Your browser doesn't support javascript.
loading
Aqueductal cerebrospinal fluid pulsatility in healthy individuals is affected by impaired cerebral venous outflow.
J Magn Reson Imaging ; 40(5): 1215-22, 2014 Nov.
Article in En | MEDLINE | ID: mdl-24214844
PURPOSE: To investigate cerebrospinal fluid (CSF) dynamics in the aqueduct of Sylvius (AoS) in chronic cerebrospinal venous insufficiency (CCSVI)-positive and -negative healthy individuals using cine phase contrast imaging. MATERIALS AND METHODS: Fifty-one healthy individuals (32 CCSVI-negative and 19 age-matched CCSVI-positive subjects) were examined using Doppler sonography (DS). Diagnosis of CCSVI was established if subjects fulfilled ≥2 venous hemodynamic criteria on DS. CSF flow and velocity measures were quantified using a semiautomated method and compared with clinical and routine 3T MRI outcomes. RESULTS: CCSVI was associated with increased CSF pulsatility in the AoS. Net positive CSF flow was 32% greater in the CCSVI-positive group compared with the CCSVI-negative group (P = 0.008). This was accompanied by a 28% increase in the mean aqueductal characteristic signal (ie, the AoS cross-sectional area over the cardiac cycle) in the CCSVI-positive group compared with the CCSVI-negative group (P = 0.021). CONCLUSION: CSF dynamics are altered in CCSVI-positive healthy individuals, as demonstrated by increased pulsatility. This is accompanied by enlargement of the AoS, suggesting that structural changes may be occurring in the brain parenchyma of CCSVI-positive healthy individuals.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Venous Insufficiency / Image Processing, Computer-Assisted / Pulsatile Flow / Cerebral Aqueduct / Cerebrospinal Fluid / Cerebrovascular Disorders / Ultrasonography, Doppler, Transcranial / Ultrasonography, Doppler, Color / Magnetic Resonance Imaging, Cine / Hydrocephalus, Normal Pressure Type of study: Diagnostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Magn Reson Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2014 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Venous Insufficiency / Image Processing, Computer-Assisted / Pulsatile Flow / Cerebral Aqueduct / Cerebrospinal Fluid / Cerebrovascular Disorders / Ultrasonography, Doppler, Transcranial / Ultrasonography, Doppler, Color / Magnetic Resonance Imaging, Cine / Hydrocephalus, Normal Pressure Type of study: Diagnostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Magn Reson Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2014 Type: Article