Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24.360
Filtrar
Más filtros

Intervalo de año de publicación
1.
Eur Heart J ; 45(1): 32-41, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37453044

RESUMEN

AIMS: Transoesophageal echocardiography (TOE) is often performed before catheter ablation or cardioversion to rule out the presence of left atrial appendage thrombus (LAT) in patients on chronic oral anticoagulation (OAC), despite associated discomfort. A machine learning model [LAT-artificial intelligence (AI)] was developed to predict the presence of LAT based on clinical and transthoracic echocardiography (TTE) features. METHODS AND RESULTS: Data from a 13-site prospective registry of patients who underwent TOE before cardioversion or catheter ablation were used. LAT-AI was trained to predict LAT using data from 12 sites (n = 2827) and tested externally in patients on chronic OAC from two sites (n = 1284). Areas under the receiver operating characteristic curve (AUC) of LAT-AI were compared with that of left ventricular ejection fraction (LVEF) and CHA2DS2-VASc score. A decision threshold allowing for a 99% negative predictive value was defined in the development cohort. A protocol where TOE in patients on chronic OAC is performed depending on the LAT-AI score was validated in the external cohort. In the external testing cohort, LAT was found in 5.5% of patients. LAT-AI achieved an AUC of 0.85 [95% confidence interval (CI): 0.82-0.89], outperforming LVEF (0.81, 95% CI 0.76-0.86, P < .0001) and CHA2DS2-VASc score (0.69, 95% CI: 0.63-0.7, P < .0001) in the entire external cohort. Based on the proposed protocol, 40% of patients on chronic OAC from the external cohort would safely avoid TOE. CONCLUSION: LAT-AI allows accurate prediction of LAT. A LAT-AI-based protocol could be used to guide the decision to perform TOE despite chronic OAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cardiopatías , Trombosis , Humanos , Ecocardiografía Transesofágica/métodos , Apéndice Atrial/diagnóstico por imagen , Volumen Sistólico , Inteligencia Artificial , Fibrilación Atrial/complicaciones , Función Ventricular Izquierda , Ecocardiografía , Cardiopatías/diagnóstico , Trombosis/diagnóstico , Factores de Riesgo
2.
Eur Heart J ; 45(3): 214-229, 2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-38088437

RESUMEN

BACKGROUND AND AIMS: Residual leaks are not infrequent after left atrial appendage occlusion. However, there is still uncertainty regarding their prognostic implications. The aim of this study is to evaluate the impact of residual leaks after left atrial appendage occlusion. METHODS: A literature search was conducted until 19 February 2023. Residual leaks comprised peri-device leaks (PDLs) on transoesophageal echocardiography (TEE) or computed tomography (CT), as well as left atrial appendage patency on CT. Random-effects meta-analyses were performed to assess the clinical impact of residual leaks. RESULTS: Overall 48 eligible studies (44 non-randomized/observational and 4 randomized studies) including 61 666 patients with atrial fibrillation who underwent left atrial appendage occlusion were analysed. Peri-device leak by TEE was present in 26.1% of patients. Computed tomography-based left atrial appendage patency and PDL were present in 54.9% and 57.3% of patients, respectively. Transoesophageal echocardiography-based PDL (i.e. any reported PDL regardless of its size) was significantly associated with a higher risk of thromboembolism [pooled odds ratio (pOR) 2.04, 95% confidence interval (CI): 1.52-2.74], all-cause mortality (pOR 1.16, 95% CI: 1.08-1.24), and major bleeding (pOR 1.12, 95% CI: 1.03-1.22), compared with no reported PDL. A positive graded association between PDL size and risk of thromboembolism was noted across TEE cut-offs. For any PDL of >0, >1, >3, and >5 mm, the pORs for thromboembolism were 1.82 (95% CI: 1.35-2.47), 2.13 (95% CI: 1.04-4.35), 4.14 (95% CI: 2.07-8.27), and 4.44 (95% CI: 2.09-9.43), respectively, compared with either no PDL or PDL smaller than each cut-off. Neither left atrial appendage patency, nor PDL by CT was associated with thromboembolism (pOR 1.45 and 1.04, 95% CI: 0.84-2.50 and 0.52-2.07, respectively). CONCLUSIONS: Peri-device leak detected by TEE was associated with adverse events, primarily thromboembolism. Residual leaks detected by CT were more frequent but lacked prognostic significance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Tromboembolia , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Tromboembolia/complicaciones , Ecocardiografía Transesofágica/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía
3.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37927196

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 35(3): 389-398, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38192059

RESUMEN

INTRODUCTION: This study was performed to explore the diagnostic value of cardiac computed tomography angiography (CCTA) for endothelial insufficiency (EIS) of a left atrial appendage (LAA) disc-like occluder. METHODS: Fifty-nine patients with nonvalvular atrial fibrillation who underwent placement of an LAA disc-like occluder (LAmbre; Lifetech Scientific) in our hospital were retrospectively analyzed. Patients who were found to have contrast agent entering the LAA at the 3-month postoperative CCTA examination underwent Hounsfield unit (HU) measurement of the LAA and construction of a three-dimensional (3D) model of the device for preliminary discernment between peri-device leakage (PDL) and EIS. These patients were then further examined by transesophageal echocardiography (TEE) to check for concordance with the computed tomography (CT) findings. According to the CT and TEE results, all patients were divided into the PDL group, total endothelialization group, and EIS group. The endothelial conditions and other implantation-related results were also tracked at the 6-month follow-up. RESULTS: All 59 patients underwent successful implantation of the LAmbre LAA closure device with no severe adverse events during the procedure. Thirty-five patients were found to have contrast agent entering the LAA at the 3-month postoperative CCTA follow-up. Based on the CT HU measurement and the 3D construction analysis results, these 35 patients were divided into the PDL group (19 patients) and the EIS group (16 patients). In the PDL group, the contrast agent infiltrated from the shoulder along the periphery of the occluder on two-dimensional (2D) CT images, and the 3D model showed a gap between the LAA and the device cover. However, the CCTA images of the other 16 patients in the EIS group showed that the contrast agent in the occluder on the 2D CTA images and 3D construction model confirmed the absence of a gap between the LAA and the device cover. TEE confirmed all of the CT results. The 6-month follow-up results showed that 14 of 19 patients in the EIS group achieved total endothelialization, whereas this number in the PDL group was only five of 19 patients. CONCLUSION: CCTA can replace TEE for examination of the endothelialization status, and patients with EIS have a higher chance of endothelialization than patients with PDL.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Angiografía por Tomografía Computarizada/métodos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Retrospectivos , Medios de Contraste , Tomografía Computarizada por Rayos X , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ecocardiografía Transesofágica/métodos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento
5.
Eur J Clin Invest ; 54(2): e14103, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37815038

RESUMEN

BACKGROUND: Despite the availability of current antibiotic and surgical treatment options, infective endocarditis (IE) remains associated with a high mortality rate. Even though two-dimensional (2D) transesophageal echocardiography (TOE) is a major criteria in the diagnosis of IE, it is constrained by the single-plane orientation. Since three-dimensional (3D) TOE provides a comprehensive understanding of the cardiac architecture by allowing for a realistic visualization of the underlying structures in 3D space, it has attracted considerable interest in recent years. AIM: The purpose of this narrative review is to discuss the advantages and pitfalls of 3D TOE in patients with IE, as well as to address emerging photo-realistic 3D techniques that have the potential to enhance the visualization of cardiac structures in this setting. RESULTS: According to recent research, 3D TOE acquisitions outperform 2D acquisitions in terms of vegetation identification accuracy and embolism risk assessment. By reporting a variety of findings that are missed with 2D TOE, but which are validated by surgical examination, 3D TOE further improves the ability to identify endocarditis complications on both native and prosthetic valves. In addition to conventional 3D TOE, future developments in 3D technology led to the development of transillumination and tissue-transparency rendering, which may improve anatomical understanding and depth perception. Due to the use of both conventional and novel 3D techniques, there are more patients who require surgical intervention, indicating that 3D TOE may have a clinical relevance on the surgical management. CONCLUSION: 3D TOE might fill the gaps left by 2D TOE in the diagnosis of IE.


Asunto(s)
Ecocardiografía Tridimensional , Endocarditis , Humanos , Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos , Endocarditis/diagnóstico por imagen , Endocarditis/complicaciones , Ecocardiografía Tridimensional/métodos , Medición de Riesgo
6.
Catheter Cardiovasc Interv ; 103(1): 119-128, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37681962

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) has been considered an alternative treatment to prevent embolic stroke in patients with nonvalvular atrial fibrillation (NVAF). However, it carries a risk of general anesthesia or esophageal injury if guided by transesophageal echocardiography (TEE). AIMS: We aimed to investigate the feasibility and safety of minimal LAAO (MLAAO) using Watchman under fluoroscopy guidance alone in patients with NVAF. METHODS: A total of 249 consecutive patients with NVAF who underwent LAAO using the WATCHMAN device were divided into two groups: the Standard LAAO (SLAAO) group and the MLAAO group. Procedural characteristics and follow-up results were compared between the two groups. RESULTS: There was no statistically significant difference in the rate of successful device implantation (p > 0.05). Fluoroscopy time, radiation exposure dose, and contrast medium usage in the MLAAO group were higher than those in the SLAAO group (p < 0.001). The procedure time and hospitalization duration were significantly lower in the MLAAO group than those in the SLAAO group (p < 0.001). The occluder compression ratio, measured with fluoroscopy, was lower than that measured with TEE (17.63 ± 3.75% vs. 21.69 ± 4.26%, p < 0.001). Significant differences were observed between the SLAAO group and the MLAAO group (p < 0.05) in terms of oropharyngeal/esophageal injury, hypotension, and dysphagia. At 3 months after LAAO, the MLAAO group had a higher incidence of residual flow within 1-5 mm compared to the SLAAO group, although the difference was not statistically significant. CONCLUSION: MLAAO guided by fluoroscopy, instead of TEE, without general anesthesia simplifies the operational process and may be considered safe, effective, and feasible, especially for individuals who are unable to tolerate or unwilling to undergo TEE or general anesthesia.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Cateterismo Cardíaco , Ecocardiografía Transesofágica/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Fluoroscopía
7.
Catheter Cardiovasc Interv ; 103(1): 226-229, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37870093

RESUMEN

Peri-device leak after left atrial appendage closure (LAAC) is often treated with endovascular coils, plugs, or second occluders. This is the first study reporting the Amulet device used for peri-device leak. An 80-year-old male with paroxysmal atrial fibrillation and recurrent falls with head trauma who underwent LAAC with a 24 mm Watchman 2.5 device 3 years ago at another institution was referred to our clinic for management of the peri-device leak. Transesophageal echocardiogram showed persistent residual peri-device leak with 5 mm width along the Coumadin ridge aspect of the device. Computed tomography (CT) also showed the peri-device leak with width of 6 mm and complete opacification of left atrial appendage (LAA). Importantly, CT demonstrated that the Watchman 2.5 device was deployed at distal LAA, leaving the proximal part of LAA with length of 10 mm from ostium. Under general anesthesia, a 22 mm Amulet device was deployed successfully with complete sealing of LAA. Procedure planning is the key to minimize the risk of peri-device leak or device-related thrombosis. Careful assessment of LAA anatomy using multimodality images for peri-device leak after LAAC helped optimal treatment strategy including second LAAC with different type of devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Masculino , Humanos , Anciano de 80 o más Años , Cierre del Apéndice Auricular Izquierdo , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Warfarina , Ecocardiografía Transesofágica , Apéndice Atrial/diagnóstico por imagen
8.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451154

RESUMEN

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Humanos , Ecocardiografía Transesofágica , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia
9.
Catheter Cardiovasc Interv ; 103(1): 234-237, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37890002

RESUMEN

Transcatheter mitral valve-in-valve (ViV) has emerged as a safe and effective therapeutic option for patients with a degenerated mitral bioprosthesis. As procedural techniques mature and operator experience improve, there is a push to adopt a "minimalist" approach of using conscious sedation instead of general anesthesia for faster recovery. The heavy reliance on fluoroscopy for ViV deployment makes feasible the use of intracardiac echocardiography (ICE) instead of transesophageal echocardiography for other procedural imaging requirements. We hereby use a case example to illustrate a step-by-step approach of using four-dimensional ICE to guide transcatheter mitral ViV under conscious sedation.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Falla de Prótesis
10.
Catheter Cardiovasc Interv ; 103(1): 129-136, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37786977

RESUMEN

BACKGROUND: While studies have shown the advantages of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) in left atrial appendage closure (LAAC) preprocedural planning for WATCHMAN™ legacy and FLX devices, there has been no reported long-term data for this approach. OBJECTIVES: We sought to evaluate long-term outcomes using CTA-based preprocedural planning for LAAC using the WATCHMAN™ device. METHODS: A prospective analysis of 231 consecutive patients who underwent LAAC in a single, large academic hospital in the United States was conducted over a 5-year period. CTA-guided preprocedural planning was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. Rates of death, cerebral embolism, systemic embolism, and major and minor bleeding were recorded. Adjusted predicted stroke and major bleeding rates were derived from CHA2DS2-Vasc and HAS-BLED scores, respectively. RESULTS: From January 26, 2017, to November 23, 2021, 231 patients underwent LAAC with CTA preprocedural planning by two operating physicians. The mean age of patients was 76.5 ± 8.4. 59.7% of patients were male. Mean CHA2DS2VASc and HAS-BLED scores were 4.5 ± 1.4 and 3.9 ± 0.9, respectively. All procedures were performed with intracardiac echo (100%). The procedural success rate was 99.1%. The CTA sizing strategy accurately predicted the implant size in 93.5% of patients. Mean number of devices used was 1.10 ± 0.3. Peri-procedural complication rate was 2.2%. 6 patients were lost to follow-up. Mean follow-up was 608.94 days with a total of 377.04 patient years. Median follow-up period of 368 days (interquartile range: 209-1067 days). There were 51 deaths from all causes (13.52 per 100 patient-years), 10 cases of cerebral embolism (2.65 per 100 patient-years), 2 cases of systemic embolism (0.53 per 100 patient-years), 17 cases of major bleeding (4.50 per 100 patient-years), and 31 cases of minor bleeding (8.2 per 100 patient-years). All-cause mortality at 1, 2, and 3 years was 12.7%, 20.9%, and 29.2%, respectively. CV event rates at 1, 2, and 3 years were 2.1%, 6.6%, and 10.5%, respectively. CONCLUSIONS: CTA-based preprocedural planning is accurate in predicting device size for LAAC and associated with excellent clinical outcomes at 5 years.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Embolia Intracraneal , Accidente Cerebrovascular , Humanos , Masculino , Femenino , Estudios de Seguimiento , Cierre del Apéndice Auricular Izquierdo , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Angiografía por Tomografía Computarizada , Resultado del Tratamiento , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Apéndice Atrial/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Hemorragia , Ecocardiografía Transesofágica/efectos adversos
11.
Catheter Cardiovasc Interv ; 103(7): 1148-1151, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38639161

RESUMEN

The transcatheter edge-to-edge mitral valve repair (TEER) has been recommended as a reliable treatment option for selected patients with severe degenerative and functional mitral regurgitation (MR). Although MR patients with rheumatic etiology were excluded from two significant trials (EVEREST II and COAPT) that established a role for the TEER in degenerative and functional MR. However, it has been reported that the TEER procedure could be safely and effectively performed in carefully selected rheumatic MR patients. Therefore, we share a case report of successfully treating severe rheumatic MR using a novel-designed TEER system (JensClipTM).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Cardiopatía Reumática , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/etiología , Cateterismo Cardíaco/instrumentación , Resultado del Tratamiento , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/cirugía , Cardiopatía Reumática/fisiopatología , Cardiopatía Reumática/terapia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Femenino , Ecocardiografía Transesofágica , Ecocardiografía Doppler en Color , Diseño de Prótesis , Prótesis Valvulares Cardíacas , Persona de Mediana Edad , Masculino
12.
Catheter Cardiovasc Interv ; 103(7): 1152-1155, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38606476

RESUMEN

The use of left atrial appendage occlusion (LAAO) devices have gained prominence as an alternative to long-term anticoagulation therapy in patients with atrial fibrillation at risk of stroke and high risk of bleeding. While these devices have shown efficacy in reducing stroke risk, there have been reported cases of embolization of the Watchman device. There are very few cases of successful percutaneous retrieval of embolized Watchman devices from the left ventricle (LV), as many of these cases require open heart surgery for safe removal. We are presenting a case of an 80-year-old male whose Watchman device embolized to the LV and was entrapped on the LV papillary muscle that was then successfully retrieved via percutaneous methods, which shows the percutaneous options remain a viable strategy to retrieve LAAO devices from the LV.


Asunto(s)
Fibrilación Atrial , Cateterismo Cardíaco , Remoción de Dispositivos , Migración de Cuerpo Extraño , Músculos Papilares , Humanos , Masculino , Anciano de 80 o más Años , Resultado del Tratamiento , Fibrilación Atrial/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Migración de Cuerpo Extraño/terapia , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/diagnóstico por imagen , Músculos Papilares/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Embolia/etiología , Embolia/diagnóstico por imagen , Embolia/terapia , Embolia/diagnóstico , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Ecocardiografía Transesofágica
13.
Circ Res ; 130(4): 455-473, 2022 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-35175844

RESUMEN

As populations age worldwide, the burden of valvular heart disease has grown exponentially, and so has the proportion of affected women. Although rheumatic valve disease is declining in high-income countries, degenerative age-related causes are rising. Calcific aortic stenosis and degenerative mitral regurgitation affect a significant proportion of elderly women, particularly those with comorbidities. Women with valvular heart disease have been underrepresented in many of the landmark studies which form the basis for guideline recommendations. As a consequence, surgical referrals in women have often been delayed, with worse postoperative outcomes compared with men. As described in this review, a more recent effort to include women in research studies and clinical trials has increased our knowledge about sex-based differences in epidemiology, pathophysiology, diagnostic criteria, treatment options, outcomes, and prognosis.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/terapia , Complicaciones Cardiovasculares del Embarazo/diagnóstico por imagen , Complicaciones Cardiovasculares del Embarazo/terapia , Caracteres Sexuales , Ecocardiografía Transesofágica/métodos , Femenino , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Embarazo , Complicaciones Cardiovasculares del Embarazo/fisiopatología
14.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38691672

RESUMEN

AIMS: Blood stasis is crucial in developing left atrial (LA) thrombi. LA appendage peak flow velocity (LAAFV) is a quantitative parameter for estimating thromboembolic risk. However, its impact on LA thrombus resolution and clinical outcomes remains unclear. METHODS AND RESULTS: The LAT study was a multicentre observational study investigating patients with atrial fibrillation (AF) and silent LA thrombi detected by transoesophageal echocardiography (TEE). Among 17 436 TEE procedures for patients with AF, 297 patients (1.7%) had silent LA thrombi. Excluding patients without follow-up examinations, we enrolled 169 whose baseline LAAFV was available. Oral anticoagulation use increased from 85.7% at baseline to 97.0% at the final follow-up (P < 0.001). During 1 year, LA thrombus resolution was confirmed in 130 (76.9%) patients within 76 (34-138) days. Conversely, 26 had residual LA thrombi, 8 had thromboembolisms, and 5 required surgical removal. These patients with failed thrombus resolution had lower baseline LAAFV than those with successful resolution (18.0 [15.8-22.0] vs. 22.2 [17.0-35.0], P = 0.003). Despite limited predictive power (area under the curve, 0.659; P = 0.001), LAAFV ≤ 20.0 cm/s (best cut-off) significantly predicted failed LA thrombus resolution, even after adjusting for potential confounders (odds ratio, 2.72; 95% confidence interval, 1.22-6.09; P = 0.015). The incidence of adverse outcomes including ischaemic stroke/systemic embolism, major bleeding, or all-cause death was significantly higher in patients with reduced LAAFV than in those with preserved LAAFV (28.4% vs. 11.6%, log-rank P = 0.005). CONCLUSION: Failed LA thrombus resolution was not rare in patients with AF and silent LA thrombi. Reduced LAAFV was associated with failed LA thrombus resolution and adverse clinical outcomes.


Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Transesofágica , Trombosis , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Masculino , Femenino , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Anciano , Trombosis/fisiopatología , Trombosis/diagnóstico por imagen , Trombosis/complicaciones , Persona de Mediana Edad , Velocidad del Flujo Sanguíneo , Anticoagulantes/uso terapéutico , Factores de Riesgo , Resultado del Tratamiento , Enfermedades Asintomáticas , Factores de Tiempo , Cardiopatías/fisiopatología , Cardiopatías/complicaciones , Cardiopatías/diagnóstico por imagen , Tromboembolia/etiología , Tromboembolia/fisiopatología , Anciano de 80 o más Años , Función del Atrio Izquierdo
15.
Transpl Infect Dis ; 26(3): e14302, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38761053

RESUMEN

BACKGROUND: Infective endocarditis (IE) is a serious complication of bloodstream infections (BSIs) that occurs at variable rates depending on the pathogen and clinical setting. There is a paucity of data describing the risk of IE in patients with hematologic malignancy who develop bacteremia while neutropenic. METHODS: Adult patients on the hematology ward from January 2018 to December 2020 with hematologic malignancy and bacteremia were evaluated retrospectively for endocarditis by applying the 2023 Duke-ISCVID criteria. Charts of possible cases were evaluated 90 days after the initial BSI for new infectious complications that could indicate missed IE. Descriptive statistics compared patients admitted for hematopoietic stem cell transplantation (HSCT) to those admitted for alternative reasons (non-HSCT). RESULTS: Among the 1005 positive blood cultures initially identified, there were 66 episodes in 65 patients with hematologic malignancy and at least grade 3 neutropenia for a mean duration of 11.4 days during their admission. Transthoracic echocardiography (TTE) was performed in 34.8% of BSIs, and transesophageal echocardiography (TEE) in 6.1%. There were no new infectious complications in possible cases 90 days after their initial BSI. No cases of endocarditis were identified. CONCLUSIONS: Endocarditis is rare amongst patients with hematologic malignancy, bacteremia, and neutropenia, and no cases were identified in this cohort. The use of routine TTE in this setting seems unwarranted, and the addition of TEE is unlikely to improve patient-centered outcomes.


Asunto(s)
Bacteriemia , Neoplasias Hematológicas , Trasplante de Células Madre Hematopoyéticas , Neutropenia , Humanos , Neutropenia/complicaciones , Masculino , Femenino , Persona de Mediana Edad , Neoplasias Hematológicas/complicaciones , Estudios Retrospectivos , Bacteriemia/microbiología , Bacteriemia/complicaciones , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Adulto , Endocarditis/microbiología , Endocarditis/complicaciones , Anciano , Ecocardiografía , Ecocardiografía Transesofágica
16.
BMC Cardiovasc Disord ; 24(1): 130, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38424513

RESUMEN

INTRODUCTION: We described a rare case of an adolescent girl with paroxysmal atrial fibrillation originating from the right atrial appendage diverticulum and successfully converted to sinus rhythm after surgical intervention. METHODS: A 19-year-old girl was referred to the hospital for a catheter ablation of paroxysmal atrial fibrillation. conventional radiofrequency ablation using 3-D mapping were ineffective. Activation mapping showed the root of the free wall atrial appendage was first excited and catheter modeling (3D Carto map) showed a sac-like structure. RESULTS: We did selective angiography and further Computed tomography angiography (CTA) and Transesophageal echocardiography (TEE) which showed diverticulum originating from the right atrial appendage. Hence the patient was referred to cardiac surgery and had no recurrent atrial fibrillation at three months postoperative follow up. CONCLUSIONS: Right atrial appendage diverticulum was an extremely rare malformation that can coexist with atrial tachyarrhythmia. Surgical ligation or excision of the abnormal structure with local ablation can achieve excellent results.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Adulto Joven , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter/métodos , Ecocardiografía Transesofágica/métodos , Atrios Cardíacos , Taquicardia , Resultado del Tratamiento
18.
BMC Cardiovasc Disord ; 24(1): 51, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38221637

RESUMEN

Mitral valve aneurysm (MVA) is characterized by a saccular outpouching of the mitral leaflet, and it represents a rare condition typically associated with aortic valve endocarditis. Three-Dimensional Transesophageal Echocardiography (3D-TEE) serves as an effective tool for detecting the presence of MVA and its potential complications. In this report, we present a case involving a young man with striking images of bicuspid aortic valve endocarditis complicated by an aortic root abscess and multiple perforated mitral valve aneurysms, diagnosed using 3D TEE. This case suggests the uncommon coexistence of Marfan like morphotype, bicuspid aortic valve, and infective endocarditis as a triple mechanism in the occurrence of MVA. It underscores the significance of early and accurate imaging diagnosis for facilitating prompt surgical intervention.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Ecocardiografía Tridimensional , Endocarditis Bacteriana , Endocarditis , Aneurisma Cardíaco , Síndrome de Marfan , Humanos , Masculino , Absceso/diagnóstico por imagen , Absceso/etiología , Aorta Torácica , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Ecocardiografía Transesofágica/métodos , Endocarditis/complicaciones , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/cirugía , Aneurisma Cardíaco/etiología , Aneurisma Cardíaco/complicaciones , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía
19.
Anesth Analg ; 138(1): 123-133, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38100804

RESUMEN

BACKGROUND: Guidelines for the evaluation and grading of diastolic dysfunction are available for transthoracic echocardiography (TTE). Transesophageal echocardiography (TEE) is used for this purpose intraoperatively but the level of agreement between these 2 imaging modalities for grading diastolic dysfunction is unknown. We assessed agreement between awake preoperative TTE and intraoperative TEE for grading diastolic dysfunction. METHODS: In 98 patients undergoing cardiac surgery, key Doppler measurements were obtained using TTE and TEE at the following time points: TTE before anesthesia induction (TTEawake), TTE following anesthesia induction (TTEanesth), and TEE following anesthesia induction (TEEanesth). The primary endpoint was grade of diastolic dysfunction categorized by a simplified algorithm, and measured by TTEawake and TEEanesth, for which the weighted κ statistic assessed observed agreement beyond chance. Secondary endpoints were peak early diastolic lateral mitral annular tissue velocity (e'lat) and the ratio of peak early diastolic mitral inflow velocity (E) to e'lat (E/e'lat), measured by TTEawake and TEEanesth, were compared using Bland-Altman limits of agreement. RESULTS: Disagreement in grading diastolic dysfunction by ≥1 grade occurred in 43 (54%) of 79 patients and by ≥2 grades in 8 (10%) patients with paired measurements for analysis, yielding a weighted κ of 0.35 (95% confidence interval [CI], 0.19-0.51) for the observed level of agreement beyond chance. Bland-Altman analysis of paired data for e'lat and E/e'lat demonstrated a mean difference (95% CI) of 0.51 (-0.06 to 1.09) and 0.70 (0.07-1.34), respectively, for measurements made by TTEawake compared to TEEanesth. The percentage (95% CI) of paired measurements for e'lat and E/e'lat that lay outside the [-2, +2] study-specified boundary of acceptable agreement was 36% (27%-48%) and 39% (29%-51%), respectively. Results were generally robust to sensitivity analyses, including comparing measurements between TTEawake and TTEanesth, between TTEanesth and TEEanesth, and after regrading diastolic dysfunction by the American Society of Echocardiography (ASE)/European Association of CardioVascular Imaging (EACVI) algorithm. CONCLUSIONS: There was poor agreement between TTEawake and TEEanesth for grading diastolic dysfunction by a simplified algorithm, with disagreement by ≥1 grade in 54% and by ≥2 grades in 10% of the evaluable cohort. Future studies, including comparing the prognostic utility of TTEawake and TEEanesth for clinically important adverse outcomes that may be a consequence of diastolic dysfunction, are needed to understand whether this disagreement reflects random variability in Doppler variables, misclassification by the changed technique and physiological conditions of intraoperative TEE, or the accurate detection of a clinically relevant change in diastolic dysfunction.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Transesofágica , Humanos , Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos , Algoritmos
20.
Int J Med Sci ; 21(3): 431-438, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38250605

RESUMEN

This prospective observational study investigated the optimal insertion depth of the central venous catheter through the right internal jugular vein using transesophageal echocardiography. After tracheal intubation, the anesthesiologist inserted a probe for esophageal echocardiography into the patient's esophagus. The investigators placed the catheter tip 2 cm above the superior edge of the crista terminalis with echocardiography, which was defined as the optimal point. We measured the inserted length of the catheter. Pearson correlation tests were performed with the measured optimal depth and some patient parameters. We made a new formula for placing the catheter at the optimal position. A total of 89 subjects were enrolled in this trial. The correlation coefficient between the measured optimal depth and the patient's parameters was the highest for patient height (0.703, p < 0.001). We made a new formula of 'height (cm)/10 - 1.5 cm'. The accuracy rate of this formula for the optimal zone was 71.9% (95% confidence interval; 62.4 - 81.4%), which was the highest among the previous formulas or guidelines when we compared. In conclusion, the central venous catheter tip was evaluated with transesophageal echocardiography, and we could make a new formula of 'height (cm)/10 - 1.5', which seemed to be better than other previous guidelines.


Asunto(s)
Catéteres Venosos Centrales , Humanos , Ecocardiografía , Ecocardiografía Transesofágica , Atrios Cardíacos , Venas Yugulares/diagnóstico por imagen , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA