Your browser doesn't support javascript.
loading
Serum neuron-specific enolase levels from the same patients differ between laboratories: assessment of a prospective post-cardiac arrest cohort.
Mlynash, Michael; Buckwalter, Marion S; Okada, Ami; Caulfield, Anna Finley; Venkatasubramanian, Chitra; Eyngorn, Irina; Verbeek, Marcel M; Wijman, Christine A C.
Affiliation
  • Mlynash M; Stanford Neurocritical Care Program, Stanford Stroke Center, Department of Neurology and Neurological Sciences, Stanford University Medical Center, Stanford, CA, USA.
Neurocrit Care ; 19(2): 161-6, 2013 Oct.
Article in En | MEDLINE | ID: mdl-23839710
ABSTRACT

BACKGROUND:

In comatose post-cardiac arrest patients, a serum neuron-specific enolase (NSE) level of >33 µg/L within 72 h was identified as a reliable marker for poor outcome in a large Dutch study (PROPAC), and this level was subsequently adopted in an American Academy of Neurology practice parameter. Later studies reported that NSE >33 µg/L is not a reliable predictor of poor prognosis. To test whether different clinical laboratories contribute to this variability, we compared NSE levels from the laboratory used in the PROPAC study (DLM-Nijmegen) with those of our hospital's laboratory (ARUP) using paired blood samples.

METHODS:

We prospectively enrolled cardiac arrest patients who remained comatose after resuscitation. During the first 3 days, paired blood samples for serum NSE were drawn at a median of 10 min apart. After standard preparation for each lab, one sample was sent to ARUP laboratories and the other to DLM-Nijmegen.

RESULTS:

Fifty-four paired serum samples from 33 patients were included. Although the serum NSE measurements correlated well between laboratories (R = 0.91), the results from ARUP were approximately 30% lower than those from DLM-Nijmegen. Therapeutic hypothermia did not affect this relationship. Two patients had favorable outcomes after hypothermia despite NSE levels measured by DLM-Nijmegen as >33 µg/L.

CONCLUSIONS:

Absolute serum NSE levels of comatose cardiac arrest patients differ between laboratories. Any specific absolute cut-off levels proposed to prognosticate poor outcome should not be used without detailed data on how neurologic outcomes correspond to a particular laboratory's method, and even then only in conjunction with other prognostic variables.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phosphopyruvate Hydratase / Laboratories, Hospital / Chemistry, Clinical / Coma / Clinical Laboratory Services / Heart Arrest Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Humans Language: En Journal: Neurocrit Care Journal subject: NEUROLOGIA / TERAPIA INTENSIVA Year: 2013 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phosphopyruvate Hydratase / Laboratories, Hospital / Chemistry, Clinical / Coma / Clinical Laboratory Services / Heart Arrest Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Humans Language: En Journal: Neurocrit Care Journal subject: NEUROLOGIA / TERAPIA INTENSIVA Year: 2013 Type: Article Affiliation country: United States