Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 510
Filtrar
Más filtros

Intervalo de año de publicación
1.
Clin Oral Investig ; 28(5): 298, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702521

RESUMEN

OBJECTIVES: To assess the long-term clinical performance of ceramic in-/onlays (CIOs) and cast gold partial crowns (CGPCs) in posterior teeth in terms of success, survival, complications (biological, technical) and quality. MATERIAL AND METHODS: In a retrospective study, a total of 325 patients were recorded after up to 24.8 years (mean 13.9 ± 3.8 years) having (pre-)molars restored with CIO (Empress I, Ivoclar Vivadent, n = 161) and CGPC (Degunorm, DeguDent, n = 164) by supervised undergraduate students. A total of 296 restorations were assessed clinically and radiologically in healthy and endodontically treated teeth using modified United States Public Health Service (USPHS) criteria. Cumulative success and survival rates of the restorations were calculated using Kaplan-Meier estimates. Biological and technical complications were recorded. Status of oral health comprising caries risk and localized periodontitis were assessed. RESULTS: The cumulative success rates of CIOs were 92.1% and of CGPCs 84.2% after mean service times of 14.5 years. The annual failure rates of total service times were 0.5% in teeth restored with CIO (n = 155) and 0.7% in teeth restored with CGPC (n = 163). The cumulative survival rates of CIOs were 93.9% after a mean service time of 15.2 years and decreased to 91.7% after 23.5 years. The cumulative survival rates of CGPCs were 92.6% after a mean service time of 14.9 years and 91.8% after 23.5 years. Complications in CIOs (n = 149) were ceramic fracture (6.7%), secondary caries (4.7%), endodontic complication (2.7%) and tooth fracture (1.3%) compared to CGPCs (n = 147) with endodontic complication (8.8%), secondary caries (4.8%) and decementation (2.0%). Endodontically treated teeth restored with CIO or CGPC revealed significantly less often success compared with corresponding vital teeth (p = .02). CIOs and CGPCs revealed clinically and radiographically good and excellent qualities with 71.8% (107/149) and 68% (100/147) without any significant differences regarding type of restoration. CONCLUSIONS: Both CIOs and CGPCs achieved high survival rates up to 24.8 years when performed by supervised undergraduate students. The longevity of the restorations may benefit from the intraoral repair of accessible defects and, in case of pulp infection or necrosis, an adequate endodontic management. CLINICAL RELEVANCE: CIOs and CGPCs made by supervised undergraduate students are proper restoration types in posterior teeth in the long-term. An adequate preparation design, meticulous care in the inserting technique and constant biofilm removal due to proper oral hygiene combined with professional maintenance care are substantial. The clinical long-term performance was mostly limited by ceramic fractures in CIOs and endodontic complications in CGPCs.


Asunto(s)
Coronas , Fracaso de la Restauración Dental , Humanos , Estudios Retrospectivos , Femenino , Masculino , Adulto , Incrustaciones , Cerámica , Aleaciones de Oro , Caries Dental/terapia , Porcelana Dental/química , Persona de Mediana Edad , Diseño de Prótesis Dental , Diente no Vital , Resultado del Tratamiento
2.
J Prosthet Dent ; 131(6): 1150-1158, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38670907

RESUMEN

STATEMENT OF PROBLEM: More data are needed on the influence of preparation design on the fracture strength, failure type, repairability, and polymerization-induced cracks of molar teeth restored with direct composite resin restorations. PURPOSE: This in vitro and finite element analysis study investigated the effect of different preparation designs on fracture strength, failure type, repairability, tooth deformation, and the formation of polymerization-induced cracks of compromised molars restored with direct composite resin restorations. MATERIAL AND METHODS: Human molars (n=64) were randomly assigned to 4 different preparation designs: undermined inlay (UI), extended inlay (EI), restricted overlay (RO), and extended overlay (EO). The teeth were restored using direct composite resin and subjected to artificial thermomechanical aging in a mastication simulator, followed by load-to-failure testing. Three-dimensional (3D) finite element analysis was conducted to assess tooth deformation. Polymerization-induced cracks were evaluated using optical microscopy and transillumination. The fracture strength data were analyzed using a Kruskal-Wallis test, while the failure mode, repairability, and polymerization cracks were analyzed using the Fisher exact test (α=.05). RESULTS: All specimens withstood thermomechanical aging, and no statistically significant difference in fracture strength was observed among the 4 preparation designs (P>.05). The finite element analysis showed differences in tooth deformation, but no correlation was observed with in vitro fracture resistance. The RO and EO groups presented significantly more destructive failures compared with the UI and EI groups (P<.01). The RO group had significantly fewer repairable failures than the UI and EI groups (P=.024). A correlation was found between higher frequencies of repairability and higher tooth deformation. A significant correlation between the increase in microfractures and preparation design was observed (P<.01), with the UI group exhibiting a higher increase in microfracture size compared with the EO group (P<.05). CONCLUSIONS: No influence of preparation design on the fracture strength of compromised molars restored with direct composite resin restorations was evident in this study, but the failure mode of cusp coverage restorations was more destructive and often less repairable. The finite element analysis showed more tooth deformation in inlay preparations, with lower stresses within the root, leading to more reparable fractures. Since cusp coverage direct composite resin restorations fractured in a more destructive manner, this study suggests that even a tooth with undermined cusps should be restored without cusp coverage.


Asunto(s)
Resinas Compuestas , Fracaso de la Restauración Dental , Restauración Dental Permanente , Análisis del Estrés Dental , Análisis de Elementos Finitos , Diente Molar , Fracturas de los Dientes , Resinas Compuestas/uso terapéutico , Resinas Compuestas/química , Humanos , Restauración Dental Permanente/métodos , Fracturas de los Dientes/prevención & control , Fracturas de los Dientes/fisiopatología , Técnicas In Vitro , Incrustaciones , Ensayo de Materiales , Polimerizacion
3.
BMC Oral Health ; 24(1): 101, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38233771

RESUMEN

TRIAL DESIGN: This is a randomized, controlled, superiority, double-blinded, parallel-group, two-arms trial with an allocation ratio of 1:1. The aim of this trial was to compare the two-year clinical performance of partial indirect restorations fabricated from CAD/CAM nano-hybrid composite and ceramic lithium disilicate blocks using the modified USPHS criteria. METHODS: In two parallel groups (n = 50 restorations), fifty participants having mutilated vital teeth with a minimum of two remaining walls were randomly enrolled in this trial and received indirect restorations of either nano-hybrid composite resin blocks (Brilliant, Coltene, Switzerland) or Lithium Disilicate (IPS Emax CAD). The restorations were assessed using modified USPHS criteria by two independent blinded assessors at baseline, six months, one-year and two years follow-up visits. Categorical and ordinal data were presented as frequencies and percentages. Categorical data were analyzed using the chi-square test. Ordinal data were analyzed using the Mann-Whitney U test for intergroup comparisons and Freidman's test followed by the Nemenyi post hoc test for intragroup comparisons. Numerical data were presented as mean and standard deviation values. They were analyzed for normality using the Shapiro-Wilk test. Data were found to be normally distributed and were analyzed using the independent t-test. The significance level was set at p ≤ 0.05 within all tests. RESULTS: Forty-eight participants received the allocated intervention and completed the follow-up periods. There was a statistically significant difference between both tested materials for all USPHS criteria regarding Marginal integrity and Marginal discoloration at six-months Follow-up, but with no statistically significant difference at one- and two-year follow-up. CONCLUSIONS: Both materials showed an acceptable, successful clinical performance along the two-years follow-up period. CLINICAL RELEVANCE: The CAD/CAM nano-hybrid composite blocks are as reliable as Lithium disilicate for restoring mutilated vital teeth.


Asunto(s)
Porcelana Dental , Incrustaciones , Humanos , Cerámica , Diseño Asistido por Computadora , Materiales Dentales , Ensayo de Materiales
4.
Gen Dent ; 72(5): 54-59, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39151083

RESUMEN

A conservative approach to restoration assists in preserving the remaining tooth structure of extensively destroyed vital teeth. This case report describes a single-appointment chairside technique for placement of ceramic restorations in posterior teeth. A patient presented for treatment of her mandibular right first molar, which had a fractured resin-based composite restoration. Due to the presence of vital pulp, extent of the restoration, and presence of caries in the tooth, the following treatment plan was proposed: placement of a lithium disilicate glass-ceramic onlay fabricated with a computer-aided design/computer-aided manufacturing workflow. After the dentist removed the restoration and performed selective caries removal, structural analysis guided the reduction of the buccal cusps. Immediate dentin sealing was performed with a 2-step self-etching adhesive system, and a 1-mm-thick layer of flowable resin-based composite was placed as a resin coating. A digital impression was obtained, the onlay restoration was designed, and a lithium disilicate block was milled and subsequently crystallized. When the onlay was completed, the tooth preparation was sandblasted, selectively etched, and coated with a universal adhesive. The intaglio surface of the onlay was cleaned and primed, the onlay was bonded with dual-cure resin cement, and occlusal adjustments were completed. Follow-up examinations at 1 and 4 months revealed the clinical success of the case. From start to finish, it takes approximately 2.5 hours to produce a single-appointment chairside restoration. The technique used in this case offers a fast-paced workflow that is comfortable and practical for the patient and provides a predictable clinical outcome without the need for a temporary restoration.


Asunto(s)
Cerámica , Resinas Compuestas , Diseño Asistido por Computadora , Incrustaciones , Humanos , Resinas Compuestas/uso terapéutico , Femenino , Cerámica/uso terapéutico , Fracaso de la Restauración Dental , Diente Molar , Porcelana Dental/uso terapéutico , Restauración Dental Permanente/métodos
5.
J Contemp Dent Pract ; 25(2): 107-113, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38514406

RESUMEN

AIM: This study aimed to compare the efficacy of autogenous onlay and inlay grafts for anterior maxillary horizontal ridge augmentation. MATERIALS AND METHODS: This randomized clinical trial was performed on 14 patients with a deficient partially edentulous anterior maxillary ridge (3-5 mm in width). Patients were randomized and grouped into two equal groups: Group A was treated with symphyseal autogenous bone block, which was placed and fixed buccally as an onlay graft, and group B: was treated with symphyseal autogenous bone block, which was interpositioned and fixed in space created between buccal and lingual cortex as inlay graft. Patients were evaluated clinically and radiographically to evaluate the increase of bone width at [Baseline, immediate postoperative (T0)] and six months post-graft (T6). RESULTS: A total of 14 patients (8 males and 6 females) with age range from 20 to 43 years old with a mean of 42.1 years were involved in our study. Radiographically, there was a significant statistical difference in comparing between two groups for the creation of a horizontal alveolar bone at T0. In the inlay group, the mean preoperative bone width was 3.9 ± 0.3 mm at T0 and 5.7 ± 0.5 mm at T6. While in the onlay group, the mean preoperative bone width was 3.7 ± 0.7 mm at T0 while at T6 the mean bone width was 6.1 ± 0.8 mm. This was statistically significant. CONCLUSION: Inlay block graft appears to be a successful treatment option for horizontal ridge augmentation in the maxillary arch. CLINICAL SIGNIFICANCE: both techniques are viable techniques for augmentation of atrophic alveolar ridge with uneventful healing. How to cite this article: Elsayed AO, Abdel-Rahman FH, Ahmed WMAS, et al. Clinical and Radiographic Outcomes of Autogenous Inlay Graft vs Autogenous Onlay Graft for Anterior Maxillary Horizontal Ridge Augmentation: A Randomized Control Clinical Study. J Contemp Dent Pract 2024;25(2):107-113.


Asunto(s)
Aumento de la Cresta Alveolar , Incrustaciones , Masculino , Femenino , Humanos , Adulto Joven , Adulto , Trasplante Óseo/métodos , Aumento de la Cresta Alveolar/métodos , Proceso Alveolar/cirugía , Cicatrización de Heridas , Maxilar/cirugía , Implantación Dental Endoósea
6.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(1): 111-120, 2024 Feb 01.
Artículo en Inglés, Zh | MEDLINE | ID: mdl-38475959

RESUMEN

Noncarious lesions, a multifactorial condition encompassing tooth attrition, abrasion, and erosion, have a surge in prevalence and required increased attention in clinical practice. These nonbacterial-associated tooth defects can compromise aesthetics, phonetics, and masticatory functions. When providing full-arch fixed occlusal rehabilitation for such cases, the treatment strategy should extend beyond by restoring dentition morphology and aesthetics. This report details a complex case of erosive dental wear addressed through a fully digital, full-arch fixed occlusal rehabilitation. A 4D virtual patient was created using multiple digital data sources, including intraoral scanning, 3D facial scanning, digital facebow registration, and mandibular movement tracing. With a comprehensive understanding of the masticatory system, various types of microinvasive prostheses were customized for each tooth, including labial veneers, buccal-occlusal veneers, occlusal veneers, overlays, inlays, and full crowns, were customized for each tooth. The reported digital workflow offered a predictable diagnostic and treatment strategy, which was facilitated by virtual visualization and comprehensive quality control throughout the process.


Asunto(s)
Atrición Dental , Erosión de los Dientes , Humanos , Erosión de los Dientes/patología , Erosión de los Dientes/terapia , Tecnología Digital , Estética Dental , Incrustaciones
7.
Int J Prosthodont ; 37(7): 79-88, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38498860

RESUMEN

PURPOSE: To compare the accuracy of 12 different dental restorations fabricated with milling or 3D-printed molds and robotically controlled casting. MATERIALS AND METHODS: Twelve dental restorations (11 inlays and onlays and 1 crown) were made per restoration type, one per each of the 12 different teeth models (total of 24 restorations). On each tooth preparation, two restorations were manufactured using different CAD/ CAM techniques: (1) milling and (2) robotically controlled casting and 3D-printed molds. In addition, twolayer restorations were manufactured with 3D-printed molds. The marginal and internal gaps were evaluated at 120 points per restoration based on micro-CT 3D imaging. Internal gaps were evaluated using a replica technique with silicone. RESULTS: Median values (interquartile ranges) for marginal gaps, middle internal gaps, and central internal gaps were significantly lower for 3D-printed mold restorations (44.3 [65.4] µm, 95.4 [96.2] µm, and 104.6 [78.1] µm) compared to milled restorations (58.4 [93] µm, 145.9 [85.8] µm, and 138.6 [65.7] µm). Internal gaps in the 3D-printed mold group were 6% to 51% smaller than in the milled group. CONCLUSIONS: The accuracy of restorations fabricated with 3D-printed molds may be preferable compared to milled restorations, except in the case of crown restoration. However, additional studies with a larger number of samples and different types of restorations are needed to confirm the results.


Asunto(s)
Diseño Asistido por Computadora , Adaptación Marginal Dental , Proyectos Piloto , Incrustaciones , Coronas , Impresión Tridimensional , Diseño de Prótesis Dental/métodos
8.
Dent Mater ; 40(4): 643-652, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38383250

RESUMEN

OBJECTIVES: Zein-coated magnesium oxide nanoparticles (zMgO NPs) can potentially improve cement adaptation to the tooth-restoration interface, which would aid in minimizing marginal leakage and secondary caries. The aim of this study was to assess the effect of incorporating zMgO NPs on the adaptation of self-adhesive resin cement using cross-polarization optical coherence tomography (CP-OCT) and scanning electron microscopy (SEM). METHODS: Resin inlays were fabricated to be cemented in Class-I cavities of extracted human molars. All specimens were randomly divided into five groups (n = 10), and the resin inlays were cemented using self-adhesive resin cement with various concentrations of zMgO NPs (0% [control], 0.3%, 0.5%, 1%, 2%). Characterization was done by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and SEM. The specimens were examined for interfacial adaptation under CP-OCT. Floor and wall adaptation measurements were analyzed by software on 20 B-scans, and samples were sectioned for interfacial measurement by SEM. RESULTS: Results for CP-OCT and SEM showed a statistically significant increase of adaptation in the floor and wall of resin cement filled with zMgO NPs compared to the control. The samples enhanced with 0.3% and 0.5% showed a statistically significantly better adaptation in floor and wall in CP-OCT and SEM. However, there was no significant difference between the 1%, 2%, and control groups for CP-OCT and SEM analysis. SIGNIFICANCE: The incorporation of zMgO NPs in self-adhesive resin cement can enhance the cement's properties by significantly improving its wall and floor adaptation.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Humanos , Cementos de Resina/química , Cementos Dentales , Tomografía de Coherencia Óptica/métodos , Incrustaciones , Cementos de Ionómero Vítreo , Resinas Compuestas/química , Adaptación Marginal Dental
9.
Int J Prosthodont ; 37(2): 173-180, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38648165

RESUMEN

PURPOSE: To evaluate the marginal integrity of three inlay-retained fixed dental prosthesis (IRFDP) designs fabricated using monolithic zirconia. MATERIALS AND METHODS: In total, 30 IRFDPs were fabricated using 4-YTZP monolithic zirconia and randomly divided into three groups according to the cavity design. Groups ID2 and ID1.5 received an inlay cavity preparation, which includes a proximal box and an occlusal extension with a depth of 2 mm or 1.5 mm, respectively. Group PB received a proximal box cavity preparation without an occlusal extension. The restorations were fabricated and cemented using a dual-cure resin cement (Panavia V5) and subjected to an equivalent of 5 years of aging. The specimens were evaluated under an SEM to measure marginal continuity before and after the aging process. RESULTS: During the whole 5-year aging process, no specimens showed signs of cracking, fracture, or loss of retention in any restorations. In the SEM analysis, most marginal defects observed in the restorations were areas of microgaps at the tooth/cement interface (TC) or zirconia/cement interface (ZC), resulting in loss of adaptation. There was a significant difference between the groups after the aging process at both the TC (F = 4.762, P < .05) and ZC (F = 6.975, P < .05), with Group ID2 presenting the best performance. There was a significant difference between TC and ZC in all groups (P < .05), with ZC presenting more gaps in all groups. CONCLUSIONS: Inlay cavity designs including a proximal box and an occlusal extension exhibited better marginal stability than a proximal box without occlusal extension.


Asunto(s)
Incrustaciones , Circonio , Circonio/química , Humanos , Técnicas In Vitro , Adaptación Marginal Dental , Diseño de Prótesis Dental , Diseño de Dentadura , Dentadura Parcial Fija , Materiales Dentales/química
10.
Shanghai Kou Qiang Yi Xue ; 33(2): 200-204, 2024 Apr.
Artículo en Zh | MEDLINE | ID: mdl-39005100

RESUMEN

PURPOSE: To analyse the types of chairside CAD/CAM all-ceramic restorations and the color range of all-ceramic materials used so as to provide reference for the application of clinical chairside all-ceramic restoration and the color selection of all-ceramic materials. METHODS: IPS e.max CAD prostheses and related data were collected from January 2021 to December 2021 from the Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine. The number and type of restorations and the color of materials were investigated and analyzed by descriptive statistics. RESULTS: A total of 1 374 restorations were included, of which 624 were crown restorations, accounting for 45.41% of the total restorations. 516 cases were veneer, accounting for 37.55%; 219 were inlays, accounting for 15.94%; fixed bridges were all adhesive bridges, with the least number with only 15 cases, accounting for 1.09%. In terms of the selection of restoration materials, the use rate of low-transparent(LT) ceramic blocks was significantly higher than that of other transparent ceramic blocks. A was the most frequently used ceramic color. The most frequently used porcelain blocks for veneers were LTA2 and LTA1; for inlay were LTA3; for crowns were LTA2 and LTA3. The blocks used in the fixed bridges were all LT, and A3 color was the majority. CONCLUSIONS: Chairside CAD/CAM all-ceramic prostheses made of IPS e.max CAD materials have been widely used in clinical practice. The types of prostheses include veneer, inset, crown and fixed bridge. The most commonly used IPS e.max CAD blocks are LTA2, LTA3 and LTA1. These findings have certain guiding significance for the clinical restoration decision and the reserve of porcelain blocks in primary hospitals.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Coronas , Cerámica/química , Diseño de Prótesis Dental/métodos , Porcelana Dental/química , Color , Humanos , Coronas con Frente Estético , Incrustaciones/métodos , Restauración Dental Permanente/métodos
11.
Dent Mater J ; 43(3): 407-414, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38644215

RESUMEN

This study aimed to evaluate the effects of different resin-coating technique strategies and dual-cure resin luting materials on proximal marginal adaptation and the microtensile bond strengths (µTBSs) of CAD/CAM hybrid ceramic inlays. Extracted human molars were classified into four groups, depending on the coating technique: No coating (None), single coating (1-coating), double coating (2-coating), and flowable resin-coating (Combination). The inlays were bonded with one of the three materials: Panavia V5 (V5), Rely X Ultimate (RXU), and Calibra Ceram (CC). The differences with regard to adaptation were not significant. In the case of µTBS data for V5, no significant differences were observed, whereas for RXU, µTBS values for Combination statistically exceeded those for None and 1-coating. For CC, µTBS values for Combination statistically exceeded those for None, 1-coating, and 2-coating. The coating techniques did not influence the adaptation but influenced the bond strength, and Combination performed the best.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Recubrimiento Dental Adhesivo , Adaptación Marginal Dental , Incrustaciones , Ensayo de Materiales , Diente Molar , Cementos de Resina , Propiedades de Superficie , Resistencia a la Tracción , Humanos , Cerámica/química , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Técnicas In Vitro , Análisis del Estrés Dental , Porcelana Dental/química
12.
J Dent ; 148: 105244, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39068858

RESUMEN

OBJECTIVES: To evaluate the fabrication trueness of additively manufactured maxillary definitive casts with various tooth preparations fabricated with different 3-dimensional (3D) printers and print orientations. METHODS: A maxillary typodont with tooth preparations for a posterior 3-unit fixed partial denture, lateral incisor crown, central incisor and canine veneers, first premolar and second molar inlays, and a first molar crown was digitized with an industrial scanner. This scan file was used to fabricate definitive casts with a digital light processing (DLP) or stereolithography (SLA) 3D printer in different orientations (0-degree, 30-degree, 45-degree, and 90-degree) (n = 7). All casts were digitized with the same scanner, and the deviations within each preparation site were evaluated. Generalized linear model analysis was used for statistical analysis (α = 0.05). RESULTS: The interaction between the 3D printer and the print orientation affected measured deviations within all preparations (P ≤ 0.001) except for the lateral incisor crown and canine veneer (P ≥ 0.094), which were affected only by the main factors (P < 0.001). DLP-90 mostly led to the highest and DLP-0 mostly resulted in the lowest deviations within posterior tooth preparations (P ≤ 0.014). DLP-30 led to the lowest deviations within the first premolar inlay and DLP-45 led to the lowest deviations within the central incisor veneer preparation (P ≤ 0.045). CONCLUSIONS: Posterior preparations of tested casts had the highest trueness with DLP-0 or DLP-30, while central incisor veneer preparations had the highest trueness with DLP-45. DLP-90 led to the lowest trueness for most of the tooth preparations. CLINICAL SIGNIFICANCE: Definitive casts with tooth preparations fabricated with the tested DLP 3D printer and the print orientation adjusted on tooth preparation may enable well-fitting restorations. However, 90-degree print orientation should be avoided with this 3D printer, as it led to the lowest fabrication trueness.


Asunto(s)
Diseño Asistido por Computadora , Coronas con Frente Estético , Modelos Dentales , Impresión Tridimensional , Humanos , Diente Molar , Incisivo/anatomía & histología , Dentadura Parcial Fija , Incrustaciones , Preparación Protodóncica del Diente/métodos , Estereolitografía , Diseño de Prótesis Dental , Diente Canino/anatomía & histología , Diente Premolar , Maxilar/anatomía & histología , Corona del Diente/anatomía & histología , Técnica de Impresión Dental/instrumentación , Técnica de Colado Dental , Procesamiento de Imagen Asistido por Computador/métodos , Coronas
13.
Artículo en Inglés | WPRIM | ID: wpr-1007937

RESUMEN

OBJECTIVES@#This study aimed to explore the stress distribution of surface-mounted inlays with two ceramic materials and different strategies for fiber post-restoration on pulp-penetrating non-carious cervical lesion in a maxillary first premolar to provide minimally invasive and reasonable restorative methods.@*METHODS@#The cone beam computed tomography data of the standard right upper first premolar were selected. Healthy control (HC) and defective control (DC) finite element models were established. Then, eight experimental models were established according to two different ceramic materials (IPS e.max CAD [LD] and Lava Ultimate [LU]) and different locations of fiber post (without fiber post [NP], fiber post in buccal root canal [B], fiber post in palatal root canal [P], fiber post in both root canals [BP]), namely, LDNP, LDB, LDP, LDBP, LUNP, LUB, LUP, and LUBP. Axial load F1 and lateral load F2 were applied. Maximum principal stress and displacement of the buccal tip were investigated using finite element analysis software. Then, the percentage change of the following indicators in each experimental group was analyzed: stress of defective tip with group DC, stress of enamel and dentine, and displacement of buccal tips with group HC. It was considered similar when the percentage change was less than 5%.@*RESULTS@#LD and LU groups could effectively reduce the stress of the defective tip, but the decreasing amplitude in the former was greater than that of the latter. For the stress of surface-mounted inlays and resin adhesive layer, LD groups were higher than LU groups, and no significant difference in stress peak was found among different experimental groups in the same material. In addition, fiber posts in double root canals could significantly reduce buccal tip displacement.@*CONCLUSIONS@#For pulp-penetrating non-carious cervical lesions, the restorative strategy of surface-mounted inlays could be applied. Compared with Lava Ultimate, IPS e.max CAD could better protect the defective tip tooth. Furthermore, fiber posts in double root canals could decrease overall deformation and increase the retention of surface-mounted inlays.


Asunto(s)
Incrustaciones , Análisis de Elementos Finitos , Resinas Compuestas , Diente Premolar , Cerámica , Análisis del Estrés Dental
14.
Braz. j. oral sci ; 21: e228852, jan.-dez. 2022. ilus
Artículo en Inglés | LILACS, BBO - odontología (Brasil) | ID: biblio-1392917

RESUMEN

Aim: To evaluate the occlusal and internal marginal adaptation of inlay restorations made of different materials, using CAD-CAM. Methods: Preparations were made for MOD inlays of one-third intercuspal width and 4 mm depth in 30 third human molars. The teeth were restored using CAD-CAM materials (n=10) of nanoceramic resin (Lava Ultimate), polymer-infiltrated ceramic network (VITA ENAMIC), or lithium disilicate glass-ceramic (IPS e.max CAD). The specimens were cemented with dual resin cement and sectioned at the center of the restoration, after which the two halves were evaluated, and photographed The occlusal and internal discrepancy (µm) was determined at five points: cavosurface angle of the occlusal-facial wall (CA-O); center of the facial wall (FW); faciopulpal angle (FPA); center of the pulpal wall (PW); and center of the lingual wall (LW). The data were submitted to the Kruskal-Wallis and the Dunn tests (α=0.05). Results: No difference was observed among the materials regarding the occlusal discrepancy at the CA-O, FPA, or PW internal points. The e.max CAD measurement at FW showed larger internal discrepancy than that of Lava (p=0.02). The internal discrepancy at LW was greater for e.max CAD than VITA ENAMIC (p=0.02). Conclusion: Lithium disilicate glass-ceramic presented greater internal discrepancy in relation to the surrounding walls of the inlay preparations


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Adaptación Marginal Dental , Materiales Dentales , Incrustaciones
15.
Rev. odontol. UNESP (Online) ; 51: e20220016, 2022. tab
Artículo en Inglés | LILACS, BBO - odontología (Brasil) | ID: biblio-1424227

RESUMEN

Introduction: composite resins are materials widely used for Class II restorations, to restore the anatomization of the dental element. However, there are several factors that can interfere with the quality of a good restoration. Objective: the objective of the present study is to carry out a retrospective evaluation of the clinical performance of Class II restorations performed by undergraduate students of Dentistry at the Escola São Francisco de Assis (ESFA), and to identify the main errors. Material and method: we selected the medical records of patients treated in the disciplines of Dentistry II, Integrated I and II in the Dentistry clinic at ESFA, which presented detailed information on the Class II procedure, as well as initial radiographic examinations, using the FDI method. The sample consisted of 33 medical records that included 72 teeth. Result: it was observed that more than 80% of the restorations were classified as acceptable. And, only 19.44% of the restorations were unacceptable, failing due to functional and biological properties. Conclusion: it was found that undergraduate students in Dentistry at ESFA, who are guided by professors to perform treatments following pre-established clinical protocols, are capable of carrying out quality restorative procedures.


Introdução: as resinas compostas são materiais muito utilizados para restaurações Classe II, com função de restabelecer a anatomização do elemento dental. No entanto, diversos são os fatores que podem interferir na qualidade de uma boa restauração. Objetivo: o objetivo do presente estudo é realizar uma avaliação retrospectiva do desempenho clínico de restaurações Classe II executadas por alunos da graduação de Odontologia da Escola São Francisco de Assis (ESFA) e identificar as principais falhas cometidas. Material e método: foram selecionados os prontuários dos pacientes atendidos nas disciplinas de Dentística II, Integrada I e II na clínica de Odontologia da ESFA, que apresentaram as informações detalhadas do procedimento de Classe II, bem como exames radiográficos iniciais, usando o método FDI. A amostra foi composta por 33 prontuários que incluíam 72 dentes. Resultado: observou-se que mais de 80% das restaurações foram classificadas como aceitáveis. Visto que, apenas 19,44% das restaurações estiveram inaceitáveis, pecando para as propriedades funcionais e biológicas. Conclusão: constatou-se que os alunos da graduação em Odontologia da ESFA, os quais são orientados por professores a realizar tratamentos seguindo protocolos clínicos pré-estabelecidos, são capazes de confeccionar procedimentos restauradores de qualidade.


Asunto(s)
Estudiantes de Odontología , Interpretación Estadística de Datos , Adaptación Marginal Dental , Resinas Compuestas , Incrustaciones
16.
Braz. dent. sci ; 25(3): 1-10, 2022. ilus
Artículo en Inglés | LILACS, BBO - odontología (Brasil) | ID: biblio-1381618

RESUMEN

The clinical success of tooth-colored indirect restorations has been confirmed in several studies. However, inlays and onlays restorations in Class II cavities with deep gingival margins can still be considered a clinical challenge. With the purpose of facilitating the execution of the operative procedures in intrasulcular margins and reducing the risk of restorative failures, the technique of cervical margin relocation has been explored as a noninvasive alternative to surgical crown lengthening. This work aims at discussing through a case report the biomechanical, operative and biological aspects in the treatment of teeth with deep gingival margins. Therefore, given the therapy applied in the clinical case presented, it is concluded that the cervical margin relocation with composite resin is advantageous since it eliminates the need for surgery, allowing the implementation of indirect restorations in fewer clinical sessions, not causing damage to periodontal tissues once it provided good finishing and polishing with the establishment of a correct emergence profile, allowing flawless maintenance of gingival health after one year. (AU)


Sucesso clínico das restaurações indiretas livres de metal tem sido confirmado em diversos estudos. No entanto, restaurações parciais indiretas em cavidades do tipo classe II com margens profundas ainda podem ser consideradas um desafio clínico. Com a proposta de facilitar a execução dos procedimentos operatórios em margens intra-sulculares e reduzir a ocorrência de falhas, a técnica de elevação da margem gengival em resina composta tem sido explorada como alternativa não invasiva à cirurgia de aumento de coroa clínica. Este trabalho tem a intenção de discutir através de um relato de caso clínico os aspectos biomecânicos, operatórios e biológicos no tratamento de dentes com margens cervicais profundas. Sendo assim, conclui-se que a técnica de elevação da margem gengival com resina composta é vantajosa, pois elimina a necessidade de cirurgia permitindo a execução de restaurações indiretas em menos sessões clínicas, não gerando danos aos tecidos periodontais, desde que haja um bom acabamento e polimento, com estabelecimento de um correto perfil de emergência. (AU)


Asunto(s)
Humanos , Femenino , Adulto , Adaptación Marginal Dental , Resinas Compuestas , Fracaso de la Restauración Dental , Preparación de la Cavidad Dental , Incrustaciones
17.
Braz. dent. sci ; 25(2): 1-8, 2022. ilus, tab
Artículo en Inglés | LILACS, BBO - odontología (Brasil) | ID: biblio-1368244

RESUMEN

Increasing prevalence of erosive tooth wear (ETW) is notable mainly due to current knowledge and its early diagnosis. Once teeth are functionally and/or esthetically affected, dental restorations may become necessary. Materials capable of interacting with the eroded dental tissue allied to their resistance to subsequent continuous erosive challenges are desirable. Giomer technology based on S-PRG (surface pre-reactive glass) filler has been launching to provide benefits for the dental treatment due to its innovative multi-ionic release system, which involves fluoride. This case report describes the employment of preventive and restorative materials based on this technology for a patient under frequent erosive challenges and complaining about dental sensitivity. Patient reported immediate reduction on this sensitivity and the restorations has been followed up for 2 years, presenting satisfactory performance. S-PRG-based systems seem to be promissory for preventive and therapeutic management of ETW used simultaneously with the patient compliance. (AU)


O aumento da prevalência do desgaste dentário erosivo (DDE) é notável especialmente devido ao conhecimento atual e seu diagnóstico precoce. Uma vez que os dentes são afetados funcional e/ou esteticamente, restaurações dentárias se tornam necessárias. Materiais focados na habilidade de interagir com o tecido dentário erodido associados com sua resistência aos desafios erosivos contínuos subsequentes são desejáveis. A tecnologia Giomer baseada em partículas S-PRG (superfície de vidro pré-reativo) foi lançada no mercado para oferecer benefícios para o tratamento odontológico devido ao seu sistema inovador de liberação multi-iônica, que envolve o flúor. Esse caso clínico descreve o uso de materiais preventivo e restaurador baseados nessa tecnologia em um paciente em desafio erosivo e com queixa de sensibilidade. O paciente relatou redução imediata da sensibilidade e as restaurações foram acompanhadas por 2 anos apresentando desempenho satisfatório. Sistemas baseados em S-PRG se mostram promissores para manejo preventivo e terapêutico do DDE empregados simultaneamente à colaboração do paciente.(AU)


Asunto(s)
Humanos , Masculino , Adulto , Erosión de los Dientes , Materiales Biocompatibles , Polímeros de Estímulo Receptivo , Incrustaciones
18.
Rev. Odontol. Araçatuba (Impr.) ; 42(2): 24-29, maio-ago. 2021. ilus
Artículo en Portugués | LILACS, BBO - odontología (Brasil) | ID: biblio-1252903

RESUMEN

Na Odontologia, o tratamento adequado depende da condição clínica de cada paciente, do conhecimento do profissional e dos materiais empregados. As coroas com sistemas cerâmicos puros se apresentam como excelente alternativa restauradora, demonstrando potencial estético superior ao das coroas metalocerâmicas. Este presente estudo teve como objetivo, relatar um caso clínico onde se realizou uma reabilitação estética de dentes anteriores com coroas de cerâmica pura à base de dissilicato de lítio. O paciente apresentava falta de harmonia e estética entre os dentes anteriores 12,11,21 e 22, na qual foi planejado e executado a reabilitação com coroas E-max desses elementos, bem como a substituição das restaurações dos dentes inferiores anteriores, e também foi realizado a confecção de coroa E-max do dente 35. Concluímos que as reabilitações estéticas de dentes anteriores com coroas de sistemas cerâmicos puros à base de dissilicato de lítio se apresentam como uma excelente alternativa reabilitadora, na qual o tratamento multidisciplinar é um fator considerado essencial, possibilitando restabelecer a estética e a funcionalidade do sorriso do paciente, a fim de alcançar o êxito do tratamento reabilitador(AU)


In dentistry, the appropriate treatment depends on the clinical condition of each patient, the knowledge of the professional and the materials used. Crowns with pure ceramic systems are an excellent restorative alternative, demonstrating an aesthetic potential superior to that of metalloceramic crowns. This present study aimed to report a clinical case where an aesthetic rehabilitation of anterior teeth was performed with crowns of pure ceramic based on lithium disilicate. The patient had a lack of harmony and aesthetics between the anterior teeth 12,11,21 and 22, in which the rehabilitation with E-max crowns of these elements was planned and performed, as well as the replacement of the anterior lower teeth restorations, and was also made the E-max crown of tooth 35. We conclude that the aesthetic rehabilitation of anterior teeth with crowns of pure ceramic systems based on lithium disilicate is an excellent alternative for rehabilitation, in which multidisciplinary treatment is considered an essential factor, making it possible to restore the aesthetics and functionality of the patient's smile, in order to achieve the success of the rehabilitation treatment(AU)


Asunto(s)
Humanos , Masculino , Adulto , Cerámica , Coronas , Rehabilitación Bucal , Restauración Dental Permanente , Estética Dental , Incrustaciones
19.
Braz. dent. j ; 32(2): 53-63, Mar.-Apr. 2021. tab, graf
Artículo en Inglés | LILACS, BBO - odontología (Brasil) | ID: biblio-1339327

RESUMEN

Abstract The present study was a prospective, controlled, randomized, clinical short-term trial aiming to evaluate the clinical performance of adhesively luted, lithium disilicate and feldspathic glass-ceramics onlays over a period up to 2 years. A total of 11 patients (7 female, 4 male; age range: 18-60 years, mean age: 39 years) were selected for this study. Each patient received a maximum of two restorations per group in a split-mouth-design. LD: Eleven onlays, performed with lithium disilicate-based ceramic (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein), and FP: Eleven onlays, performed with feldspathic ceramic (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Recalls were performed at 2 weeks (baseline = R1), 1 year (R2) and 2 years (R3) after the cementation by three calibrated blinded independent investigators using mirrors, magnifying eyeglasses, probes and bitewing radiographs. The postoperative sensitivity, secondary caries, marginal integrity, marginal discoloration, color match, surface roughness, tooth integrity, and restoration integrity were evaluated. The Friedman test was used to determine if there was a statistically significant difference in time-to-time comparison of the parameters in the ceramics restorations. A total of 95.4% of the restorations were clinically acceptable at the 2-year recall, without a difference for any evaluation parameter for both ceramic materials. Based on the 2-year data, the CAD-CAM onlays manufactured with feldspathic and lithium-disilicate based ceramics showed similar clinical performance.


Resumo O presente estudo é um estudo clínico prospectivo, controlado, randomizado e de longo curto prazo, com o objetivo de avaliar o desempenho clínico de restauraç ões adesivas cerâmica vítrea reforçada com dissilicato de lítio e cerâmica feldspática por um período de até 2 anos. Um total de 11 pacientes (7 mulheres, 4 homens; faixa etária: 18-60 anos, idade média: 39 anos) foram inseridas para este estudo. Cada paciente recebeu duas restaurações por grupo em um delineamento de boca dividida. LD: Onze onlays, realizados com cerâmica à base de dissilicato de lítio (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein); e FP: Onze onlays, realizados com cerâmica feldspática (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Os retornos foram realizados em 2 semanas (linha de base = R1), 1 ano (R2) e 2 anos (R3) após a cimentação, por três investigadores independentes, cegos e calibrados, usando espelhos, óculos de aumento, sondas e radiografias interproximais. Foram avaliadas a sensibilidade pós-operatória, cárie secundária, integridade marginal, descoloração marginal, correspondência de cores, rugosidade da superfície, integridade dentária e integridade da restauração. O teste de Friedman (95%) foi utilizado para determinar se havia uma diferença estatisticamente significante na comparação periódica dos parâmetros nas restaurações cerâmicas. Um total de 95,4% das restaurações estava clinicamente aceitável no retorno de 2 anos, sem diferença para qualquer parâmetro de avaliação para ambos os materiais cerâmicos. Com base nos dados de 2 anos, as restaurações CAD-CAM fabricados com cerâmica feldspática e à base de dissilicato de lítio apresentaram desempenho clínico semelhante.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Adulto Joven , Incrustaciones , Boca , Estudios Prospectivos , Porcelana Dental
20.
Rev. Fac. Odontol. (B.Aires) ; 36(83): 57-66, 2021. ilus
Artículo en Español | LILACS | ID: biblio-1343658

RESUMEN

El objetivo de este reporte de caso clínico es presentar una rehabilitación integral adhesiva resuelta por alumnos de grado de la Facultad de Odontología de la Universidad de Buenos Aires (FOUBA), bajo un protocolo de abordaje terapéutico que simplifica su realización. Esta sistematización hace foco en un abordaje completamente aditivo con la finalidad de devolver la salud, la función y la estética de manera predecible. Un paciente de 55 años concurrió a la consulta por motivos estéticos. En el diagnóstico se evidenciaron desgastes severos producto de la parafunción. Se realizó una rehabilitación oral adhesiva seleccionando a la cerámica vítrea como material restaurador. El diagnóstico y la comprensión de su etiología son fundamentales para realizar un tratamiento conservador con restauraciones adheridas y con alto grado de predictibilidad, que se prolongará en el tiempo, gracias a la utilización de una placa orgánica y a los controles de mantenimiento correspondientes (AU)


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Bruxismo/rehabilitación , Cerámica , Recubrimiento Dental Adhesivo , Estética Dental , Planificación de Atención al Paciente , Periodontitis/terapia , Argentina , Facultades de Odontología , Preparación de la Cavidad Dental , Tratamiento Conservador , Incrustaciones , Rehabilitación Bucal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA