Your browser doesn't support javascript.
loading
Segmentation of arterial vessel wall motion to sub-pixel resolution using M-mode ultrasound.
Fancourt, Craig; Azer, Karim; Ramcharan, Sharmilee L; Bunzel, Michelle; Cambell, Barry R; Sachs, Jeffrey R; Walker, Matthew.
Affiliation
  • Fancourt C; Merck Research Labs, Rahway, NJ, USA.
Article in En | MEDLINE | ID: mdl-19163372
ABSTRACT
We describe a method for segmenting arterial vessel wall motion to sub-pixel resolution, using the returns from M-mode ultrasound. The technique involves measuring the spatial offset between all pairs of scans from their cross-correlation, converting the spatial offsets to relative wall motion through a global optimization, and finally translating from relative to absolute wall motion by interpolation over the M-mode image. The resulting detailed wall distension waveform has the potential to enhance existing vascular biomarkers, such as strain and compliance, as well as enable new ones.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arteries / Image Processing, Computer-Assisted / Biomarkers / Ultrasonography Type of study: Diagnostic_studies / Prognostic_studies Limits: Animals / Humans Language: En Journal: Annu Int Conf IEEE Eng Med Biol Soc Year: 2008 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arteries / Image Processing, Computer-Assisted / Biomarkers / Ultrasonography Type of study: Diagnostic_studies / Prognostic_studies Limits: Animals / Humans Language: En Journal: Annu Int Conf IEEE Eng Med Biol Soc Year: 2008 Type: Article Affiliation country: United States