Your browser doesn't support javascript.
loading
Chemical shift correlations from hyperpolarized NMR using a single SHOT.
Zhang, Guannan; Schilling, Franz; Glaser, Steffen J; Hilty, Christian.
Affiliation
  • Zhang G; Department of Chemistry, Texas A&M University, 3255 TAMU, College Station, Texas 77843-3255, United States.
Anal Chem ; 85(5): 2875-81, 2013 Mar 05.
Article in En | MEDLINE | ID: mdl-23350922
ABSTRACT
A significant challenge in realizing the promise of the dissolution dynamic nuclear polarization technique for signal enhancement in high-resolution NMR lies in the nonrenewability of the hyperpolarized spin state. This property prevents the application of traditional two-dimensional correlation spectroscopy, which relies on regeneration of spin polarization before each successive increment of the indirect dimension. Since correlation spectroscopy is one of the most important approaches for the identification and structural characterization of molecules by NMR, it is important to find easily applicable methods that circumvent this problem. Here, we introduce the application of scaling of heteronuclear couplings by optimal tracking (SHOT) to achieve this goal. SHOT decoupling pulses have been numerically optimized on the basis of optimal control algorithms to obtain chemical shift correlations in C-H groups, either by acquiring a single one-dimensional (13)C spectrum with (1)H off-resonance decoupling or vice versa. Vanillin, which contains a number of functional groups, was used as a test molecule, allowing the demonstration of SHOT decoupling tailored toward simplified and accurate data analysis. This strategy was demonstrated for two cases First, a linear response to chemical shift offset in the correlated dimension was optimized. Second, a pulse with alternating linear responses in the correlated dimension was chosen as a goal to increase the sensitivity of the decoupling response to the chemical shift offset. In these measurements, error ranges of ±0.03 ppm for the indirectly determined (1)H chemical shifts and of ±0.4 ppm for the indirectly determined (13)C chemical shifts were found. In all cases, we show that chemical shift correlations can be obtained from information contained in a single scan, which maximizes the ratio of signal to stochastic noise. Furthermore, a comprehensive discussion of the robustness of the method toward nonideal conditions is included based on experimental and simulated data. Unique features of this technique include the abilities to control the accuracy of chemical shift determination in spectral regions of interest and to acquire such chemical shift correlations rapidly-the latter being of interest for potential application in real-time spectroscopy.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Anal Chem Year: 2013 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Anal Chem Year: 2013 Type: Article Affiliation country: United States