Your browser doesn't support javascript.
loading
Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.
JAMA ; 308(8): 777-87, 2012 Aug 22.
Article in En | MEDLINE | ID: mdl-22910755
CONTEXT: The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE: To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS: A prospective, randomized, single-blinded, controlled trial of 1161 patients presenting with STEMI at 11 sites in Europe and Israel between September 19, 2009, and January 25, 2011. Clinical follow-up was performed at 1 and 12 months. INTERVENTION: Patients were randomized 1:1 to receive the biolimus-eluting stent (n = 575) or the bare-metal stent (n = 582). MAIN OUTCOME MEASURES: Primary end point was the rate of major adverse cardiac events, a composite of cardiac death, target vessel-related reinfarction, and ischemia-driven target-lesion revascularization at 1 year. RESULTS: Major adverse cardiac events at 1 year occurred in 24 patients (4.3%) receiving biolimus-eluting stents with biodegradable polymer and 49 patients (8.7%) receiving bare-metal stents (hazard ratio [HR], 0.49; 95% CI, 0.30-0.80; P = .004). The difference was driven by a lower risk of target vessel-related reinfarction (3 [0.5%] vs 15 [2.7%]; HR, 0.20; 95% CI, 0.06-0.69; P = .01) and ischemia-driven target-lesion revascularization (9 [1.6%] vs 32 [5.7%]; HR, 0.28; 95% CI, 0.13-0.59; P < .001) in patients receiving biolimus-eluting stents compared with those receiving bare-metal stents. Rates of cardiac death were not significantly different (16 [2.9%] vs 20 [3.5%], P = .53). Definite stent thrombosis occurred in 5 patients (0.9%) treated with biolimus-eluting stents and 12 patients (2.1%; HR, 0.42; 95% CI, 0.15-1.19; P = .10) treated with bare-metal stents. CONCLUSION: Compared with a bare-metal stent, the use of biolimus-eluting stents with a biodegradable polymer resulted in a lower rate of the composite of major adverse cardiac events at 1 year among patients with STEMI undergoing primary PCI. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00962416.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Myocardial Reperfusion / Sirolimus / Absorbable Implants / Drug-Eluting Stents / Myocardial Infarction Type of study: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: JAMA Year: 2012 Type: Article Affiliation country: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Myocardial Reperfusion / Sirolimus / Absorbable Implants / Drug-Eluting Stents / Myocardial Infarction Type of study: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: JAMA Year: 2012 Type: Article Affiliation country: Switzerland