Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51.753
Filtrar
Más filtros

Colección Oncologia Uruguay
Intervalo de año de publicación
1.
Prostate ; 84(2): 203-211, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37876324

RESUMEN

BACKGROUND: To elucidate the changes in activated complement pathway in the fibrous process of benign prostatic hyperplasia (BPH), we analyzed the correlation between complement component expression and histological types of fibrosis using human BPH tissue. METHODS: Fifty-six histological BPH patients who underwent prostate needle biopsy at our institution (mean age 68.6 ± 6.5 years), divided into two histological groups, fibromuscular and fibrous, were compared. Inflammatory cell infiltration in BPH tissue was evaluated by immunohistochemical staining using CD45, with complement expression analysis performed using C3, factor B, and C5b-9 antibody, and the occupancy ratio of the stained region was calculated. Further, correlation between the histological types of fibrous components in BPH tissue and lower urinary tract symptoms questionnaires was analyzed. RESULTS: Twenty-seven (48.2%) and 29 (51.8%) cases were classified in the fibromuscular and fibrous groups, respectively. The proportion of CD45-positive cells in BPH tissue was significantly higher in the fibromuscular group. In complement component analysis, factor B did not significantly differ between groups, while C3 (fibromuscular group; 10.7 ± 8.2%, fibrous group; 16.4 ± 12.7%) and C5b-9 (fibromuscular group; 15.9 ± 6.2%, fibrous group; 17.6 ± 9.2%) were significantly higher in the fibrous group (p = 0.04, p = 0.04, respectively). International Prostate Symptom Score Q5 subscore, indicating slow stream, was significantly higher in the fibrous group (p = 0.04). CONCLUSIONS: In fibrous BPH with abundant fibrosis, the late complement pathway in addition to alternative pathway was activated compared to fibromuscular BPH. These results suggested that the alternative and late complement pathways were involved in the histological fibrous process of BPH.


Asunto(s)
Hiperplasia Prostática , Masculino , Humanos , Persona de Mediana Edad , Anciano , Hiperplasia Prostática/patología , Complejo de Ataque a Membrana del Sistema Complemento/metabolismo , Próstata/patología , Biopsia con Aguja , Fibrosis
2.
Mod Pathol ; 37(3): 100422, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38185250

RESUMEN

Machine learning (ML) models are poised to transform surgical pathology practice. The most successful use attention mechanisms to examine whole slides, identify which areas of tissue are diagnostic, and use them to guide diagnosis. Tissue contaminants, such as floaters, represent unexpected tissue. Although human pathologists are extensively trained to consider and detect tissue contaminants, we examined their impact on ML models. We trained 4 whole-slide models. Three operate in placenta for the following functions: (1) detection of decidual arteriopathy, (2) estimation of gestational age, and (3) classification of macroscopic placental lesions. We also developed a model to detect prostate cancer in needle biopsies. We designed experiments wherein patches of contaminant tissue are randomly sampled from known slides and digitally added to patient slides and measured model performance. We measured the proportion of attention given to contaminants and examined the impact of contaminants in the t-distributed stochastic neighbor embedding feature space. Every model showed performance degradation in response to one or more tissue contaminants. Decidual arteriopathy detection--balanced accuracy decreased from 0.74 to 0.69 ± 0.01 with addition of 1 patch of prostate tissue for every 100 patches of placenta (1% contaminant). Bladder, added at 10% contaminant, raised the mean absolute error in estimating gestational age from 1.626 weeks to 2.371 ± 0.003 weeks. Blood, incorporated into placental sections, induced false-negative diagnoses of intervillous thrombi. Addition of bladder to prostate cancer needle biopsies induced false positives, a selection of high-attention patches, representing 0.033 mm2, and resulted in a 97% false-positive rate when added to needle biopsies. Contaminant patches received attention at or above the rate of the average patch of patient tissue. Tissue contaminants induce errors in modern ML models. The high level of attention given to contaminants indicates a failure to encode biological phenomena. Practitioners should move to quantify and ameliorate this problem.


Asunto(s)
Placenta , Neoplasias de la Próstata , Embarazo , Masculino , Humanos , Femenino , Recién Nacido , Placenta/patología , Aprendizaje Automático , Biopsia con Aguja , Próstata/patología , Neoplasias de la Próstata/patología
3.
J Vasc Interv Radiol ; 35(6): 859-864, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38447771

RESUMEN

PURPOSE: To compare the effectiveness of percutaneous lung biopsy using a patient-mounted needle-driving robotic system with that using a manual insertion of needles under computed tomography (CT) fluoroscopy guidance. MATERIALS AND METHODS: In this institutional review board approved study, the cohort consisted of a series of patients who underwent lung biopsies following the intention-to-treat protocol from September 2022 to September 2023 using robot (n = 15) or manual insertion under single-rotation CT fluoroscopy (n = 66). Patient and procedure characteristics were recorded as well as outcomes. RESULTS: Although age, body mass index, and skin-to-target distance were not statistically different, target size varied (median, 8 mm [interquartile range, 6.5-9.5 mm] for robot vs 12 mm [8-18 mm] for single-rotation CT fluoroscopy; P = .001). No statistical differences were observed in technical success (86.7% [13/15] vs 89.4% [59/66], P = .673), Grade 3 adverse event (AE) (6.7% [1/15] vs 12.1% [8/66], P = .298), procedural time (28 minutes [22-32 minutes] vs 19 minutes [14.3-30.5 minutes], P = .086), and patient radiation dose (3.9 mSv [3.2-5.6 mSv] vs 4.6 mSv [3.3-7.5 mSv], P = .398). In robot-assisted cases, the median angle out of gantry plane was 10° (6.5°-16°), although it was null (0°-5°) for single-rotation CT fluoroscopy (P = .001). CONCLUSIONS: Robot-assisted and single-rotation CT fluoroscopy-guided percutaneous lung biopsies were similar in terms of technical success, diagnostic yield, procedural time, AEs, and radiation dose, although robot allowed for out-of-gantry plane navigation along the needle axis.


Asunto(s)
Biopsia Guiada por Imagen , Pulmón , Radiografía Intervencional , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Fluoroscopía , Persona de Mediana Edad , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/instrumentación , Anciano , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/instrumentación , Pulmón/diagnóstico por imagen , Pulmón/patología , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/instrumentación , Valor Predictivo de las Pruebas , Agujas , Diseño de Equipo , Factores de Tiempo
4.
J Vasc Interv Radiol ; 35(8): 1139-1146.e3, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38685471

RESUMEN

PURPOSE: To compare the risk of hemorrhagic adverse events of transthoracic needle biopsy (TTNB) such as pulmonary hemorrhage and hemoptysis between patients with pulmonary hypertension (PH) and patients without PH. MATERIALS AND METHODS: Database search and citation review of search results were performed for studies reporting frequency of hemorrhagic adverse events of TTNB in adult patients with evidence of PH compared with that in patients undergoing the procedure without evidence of PH. Random-effects meta-analysis was performed for both rates of pulmonary hemorrhage and hemoptysis. RESULTS: A total of 5 studies (encompassing 6,250 patients who underwent 6,684 biopsies) were included. All studies were retrospective and used computed tomography (CT) or echocardiography for identification of signs of PH. Biopsy-related pulmonary hemorrhage was diagnosed radiographically, and postbiopsy hemoptysis was diagnosed by documentation in the medical record. There were no differences found between patients with evidence of PH and those without regarding rates of pulmonary hemorrhage (odds ratio [OR], 1.12 [95% confidence interval {CI}, 0.85-1.47] in studies that used CT to define PH, and OR, 0.88 [95% CI 0.56-1.39] in studies that used echocardiography to define PH). There were also no differences in the rates of hemoptysis (OR, 0.95 [95% CI, 0.46-1.97]). CONCLUSIONS: A systematic review and meta-analysis of the literature did not demonstrate that patients with imaging evidence of PH undergoing TTNB had an increased risk of hemorrhagic adverse events.


Asunto(s)
Hemoptisis , Hemorragia , Hipertensión Pulmonar , Pulmón , Humanos , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/diagnóstico por imagen , Hemorragia/etiología , Hemoptisis/etiología , Pulmón/patología , Pulmón/diagnóstico por imagen , Factores de Riesgo , Biopsia con Aguja/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Oportunidad Relativa , Adulto , Medición de Riesgo
5.
J Vasc Interv Radiol ; 35(5): 780-789.e1, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38355040

RESUMEN

PURPOSE: To validate the sensitivity and specificity of a 3-dimensional (3D) convolutional neural network (CNN) artificial intelligence (AI) software for lung lesion detection and to establish concordance between AI-generated needle paths and those used in actual biopsy procedures. MATERIALS AND METHODS: This was a retrospective study using computed tomography (CT) scans from 3 hospitals. Inclusion criteria were scans with 1-5 nodules of diameter ≥5 mm; exclusion criteria were poor-quality scans or those with nodules measuring <5mm in diameter. In the lesion detection phase, 2,147 nodules from 219 scans were used to develop and train the deep learning 3D-CNN to detect lesions. The 3D-CNN was validated with 235 scans (354 lesions) for sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) analysis. In the path planning phase, Bayesian optimization was used to propose possible needle trajectories for lesion biopsy while avoiding vital structures. Software-proposed needle trajectories were compared with actual biopsy path trajectories from intraprocedural CT scans in 150 patients, with a match defined as an angular deviation of <5° between the 2 trajectories. RESULTS: The model achieved an overall AUC of 97.4% (95% CI, 96.3%-98.2%) for lesion detection, with mean sensitivity of 93.5% and mean specificity of 93.2%. Among the software-proposed needle trajectories, 85.3% were feasible, with 82% matching actual paths and similar performance between supine and prone/oblique patient orientations (P = .311). The mean angular deviation between matching trajectories was 2.30° (SD ± 1.22); the mean path deviation was 2.94 mm (SD ± 1.60). CONCLUSIONS: Segmentation, lesion detection, and path planning for CT-guided lung biopsy using an AI-guided software showed promising results. Future integration with automated robotic systems may pave the way toward fully automated biopsy procedures.


Asunto(s)
Aprendizaje Profundo , Biopsia Guiada por Imagen , Valor Predictivo de las Pruebas , Programas Informáticos , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Biopsia Guiada por Imagen/métodos , Femenino , Masculino , Persona de Mediana Edad , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Anciano , Interpretación de Imagen Radiográfica Asistida por Computador , Teorema de Bayes , Biopsia con Aguja , Pulmón/diagnóstico por imagen , Pulmón/patología
6.
AJR Am J Roentgenol ; 222(2): e2329938, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37910039

RESUMEN

BACKGROUND. Changes in lung parenchyma elasticity in usual interstitial pneumonia (UIP) may increase the risk for complications after percutaneous transthoracic needle biopsy (PTNB) of the lung. OBJECTIVE. The purpose of this article was to investigate the association of UIP findings on CT with complications after PTNB, including pneumothorax, pneumothorax requiring chest tube insertion, and hemoptysis. METHODS. This retrospective single-center study included 4187 patients (mean age, 63.8 ± 11.9 [SD] years; 2513 men, 1674 women) who underwent PTNB between January 2010 and December 2015. Patients were categorized into a UIP group and non-UIP group by review of preprocedural CT. In the UIP group, procedural CT images were reviewed to assess for traversal of UIP findings by needle. Multivariable logistic regression analyses were performed to identify associations between the UIP group and needle traversal with postbiopsy complications, controlling for a range of patient, lesion, and procedural characteristics. RESULTS. The UIP and non-UIP groups included 148 and 4039 patients, respectively; in the UIP group, traversal of UIP findings by needle was observed in 53 patients and not observed in 95 patients. The UIP group, in comparison with the non-UIP group, had a higher frequency of pneumothorax (35.1% vs 17.9%, p < .001) and pneumothorax requiring chest tube placement (6.1% vs 1.5%, p = .001) and lower frequency of hemoptysis (2.0% vs 6.1%, p = .03). In multivariable analyses, the UIP group with traversal of UIP findings by needle, relative to the non-UIP group, showed independent associations with pneumothorax (OR, 5.25; 95% CI, 2.94-9.37; p < .001) and pneumothorax requiring chest tube placement (OR, 9.55; 95% CI, 3.74-24.38; p < .001). The UIP group without traversal of UIP findings by needle, relative to the non-UIP group, was not independently associated with pneumothorax (OR, 1.18; 95% CI, 0.71-1.97; p = .51) or pneumothorax requiring chest tube placement (OR, 1.08; 95% CI, 0.25-4.72; p = .92). The UIP group, with or without traversal of UIP findings by needle, was not independently associated with hemoptysis. No patient experienced air embolism or procedure-related death. CONCLUSION. Needle traversal of UIP findings is a risk factor for pneumothorax and pneumothorax requiring chest tube placement after PTNB. CLINICAL IMPACT. When performing PTNB in patients with UIP, radiologists should plan a needle trajectory that does not traverse UIP findings, when possible.


Asunto(s)
Fibrosis Pulmonar Idiopática , Neoplasias Pulmonares , Neumotórax , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Neumotórax/etiología , Hemoptisis/etiología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Radiografía Intervencional/métodos , Pulmón/diagnóstico por imagen , Pulmón/patología , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Neoplasias Pulmonares/patología , Fibrosis Pulmonar Idiopática/patología , Factores de Riesgo
7.
Clin Nephrol ; 102(2): 73-78, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38699984

RESUMEN

Controversy exists as to the optimal observational time (OT) after outpatient percutaneous kidney biopsy. Further, there is some uncertainty about the benefit of smaller (18-gauge) vs. larger (16-gauge) biopsy needles. At our institution, we have been lowering the OT after outpatient kidney biopsies. Initially in 2015, we were monitoring for 6 hours and gradually began to decrease the OT over time. From 2020, we have adopted an OT of less than 4 hours. During this time period (in 2018), we also began using a smaller gauge needle (18 gauge). We reviewed all outpatient kidney biopsies performed by the nephrology division at our institution since 2015. There were 137 biopsies reviewed. 63 had OT of 4 - 6 hours, and 74 had OT < 4 hours. There was a total of 4 significant complications (2.9%). Two complications, symptomatic retroperitoneal bleeds, were detected in less than 3 hours. The other 2 complications were seen at 9 hours (clot retention) and 72 hours (retroperitoneal bleed after anticoagulation restarted). 63% of the biopsies were done using 18-gauge needles with 1 complication in this group vs. 3 in the 16-gauge group. All cases had adequate tissue for interpretation based on the ability to make a kidney diagnosis. The number of glomeruli obtained in the 18-gauge group was 29 ± 13 glomeruli, and in the 16-gauge group was 25 ± 10, which did not differ between groups. In summary, in an outpatient population, all significant post-biopsy complications were evident either within the first 3 hours or after 9 hours, and this suggests the feasibility of using shorter than standard OT in outpatient kidney biopsies. Furthermore, an 18-gauge needle may lower the risk of complications and obtain adequate tissue.


Asunto(s)
Riñón , Agujas , Humanos , Riñón/patología , Femenino , Masculino , Factores de Tiempo , Persona de Mediana Edad , Estudios Retrospectivos , Biopsia con Aguja/instrumentación , Biopsia con Aguja/métodos , Biopsia con Aguja/efectos adversos , Adulto , Anciano , Diseño de Equipo , Atención Ambulatoria , Enfermedades Renales/patología
8.
Clin Radiol ; 79(4): 263-271, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38220515

RESUMEN

AIM: To investigate the diagnostic performance of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) for thymic epithelial tumours (TETs) and the complication rate after PTNB including seeding after PTNB. MATERIALS AND METHODS: This retrospective study identified PTNBs for anterior mediastinal lesions between May 2007 and September 2021. The diagnostic performance for TETs and complications were investigated. The concordance of the histological grades of TETs between PTNB and surgery was evaluated. The factors associated with pleural seeding after PTNB were determined using Cox regression analysis. RESULTS: Of 387 PTNBs, 235 PTNBs from 225 patients diagnosed as TETs (124 thymomas and 101 thymic carcinomas) and 150 PTNBs from 133 patients diagnosed as other than TETs were included. The sensitivity, specificity, and accuracy for TETs were 89.4% (210/235), 100% (210/210), and 93.5% (360/385), respectively, with an immediate complication rate of 4.4% (17/385). The concordance rate of the histological grades between PTNB and surgery was 73.3% (77/105) after excluding uncategorised types of thymomas. During follow-up after PTNB (median duration, 38.8 months; range, 0.3-164.6 months), no tract seeding was observed. Pleural seeding was observed in 26 patients. Thymic carcinoma (hazard ratio [HR], 5.94; 95% confidence interval [CI], 2.07-17.08; p=0.001) and incomplete resection (HR, 3.29; 95% CI, 1.20-9.02; p=0.02) were associated with pleural seeding, while the biopsy approach type (transpleural versus parasternal) was not associated (p=0.12). CONCLUSIONS: Pretreatment biopsy for TETs was accurate and safe and may be considered for diagnosing TETs, particularly when the diagnosis is challenging and histological diagnosis is mandatory.


Asunto(s)
Neoplasias Glandulares y Epiteliales , Timoma , Neoplasias del Timo , Humanos , Timoma/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Neoplasias del Timo/diagnóstico por imagen , Neoplasias Glandulares y Epiteliales/diagnóstico por imagen
9.
Respiration ; 103(7): 388-396, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38599179

RESUMEN

INTRODUCTION: There is no consensus regarding the most appropriate management of suspected malignant pulmonary ground-glass nodules (GGNs). OBJECTIVE: We aimed to explore the feasibility and safety of synchronous computed tomography-guided percutaneous transthoracic needle biopsy (PTNB) and microwave ablation (MWA) for patients highly suspicious of having malignant GGNs. METHODS: We retrospectively reviewed medical records between July 2020 and April 2023 from our medical center. Eligible patients synchronously underwent PTNB and MWA (either MWA immediately after PTNB [PTNB-first group] or PTNB immediately after MWA [MWA-first group]) at the the physician's discretion. We analyzed the rate of definitive diagnosis and technical success, the length of hospital stay, the postoperative efficacy, and periprocedural complications. RESULTS: Of 65 patients who were enrolled, the rate of definitive diagnosis was 86.2%, which did not differ when stratified by the tumor size, the consolidation-to-tumor ratio, or the sequence of the two procedures (all p > 0.05). The diagnostic rate of malignancy was 83.1%. After the median follow-up duration of 18.5 months, the local control rate was 98.2% and the rate of completed ablation was 48.2%. The rate of perioperative minor and major complications was 44.6% and 6.2%, respectively. The most common adverse events included pain, cough, and mild hemorrhage. Mild hemorrhage took place significantly less frequently in the MWA-first group than in the PTNB-first group (16.7% vs. 45.5%, p < 0.05). CONCLUSION: Synchronous PTNB and MWA are feasible and well tolerated for patients highly suspicious of having malignant GGNs, providing an alternative option for patients who are ineligible for surgical resection.


Asunto(s)
Biopsia Guiada por Imagen , Neoplasias Pulmonares , Microondas , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Estudios Retrospectivos , Microondas/uso terapéutico , Anciano , Biopsia Guiada por Imagen/métodos , Estudios de Factibilidad , Biopsia con Aguja/métodos , Nódulos Pulmonares Múltiples/patología , Nódulos Pulmonares Múltiples/cirugía , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Adulto
10.
Semin Diagn Pathol ; 41(2): 79-87, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38184420

RESUMEN

Autoimmune pancreatitis (AIP) is classified into type 1 (IgG4-related) and type 2 (IgG4-unrelated) and the interpretation of pancreatic biopsy findings plays a crucial role in their diagnosis. Needle biopsy of type 1 AIP in the acute or subacute phase shows a diffuse lymphoplasmacytic infiltrate, storiform fibrosis, obliterative phlebitis, and the infiltration of many IgG4-positive plasma cells. In a later phase, changes become less inflammatory and more fibrotic, making interpretations more challenging. Confirmation of the lack of 'negative' findings that are unlikely to occur in type 1 AIP (e.g., neutrophilic infiltration, abscess) is important to avoid an overdiagnosis. The number of IgG4-positive plasma cells increases to >10 cells/high-power field (hpf), and the IgG4/IgG-positive plasma cell ratio exceeds 40 %. However, these are minimal criteria and typical cases show >30 positive cells/hpf and a ratio >70 % even in biopsy specimens. Therefore, cases with a borderline increase in this number or ratio need to be diagnosed with caution. In cases of ductal adenocarcinoma, the upstream pancreas rarely shows type 1 AIP-like changes; however, the ratio of IgG4/IgG-positive plasma cells is typically <40 %. Although the identification of a granulocytic epithelial lesion (GEL) is crucial for type 2 AIP, this finding needs to be interpreted in conjunction with a background dense lymphoplasmacytic infiltrate. An isolated neutrophilic duct injury can occur in peritumoral or obstructive pancreatitis. Drug-induced pancreatitis in patients with inflammatory bowel disease often mimics type 2 AIP clinically and pathologically. IL-8 and PD-L1 are potential ancillary immunohistochemical markers for type 2 AIP, requiring validation studies.


Asunto(s)
Enfermedades Autoinmunes , Pancreatitis Autoinmune , Pancreatitis , Humanos , Pancreatitis Autoinmune/diagnóstico , Diagnóstico Diferencial , Enfermedades Autoinmunes/diagnóstico , Enfermedades Autoinmunes/patología , Pancreatitis/diagnóstico , Pancreatitis/patología , Biopsia con Aguja , Inmunoglobulina G
11.
BMC Pulm Med ; 24(1): 33, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38218792

RESUMEN

OBJECTIVE: This study aimed to assess the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after percutaneous transthoracic lung biopsy (PTLB) guided by C-arm cone-beam computed tomography (CBCT). Furthermore, this study aimed to examine the relationships between PTX and PH with demographics, clinical characteristics, imaging, and PTLB parameters. METHODS: A retrospective analysis was conducted on 192 patients who underwent PTLB at our hospital between January 2019 and October 2022. Incidences of PTX and PH were recorded. PTX was considered clinically significant if treated with chest tube insertion (CTI), and PH if treated with bronchoscopes or endovascular treatments. The various factors on PTX and PH were analyzed using the Chi-squared test and Student t-test. Logistic regression analyses were then used to determine these factors on the correlation to develop PTX and PH. RESULTS: PTX occurred in 67/192 cases (34.9%); CTI was required in 5/67 (7.5%). PH occurred in 63/192 cases (32.8%) and none of these cases required bronchoscopes or endovascular treatments. Lesion diameter (ORPTX = 0.822; ORPH = 0.785), presence of pulmonary emphysema (ORPH = 2.148), the number of samples (ORPH = 1.834), the use of gelfoam (ORPTX = 0.474; ORPH = 0.341) and ablation (ORPTX = 2.351; ORPH = 3.443) showed statistically significant correlation to PTX and PH. CONCLUSIONS: CBCT-guided PTLB is a safe and effective method for performing lung biopsies. The use of gelfoam has been shown to reduce the occurrence of PTX and PH. However, caution should be exercised when combining radiofrequency ablation with PTLB, as it may increase the risk of PTX and PH.


Asunto(s)
Enfermedades Pulmonares , Neumotórax , Humanos , Neumotórax/epidemiología , Neumotórax/etiología , Neumotórax/patología , Incidencia , Estudios Retrospectivos , Relevancia Clínica , Pulmón/diagnóstico por imagen , Pulmón/patología , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/epidemiología , Enfermedades Pulmonares/complicaciones , Tomografía Computarizada de Haz Cónico , Hemorragia/epidemiología , Hemorragia/etiología , Biopsia con Aguja/efectos adversos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Factores de Riesgo
12.
Can J Urol ; 31(3): 11886-11891, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38912941

RESUMEN

INTRODUCTION: To define the smallest prostate needle biopsy (PNB) template necessary for accurate tissue diagnosis in men with markedly elevated PSA while decreasing procedural morbidity. MATERIALS AND METHODS: We performed a chart review of 80 men presenting with a newly elevated PSA > 100 ng/mL who underwent biopsy (PNB or metastatic site). For patients who underwent a full 12-core biopsy, simulated templates of 2- to 10-cores were generated by randomly drawing subsets of biopsies from their full-template findings. Templates were iterated to randomize core location and generate theoretical smaller template outcomes. Simulated biopsy results were compared to full-template findings to determine accuracy to maximal Grade Group (GG) diagnosis. RESULTS: Amongst those that underwent PNB, 93% had GG 4 or 5 disease. Twenty-two (40%) underwent a full 12-core biopsy, 20 (37%) a 6-core biopsy, and only 8 (15%) had fewer than six biopsy cores sampled at our hospital. Simulated templates with 2-, 4-, 6-, and 8-cores correctly diagnosed prostate cancer in all patients, and accurately identified the maximal GG in 82%, 91%, 95%, and 97% of patients, respectively. The biopsy locations most likely to detect maximal GG were medial mid and base sites bilaterally. A 4-core template of these sites would have accurately detected the maximal GG in 95% of patients relative to a full 12-core template. CONCLUSIONS: In men presenting with PSA > 100 ng/mL, decreasing from a 12-core to a 4-core prostate biopsy template results in universal cancer detection and minimal under-grading while theoretically decreasing procedural morbidity and cost.


Asunto(s)
Antígeno Prostático Específico , Próstata , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Antígeno Prostático Específico/sangre , Anciano , Persona de Mediana Edad , Biopsia con Aguja Gruesa/métodos , Próstata/patología , Estudios Retrospectivos , Clasificación del Tumor , Biopsia con Aguja/métodos
13.
Acta Radiol ; 65(5): 432-440, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38342990

RESUMEN

BACKGROUND: Computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) is not recommended as the diagnostic modality of choice for anterior mediastinal lymphoma, despite its advantages of minimal invasiveness and easy accessibility. PURPOSE: To identify the modifiable risk factors for non-diagnostic results from CT-guided PTNB for anterior mediastinal lymphoma. MATERIAL AND METHODS: This retrospective study identified CT-guided PTNB for anterior mediastinal lesions diagnosed as lymphoma between May 2007 and December 2021. The diagnostic sensitivity and complications were investigated. The appropriateness of PTNB targeting was evaluated using positron emission tomography (PET)/CT and images from intra-procedural CT-guided PTNB. Targeting was considered inappropriate when the supposed trajectory of the cutting needle was within a region of abnormally low metabolism. The risk factors for non-diagnostic results were determined using logistic regression analysis. RESULTS: A total of 67 PTNBs in 60 patients were included. The diagnostic sensitivity for lymphoma was 76.1% (51/67), with an immediate complication rate of 4.5% (3/67). According to the PET/CT images, PTNB targeting was inappropriate in 10/14 (71.4%) of the non-diagnostic PTNBs but appropriate in all diagnostic PTNBs (P <0.001). Inappropriate targeting was the only significant risk factor for non-diagnostic results (odds ratio = 203.69; 95% confidence interval = 8.17-999.99; P = 0.001). The number of specimen acquisitions was not associated with non-diagnostic results (P = 0.40). CONCLUSIONS: Only inappropriate targeting of the non-viable portion according to PET/CT was an independent risk factor for non-diagnostic results. Acquiring PET/CT scans before biopsy and targeting the viable portion on PET/CT may help improve the diagnostic sensitivity of PTNB.


Asunto(s)
Biopsia Guiada por Imagen , Linfoma , Neoplasias del Mediastino , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Masculino , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Neoplasias del Mediastino/diagnóstico por imagen , Neoplasias del Mediastino/patología , Biopsia Guiada por Imagen/métodos , Adulto , Linfoma/diagnóstico por imagen , Linfoma/patología , Anciano , Biopsia con Aguja/métodos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Adulto Joven , Anciano de 80 o más Años , Radiografía Intervencional/métodos , Mediastino/diagnóstico por imagen
14.
Skeletal Radiol ; 53(4): 725-731, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37851081

RESUMEN

OBJECTIVE: To determine the value of CT-guided bone core biopsy and investigate factors that affect diagnostic yield and biopsy outcome. MATERIALS AND METHODS: The single-centre retrospective analysis included 447 patients who had CT-guided core biopsy with a 13-G needle (Bonopty®) from January 2016 to December 2021. Histological results or ≥ 6 months of clinical and radiological follow-up served as outcome references. A successful biopsy was classified as "diagnostic" when a definitive diagnosis was made and "adequate" when only the malignant or benign nature of the tumour could be determined. Biopsies were "nondiagnostic" when the nature of the lesion could not be determined. The occult lesions were defined as not seen on CT but visible on other modalities. RESULTS: In 275 (62%) females and 172 (38%) males, the overall success rate was 85% (383 biopsies), with 314 (70%) diagnostic biopsies and 69 (15%) adequate biopsies. There was no relationship between biopsy success and the localisation of the lesion, length of biopsy material, or number of biopsy attempts. The lesions' nature had a statistically significant effect on biopsy success with lytic and mixed lesions having the highest success rate. Occult lesions had the lowest success rate. CONCLUSION: CT-guided bone core biopsy is an effective method in the workup of musculoskeletal diseases with the highest success rate in lytic and mixed lesions. No apparent relationship was found between biopsy success and biopsy length, number of attempts, or localisation of the lesion.


Asunto(s)
Radiografía Intervencional , Tomografía Computarizada por Rayos X , Masculino , Femenino , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Radiografía Intervencional/métodos , Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/métodos , Biopsia con Aguja Gruesa
15.
Radiol Med ; 129(1): 38-47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37874442

RESUMEN

RATIONALE AND OBJECTIVES: Our multicentric study analysed clinical, radiologic and pathologic features in patients with atypical ductal hyperplasia (ADH) diagnosed with vacuum-assisted biopsy (VAB), to identify factors associated with the risk of upgrade, to develop a scoring system to support decision making. MATERIALS AND METHODS: Patients with ADH on VAB under stereotactic/tomosynthesis guidance (2012-2022) were eligible. Inclusion criteria were availability of surgical histopathological examination of the entire lesion or radiologic follow-up (FUP) ≥ 24 months. VAB results were compared with surgical pathological results or with imaging FUP evolution to assess upgrade. A backward stepwise linear regression was used to identify predictors of upgrade. The discriminatory power of the model was calculated through the area under the receiver operating curve (ROC-AUC); the Hosmer-Lemeshow test was used to assess model calibration. The points system was developed based on the selected risk factors, and the probability of upgrade associated with each point total was determined. RESULTS: 112 ADH lesions were included: 91 (91/112, 81.3%) underwent surgical excision with 20 diagnosis of malignancy, while 21 (21/112, 18.7%) underwent imaging FUP with one interval change (mean FUP time 48 months). Overall upgrade rate was 18.7% (21/112). Age, menopausal status, concurrent breast cancer, BIRADS classification and number of foci of ADH were identified as risk factors for upgrade. Our model showed an AUC = 0.85 (95% CI 0.76-0.94). The points system showed that the risk of upgrade is < 2% when the total score is ≤ 1. CONCLUSION: Our scoring system seemed a promising easy-to-use decision support tool for management of ADH, decreasing unnecessary surgeries, reducing patients' overtreatment and healthcare costs.


Asunto(s)
Neoplasias de la Mama , Carcinoma Intraductal no Infiltrante , Humanos , Femenino , Carcinoma Intraductal no Infiltrante/diagnóstico , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/cirugía , Mama/patología , Neoplasias de la Mama/patología , Biopsia con Aguja , Diagnóstico por Imagen , Estudios Retrospectivos
16.
Int J Mol Sci ; 25(9)2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38731882

RESUMEN

In cholinergic urticaria (CholU), small, itchy wheals are induced by exercise or passive warming and reduced sweating has been reported. Despite the described reduced muscarinic receptor expression, sweat duct obstruction, or sweat allergy, the underlying pathomechanisms are not well understood. To gain further insights, we collected skin biopsies before and after pulse-controlled ergometry and sweat after sauna provocation from CholU patients as well as healthy controls. CholU patients displayed partially severely reduced local sweating, yet total sweat volume was unaltered. However, sweat electrolyte composition was altered, with increased K+ concentration in CholU patients. Formalin-fixed, paraffin-embedded biopsies were stained to explore sweat leakage and tight junction protein expression. Dermcidin staining was not found outside the sweat glands. In the secretory coils of sweat glands, the distribution of claudin-3 and -10b as well as occludin was altered, but the zonula occludens-1 location was unchanged. In all, dermcidin and tight junction protein staining suggests an intact barrier with reduced sweat production capability in CholU patients. For future studies, an ex vivo skin model for quantification of sweat secretion was established, in which sweat secretion could be pharmacologically stimulated or blocked. This ex vivo model will be used to further investigate sweat gland function in CholU patients and decipher the underlying pathomechanism(s).


Asunto(s)
Urticaria Crónica Inducible , Glándulas Sudoríparas , Sudor , Uniones Estrechas , Sudor/química , Uniones Estrechas/metabolismo , Glándulas Sudoríparas/metabolismo , Ergometría , Proteínas de Uniones Estrechas/metabolismo , Urticaria Crónica Inducible/metabolismo , Urticaria Crónica Inducible/patología , Humanos , Masculino , Femenino , Adulto , Receptor Muscarínico M3/metabolismo , Biopsia con Aguja
17.
Zhonghua Yi Xue Za Zhi ; 104(16): 1403-1409, 2024 Apr 23.
Artículo en Zh | MEDLINE | ID: mdl-38644291

RESUMEN

Objective: To investigate the safety and accuracy of CT-guided intracranial puncture biopsy and the possible influencing factors of postoperative bleeding complications. Methods: A case series study. A retrospective analysis was conducted on 101 patients who underwent CT-guided intracranial puncture biopsy at the First Affiliated Hospital of Zhengzhou University from January 2017 to December 2021. The basic data of patients and the safety and accuracy of CT-guided intracranial puncture biopsy were analyzed statistically. Univariate and multivariate logistic regression analysis were used to screen the influencing factors of bleeding complications in CT-guided intracranial puncture biopsy, and the bleeding complications in glioma subgroup were analyzed. Results: Among the 101 patients, 53 were males and 48 were females, aged (53.7±17.2) years. The average diameter of intracranial lesions was (3.5±1.4) cm, while the vertical distance from the lesion to the meninges was (2.4±1.7) cm. The needle's intracranial depth reached (3.2±1.8) cm, with adjustments averaging (3±1) occurrences and an average procedural duration of (40.2±12.9) minutes. Pathological diagnoses included glioma (36 cases), gliosis (3 cases), lymphoma (32 cases), metastatic tumors (7 cases), inflammatory lesions (13 cases), and 10 indeterminate cases. The positive rate of puncture pathology was 90.1% (91/101), and the diagnostic coincidence rate was 94.0% (78/83). The incidence of bleeding complications in CT-guided intracranial puncture biopsy was 26.7% (27/101), of which 23 cases had small intratoma or needle path bleeding, 4 cases had massive bleeding, and 2 cases died. The patients were divided into bleeding group (n=27) and no bleeding group (n=74), according to the presence or absence of bleeding. The results of univariate logistic regression analysis showed that thrombin time≥15 s and the number of needle adjustment were the factors affecting the occurrence of bleeding complications (both P<0.05), and the results of multivariate logistic regression showed that thrombin time≥15 s was the related factor for bleeding. Patients with thrombin time≥15 s had a 3.045 times higher risk of bleeding than those with thrombin time<15 s (OR=3.045,95%CI:1.189-7.799,P=0.020). Among the 101 patients, 36 cases of midbrain glioma were divided into low-grade glioma group (n=11) and high-grade glioma group (n=25) according to the pathological grade. Subgroup analysis showed that the risk of bleeding for high-grade gliomas was 9.231 times higher than that for low-grade gliomas (OR=9.231,95%CI:1.023-83.331,P=0.031). Conclusions: CT-guided intracranial puncture biopsy is safe and feasible with high accuracy. Complication rates are associated with thrombin time≥15 s, especially high-grade glioma, which increases the risk of postoperative bleeding.


Asunto(s)
Neoplasias Encefálicas , Biopsia Guiada por Imagen , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Glioma/patología , Adulto , Anciano , Encéfalo/patología , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos
18.
Forensic Sci Med Pathol ; 20(1): 295-296, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37357244

RESUMEN

To differentiate between medical malpractice and expected, but rare, medical complication in a medicolegal autopsy context is often difficult. Such an assessment requires knowledge about the clinical practice associated with the procedure at hand, and that findings of the autopsy, including medical relevant information such as patient chart, radiological imaging, and statements from witnesses about the medical procedure itself, provides evidence that substantiate either conclusion. In a case report published in the journal such an assessment is discussed by presenting findings and circumstances surrounding the death of a patient during a percutaneous needle lung biopsy procedure. The authors conclude that the death was not due to medical malpractice. However, in this commentary it is highlighted that the reasoning behind the conclusion needs to be further substantiated.


Asunto(s)
Embolia Aérea , Mala Praxis , Humanos , Embolia Aérea/diagnóstico por imagen , Embolia Aérea/etiología , Embolia Aérea/patología , Tomografía Computarizada por Rayos X/efectos adversos , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Pulmón/diagnóstico por imagen , Pulmón/patología
19.
Forensic Sci Med Pathol ; 20(1): 199-204, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37160632

RESUMEN

Computed tomography (CT)-guided percutaneous needle biopsy of the lung is a well-recognized and relatively safe diagnostic procedure for suspicious lung masses. Systemic air embolism (SAE) is a rare complication of transthoracic percutaneous lung biopsies. Herein, we present a case of an 81-year-old man who underwent CT-guided percutaneous needle biopsy of a suspicious nodule in the lower lobe of the right lung. Shortly after the procedure, the patient coughed up blood which prompted repeat CT imaging. He was found to have a massive cardiac air embolism. The patient became unresponsive and, despite resuscitation efforts, was pronounced dead. The pathophysiology, risk factors, clinical features, radiological evidence, and autopsy findings associated with SAE are discussed, which may, in light of the current literature, assist with the dilemma between assessing procedural complications and medical liability. Given the instances of SAE in the setting of long operative procedures despite careful technical execution, providing accurate and in-depth information, including procedure-related risks, even the rarest but potentially fatal ones, is recommended for informed consent to reduce medicolegal litigation issues.


Asunto(s)
Embolia Aérea , Mala Praxis , Masculino , Humanos , Anciano de 80 o más Años , Embolia Aérea/diagnóstico por imagen , Embolia Aérea/etiología , Embolia Aérea/patología , Pulmón/diagnóstico por imagen , Pulmón/patología , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Tomografía Computarizada por Rayos X/efectos adversos , Biopsia Guiada por Imagen/efectos adversos
20.
Minim Invasive Ther Allied Technol ; 33(3): 171-175, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38315057

RESUMEN

INTRODUCTION: The purpose is to clarify the safety and clinical contribution of computed tomography (CT)-guided percutaneous needle-biopsy for patients with cervical spine lesion. MATERIAL AND METHODS: Between June 2015 and August 2022, CT-guided percutaneous needle biopsies were performed for 15 cervical spine lesions of 15 patients (8 male, 7 female; 2-81 years old). The technical success, clinical contribution, and safety were evaluated. Technical success was defined as the completion of the biopsy procedure. Clinical contribution was defined as any contribution to the therapeutic strategy. Safety was assessed by the Common Terminology Criteria for Adverse Events, version 5.0. RESULTS: The technical success rate was 100%. In all 15 patients, nontarget organs (e.g., major vessels, spinal cord) could be avoided. The post-biopsy histological diagnoses were myeloma (n = 2), metastatic adenocarcinoma (n = 2), chordoma (n = 2), Langerhans cell histiocytosis (n = 3), and one case each of malignant lymphoma, schwannoma, pyogenic spondylitis, non-pyogenic spondylitis, degenerative change, and non-pathological fracture. All of these diagnoses contributed to the therapeutic strategy decisions. One case of grade 2 pain was observed, but no complications with grade 3 or more were observed during or after the biopsies. CONCLUSION: CT-guided percutaneous needle biopsies for cervical spine lesions were safe and clinically beneficial.


Asunto(s)
Vértebras Cervicales , Biopsia Guiada por Imagen , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Biopsia Guiada por Imagen/métodos , Biopsia Guiada por Imagen/efectos adversos , Anciano de 80 o más Años , Adulto , Adolescente , Adulto Joven , Niño , Preescolar , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Estudios Retrospectivos , Enfermedades de la Columna Vertebral/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA