidad , Cromatografía por Intercambio Iónico
4.
Biotechnol Bioeng ; 118(1): 164-174, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32910459

RESUMEN

An efficient and consistent method of monoclonal antibody (mAb) purification can improve process productivity and product consistency. Although protein A chromatography removes most host-cell proteins (HCPs), mAb aggregates and the remaining HCPs are challenging to remove in a typical bind-and-elute cation-exchange chromatography (CEX) polishing step. A variant of the bind-and-elute mode is the displacement mode, which allows strongly binding impurities to be preferentially retained and significantly improves resin utilization. Improved resin utilization renders displacement chromatography particularly suitable in continuous chromatography operations. In this study we demonstrate and exploit sample displacement between a mAb and impurities present at low prevalence (0.002%-1.4%) using different multicolumn designs and recycling. Aggregate displacement depends on the residence time, sample concentration, and solution environment, the latter by enhancing the differences between the binding affinities of the product and the impurities. Displacement among the mAb and low-prevalence HCPs resulted in an effectively bimodal-like distribution of HCPs along the length of a multi-column system, with the mAb separating the relatively more basic group of HCPs from those that are more acidic. Our findings demonstrate that displacement of low-prevalence impurities along multiple CEX columns allows for selective separation of mAb aggregates and HCPs that persist through protein A chromatography.


Asunto(s)
Anticuerpos Monoclonales/aislamiento & purificación , Cromatografía por Intercambio Iónico , Agregado de Proteínas , Animales , Anticuerpos Monoclonales/química , Células CHO , Cricetulus
5.
Biotechnol Bioeng ; 118(9): 3522-3532, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33818758

RESUMEN

Virus-based biologicals are one of the most promising biopharmaceuticals of the 21st century medicine and play a significant role in the development of innovative therapeutic, prophylactic, and clinical applications. Oncolytic virus manufacturing scale can range from 5 L in research and development up to 50 L for clinical studies and reach hundreds of liters for commercial scale. The inherent productivity and high integration potential of periodic counter-current chromatography (PCC) offer a transversal solution to decrease equipment footprint and the reduction of several non-value-added unit operations. We report on the design of an efficient PCC process applied to the intermediate purification of oncolytic adenovirus. The developed ion-exchange chromatographic purification method was carried out using a four-column setup for three different scenarios: (i) variation in the feedstock, (ii) potential use of a post-load washing step to improve virus recovery, and (iii) stability during extended operation. Obtained virus recoveries (57%-86%) and impurity reductions (>80% DNA, and >70% total protein) match or overcome batch purification. Regarding process stability and automation, our results show that not only the dynamic control strategy used is able to suppress perturbations in the sample inlet but also allows for unattended operation in the case of ion exchange capture.


Asunto(s)
Productos Biológicos/aislamiento & purificación , Virus Oncolíticos/aislamiento & purificación , Células A549 , Distribución en Contracorriente , Humanos
6.
Biotechnol Bioeng ; 118(9): 3313-3322, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33480439

RESUMEN

Continuous capture with affinity chromatography is one of the most important units for continuous manufacturing of monoclonal antibody (mAb). Due to the complexity of three-column periodic counter-current chromatography (3C-PCC), three approaches (experimental, model-based, and simplified approaches) were studied for process development and optimization. The effects of residence time for interconnected load (RT C ), breakthrough percentage of the first column for interconnected load (s) and feed protein concentration (c 0 ) on productivity and capacity utilization were focused. The model-based approach was found superior to the experimental approach in process optimization and evaluation. Two phases of productivity were observed and the optimal RT C for the maximum productivity was located at the boundary of the two phases. The comprehensive effects of the operating parameters (RT C , s, and c 0 ) were evaluated by the model-based approach, and the operation space was predicted. The best performance of 34.5 g/L/h productivity and 97.6% capacity utilization were attained for MabSelect SuRe LX resin under 5 g/L concentration at RT C = 2.8 min and s = 87.5%. Moreover, a simplified approach was suggested to obtain the optimal RT C for the maximum productivity. The results demonstrated that model-assisted tools are useful to determine the optimum conditions for 3C-PCC continuous capture with high productivity and capacity utilization.


Asunto(s)
Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/aislamiento & purificación , Cromatografía de Afinidad , Distribución en Contracorriente
7.
Biotechnol Bioeng ; 118(3): 1262-1272, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33283261

RESUMEN

A new method was proposed for increasing the capture chromatography process efficiency, linear flow-velocity gradient (LFG). The method uses a linear decreasing flow-velocity gradient with time during the sample loading. The initial flow velocity, the final flow velocity and the gradient time are the parameters to be tuned. We have developed a method for determining these parameters by using the total column capacity and the total loaded amount as a function of time. The capacity can be calculated by using the relationships between dynamic binding capacity (DBC) and residence time. By leveraging the capacity, loading amount, and the required conditions, the optimum LFG can be designed. The method was verified by ion-exchange and protein A chromatography of monoclonal antibodies (mAbs). A two-fold increase in the productivity during the sample loading was possible by LFG compared with the constant flow-velocity (CF) operation. LFG was also applied to a 4-column continuous process. The simulation showed that the cost of resin per unit amount of processed mAbs can be reduced by 13% while 1.4 times enhancement in productivity was preserved after optimization by LFG compared to CF. The process efficiency improvement is more pronounced when the isotherm is highly favorable and the loading volume is large.


Asunto(s)
Anticuerpos Monoclonales , Cromatografía de Afinidad , Simulación por Computador , Modelos Químicos , Proteína Estafilocócica A/química , Animales , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/aislamiento & purificación
8.
Molecules ; 26(15)2021 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-34361839

RESUMEN

The market of biomolecules with therapeutic scopes, including peptides, is continuously expanding. The interest towards this class of pharmaceuticals is stimulated by the broad range of bioactivities that peptides can trigger in the human body. The main production methods to obtain peptides are enzymatic hydrolysis, microbial fermentation, recombinant approach and, especially, chemical synthesis. None of these methods, however, produce exclusively the target product. Other species represent impurities that, for safety and pharmaceutical quality reasons, must be removed. The remarkable production volumes of peptide mixtures have generated a strong interest towards the purification procedures, particularly due to their relevant impact on the manufacturing costs. The purification method of choice is mainly preparative liquid chromatography, because of its flexibility, which allows one to choose case-by-case the experimental conditions that most suitably fit that particular purification problem. Different modes of chromatography that can cover almost every separation case are reviewed in this article. Additionally, an outlook to a very recent continuous chromatographic process (namely Multicolumn Countercurrent Solvent Gradient Purification, MCSGP) and future perspectives regarding purification strategies will be considered at the end of this review.


Asunto(s)
Péptidos/química , Péptidos/síntesis química , Péptidos/aislamiento & purificación , Cromatografía Liquida , Humanos , Péptidos/uso terapéutico
9.
Biotechnol Bioeng ; 117(3): 646-653, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31784975

RESUMEN

Continuous countercurrent tangential chromatography (CCTC) enables steady-state continuous bioprocessing with low-pressure operation and high productivity. CCTC has been applied to initial capture of monoclonal antibodies (mAb) from clarified cell culture harvest and postcapture polishing of mAb; however, these studies were performed with commercial chromatography resins designed for conventional column chromatography. In this study, a small particle size prototype agarose resin (20-25 µm) with lower cross-linking was co-developed with industrial partner Purolite and tested with CCTC. Due to increased binding capacity and faster kinetics, the resulting CCTC process showed more than a 2X increase in productivity, and a 2X reduction in buffer consumption over commercial protein A resins used in previous CCTC studies, as well as more than a 10X productivity increase versus conventional column operation. Single-pass tangential flow filtration was integrated with the CCTC system, enabling simple control of eluate concentration. A scale-up exercise was conducted to provide a quantitative comparison of CCTC and batch column chromatography. These results clearly demonstrate opportunities for using otherwise unpackable soft small particle size resins with CCTC as the core of a continuous bioprocessing platform.


Asunto(s)
Anticuerpos Monoclonales/aislamiento & purificación , Reactores Biológicos , Distribución en Contracorriente/métodos , Proteína Estafilocócica A , Animales , Células CHO , Cricetinae , Cricetulus , Proteína Estafilocócica A/química , Proteína Estafilocócica A/metabolismo
10.
Biotechnol Bioeng ; 117(3): 673-686, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31788777

RESUMEN

Control of column loading in Protein A chromatography is a crucial part of development of robust and flexible process platforms for continuous production of monoclonal antibody (mAb) products. In this paper, we propose a control system that uses near infrared spectroscopy (NIRS) flow cells to accomplish the above. Two applications have been demonstrated using a periodic counter-current continuous chromatography setup. The first application involves use of single NIR flow cell before the inlet of the loading column to measure the concentration of mAb in the harvested broth. Measurement was in real-time (every 3 s) and within ±0.05 mg/ml, significantly better than making UV-based concentration estimations. The second application involved use of an additional NIR flow cell at the outlet of the loading column to measure column breakthrough in real time. The concentration data was transferred to a Python-based monitoring and control algorithm layered over a Cadence BioSMB system. The program could successfully run a three-column periodic counter current method on the BioSMB whereas controlling loading to ensure optimal resin utilization in each loading cycle phase based on precharacterized dynamic binding capacity models, whereas maintaining periodic elutions. The system was tested with multiple perturbations in harvest concentration, modeled after deviations that could arise downstream of a perfusion cell culture system. The results show that the proposed control is a spectroscopy-based process analytical technology tool that facilitates real time monitoring and control of loading in process chromatography. It is adaptable to any continuous chromatography equipment and is very well suited for implementation in a continuous mAb production train.


Asunto(s)
Anticuerpos Monoclonales , Cromatografía de Afinidad/métodos , Distribución en Contracorriente/métodos , Técnicas Fotoacústicas/métodos , Espectroscopía Infrarroja Corta/métodos , Animales , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/metabolismo , Reactores Biológicos , Células Cultivadas , Diseño de Equipo , Proteína Estafilocócica A/química , Proteína Estafilocócica A/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA