Effectiveness of lipid microbubbles and ultrasound in declotting thrombosis.
Ultrasound Med Biol
; 31(7): 979-85, 2005 Jul.
Article
in En
| MEDLINE
| ID: mdl-15972204
The objectives of this study were to determine the effectiveness of lipid-encapsulated microbubbles and ultrasound (US) in recanalizing arteriovenous graft thrombi and the effect that tissue attenuation has on the success rate. A total of 55 thrombotic occlusions were created in four canines. The thrombosed grafts were randomly treated with two different 1-MHz US intensities, low (0.4 to 0.6 W/cm(2)) and high (10 W/cm(2)). Intragraft microbubbles were compared with intragraft saline and with the same dose of microbubbles given IV. IV microbubbles were also given both in the presence and absence of a tissue-mimicking phantom. High-intensity US (10 W/cm(2)) with intragraft microbubbles produced significantly higher patency and flow scores than did US with saline (p < 0.01). US with IV microbubbles had higher success rates in recanalizing thrombosed grafts than did US alone at all intensities. Attenuation reduced the rate at which successful recanalization occurred at both low and high intensities. US and microbubbles are capable of recanalizing acute arteriovenous graft thromboses. Higher intensities may be needed in the presence of tissue attenuation.
Search on Google
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Thrombosis
/
Ultrasonic Therapy
/
Microbubbles
/
Graft Occlusion, Vascular
Type of study:
Diagnostic_studies
/
Evaluation_studies
Limits:
Animals
Language:
En
Journal:
Ultrasound Med Biol
Year:
2005
Type:
Article
Affiliation country:
United States