Your browser doesn't support javascript.
loading
Reliability testing of two classification systems for osteoarthritis and post-traumatic arthritis of the elbow.
Amini, Michael H; Sykes, Joshua B; Olson, Stephen T; Smith, Richard A; Mauck, Benjamin M; Azar, Frederick M; Throckmorton, Thomas W.
Affiliation
  • Amini MH; Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA.
  • Sykes JB; Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA.
  • Olson ST; Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA.
  • Smith RA; Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA.
  • Mauck BM; Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA.
  • Azar FM; Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA.
  • Throckmorton TW; Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA. Electronic address: tthrockmorton@campbellclinic.com.
J Shoulder Elbow Surg ; 24(3): 353-7, 2015 Mar.
Article in En | MEDLINE | ID: mdl-25541343
HYPOTHESIS AND BACKGROUND: The severity of elbow arthritis is one of many factors that surgeons must evaluate when considering treatment options for a given patient. Elbow surgeons have historically used the Broberg and Morrey (BM) and Hastings and Rettig (HR) classification systems to radiographically stage the severity of post-traumatic arthritis (PTA) and primary osteoarthritis (OA). We proposed to compare the intraobserver and interobserver reliability between systems for patients with either PTA or OA. METHODS: The radiographs of 45 patients were evaluated at least 2 weeks apart by 6 evaluators of different levels of training. Intraobserver and interobserver reliability were calculated by Spearman correlation coefficients with 95% confidence intervals. Agreement was considered almost perfect for coefficients >0.80 and substantial for coefficients of 0.61 to 0.80. RESULTS: In patients with both PTA and OA, intraobserver reliability and interobserver reliability were substantial, with no difference between classification systems. There were no significant differences in intraobserver or interobserver reliability between attending physicians and trainees for either classification system (all P > .10). The presence of fracture implants did not affect reliability in the BM system but did substantially worsen reliability in the HR system (intraobserver P = .04 and interobserver P = .001). CONCLUSIONS: The BM and HR classifications both showed substantial intraobserver and interobserver reliability for PTA and OA. Training level differences did not affect reliability for either system. Both trainees and fellowship-trained surgeons may easily and reliably apply each classification system to the evaluation of primary elbow OA and PTA, although the HR system was less reliable in the presence of fracture implants.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Osteoarthritis / Elbow Joint / Intra-Articular Fractures / Elbow Injuries Type of study: Diagnostic_studies / Etiology_studies Limits: Humans Language: En Journal: J Shoulder Elbow Surg Journal subject: ORTOPEDIA Year: 2015 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Osteoarthritis / Elbow Joint / Intra-Articular Fractures / Elbow Injuries Type of study: Diagnostic_studies / Etiology_studies Limits: Humans Language: En Journal: J Shoulder Elbow Surg Journal subject: ORTOPEDIA Year: 2015 Type: Article Affiliation country: United States