1.
Blood Press ; 31(1): 19-30, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35014940

RESUMEN

PURPOSE: Existing technologies to measure central blood pressure (CBP) intrinsically depend on peripheral pressure or calibration models derived from it. Pharmacological or physiological interventions yielding different central and peripheral responses compromise the accuracy of such methods. We present a high-frame-rate ultrasound technology for cuffless and calibration-free evaluation of BP from the carotid artery. The system uses a pair of single-element ultrasound transducers to capture the arterial diameter and local pulse wave velocity (PWV) for the evaluation of beat-by-beat BP employing a novel biomechanical model. MATERIALS AND METHODS: System's functionality assessment was conducted on eight male subjects (26 ± 4 years, normotensive and no history of cardiovascular risks) by perturbing pressure via short-term moderate lower body negative pressure (LBNP) intervention (-40 mmHg for 1 min). The ability of the system to capture dynamic responses of carotid pressure to LBNP was investigated and compared against the responses of peripheral pressure measured using a continuous BP monitor. RESULTS: While the carotid pressure manifested trends similar to finger measurements during LBNP, the system also captured the differential carotid-to-peripheral pressure response, which corroborates the literature. The carotid diastolic and mean pressures agreed with the finger pressures (limits-of-agreement within ±7 mmHg) and exhibited acceptable uncertainty (mean absolute errors were 2.4 ± 3.5 and 2.6 ± 4.0 mmHg, respectively). Concurrent to the literature, the carotid systolic and pulse pressures (PPs) were significantly lower than those of the finger pressures by 11.1 ± 9.4 and 11.3 ± 8.2 mmHg, respectively (p < .0001). CONCLUSIONS: The study demonstrated the method's potential for providing cuffless and calibration-free pressure measurements while reliably capturing the physiological aspects, such as PP amplification and dynamic pressure responses to intervention.


Asunto(s)
Presión Negativa de la Región Corporal Inferior , Análisis de la Onda del Pulso , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Calibración , Arterias Carótidas/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Masculino , Análisis de la Onda del Pulso/métodos
2.
Comput Methods Programs Biomed ; 194: 105557, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32474251

RESUMEN

BACKGROUND AND OBJECTIVE: The manual measurement of arterial diameter and wall thickness using imaging modalities demand expertise, and the state-of-art automated or semi-automated measurement features are seldom available in the entry-level systems. The advanced ultrasound modalities are expensive, non-scalable, and less favorable for field and resource-constrained settings. In this work, we present a novel method to measure arterial diameter (D), surrogate intima-media thickness (sIMT), and with them their intra-cardiac cycle changes by employing an affordable image-free ultrasound technology. METHODS: The functionality of the method was systematically validated on a simulation testbed, phantoms and, 40 human subjects. The accuracy, agreement, inter-beat, and inter-operator variabilities were quantified. The in-vivo measurement performance of the method was compared against two reference B-mode tools - Carotid Studio and CAROLAB. RESULTS: Simulations revealed that for the A-mode frames with SNR > 10 dB, the proposed method identifies the desired arterial wall interfaces with an RMSE < 20 µm. The RMSE for the diameter and wall thickness measurements from the static phantom were 111 µm and 14 µm, and for the dynamic phantom were 117 µm and 18 µm, respectively. Strong agreement was seen between the in-vivo measurements of the proposed method and the two reference tools. The mean absolute errors against the two references and the inter-beat variability were smaller than 0.18 mm for D and smaller than 36 µm for sIMT measurements. Likewise, the respective inter-observer variabilities were 0.16 ± 0.23 mm and 43 ± 25 µm. CONCLUSION: Acceptable accuracy and repeatability were observed during the validation, that were on a par with the recently reported B-mode techniques in the literature. The technology being real-time, automated, and relatively inexpensive, is promising for field and low-resource settings.


Asunto(s)
Arterias Carótidas , Grosor Intima-Media Carotídeo , Arterias Carótidas/diagnóstico por imagen , Descompresión , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Ultrasonografía