Your browser doesn't support javascript.
loading
Direct calibration in megavoltage photon beams using Monte Carlo conversion factor: validation and clinical implications.
Wright, Tracy; Lye, Jessica E; Ramanathan, Ganesan; Harty, Peter D; Oliver, Chris; Webb, David V; Butler, Duncan J.
Affiliation
  • Wright T; Australian Radiation Protection and Nuclear Safety Agency, 619 Lower Plenty Rd, Yallambie, Victoria 3085, Australia. School of Chemistry and Physics, University of Adelaide, Adelaide, Australia.
Phys Med Biol ; 60(2): 883-904, 2015 Jan 21.
Article in En | MEDLINE | ID: mdl-25565406
ABSTRACT
The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) has established a method for ionisation chamber calibrations using megavoltage photon reference beams. The new method will reduce the calibration uncertainty compared to a (60)Co calibration combined with the TRS-398 energy correction factor. The calibration method employs a graphite calorimeter and a Monte Carlo (MC) conversion factor to convert the absolute dose to graphite to absorbed dose to water. EGSnrc is used to model the linac head and doses in the calorimeter and water phantom. The linac model is validated by comparing measured and modelled PDDs and profiles. The relative standard uncertainties in the calibration factors at the ARPANSA beam qualities were found to be 0.47% at 6 MV, 0.51% at 10 MV and 0.46% for the 18 MV beam. A comparison with the Bureau International des Poids et Mesures (BIPM) as part of the key comparison BIPM.RI(I)-K6 gave results of 0.9965(55), 0.9924(60) and 0.9932(59) for the 6, 10 and 18 MV beams, respectively, with all beams within 1σ of the participant average. The measured kQ values for an NE2571 Farmer chamber were found to be lower than those in TRS-398 but are consistent with published measured and modelled values. Users can expect a shift in the calibration factor at user energies of an NE2571 chamber between 0.4-1.1% across the range of calibration energies compared to the current calibration method.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Calibration / Water / Monte Carlo Method / Photons / Graphite Type of study: Health_economic_evaluation / Prognostic_studies Limits: Humans Country/Region as subject: Oceania Language: En Journal: Phys Med Biol Year: 2015 Type: Article Affiliation country: Australia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Calibration / Water / Monte Carlo Method / Photons / Graphite Type of study: Health_economic_evaluation / Prognostic_studies Limits: Humans Country/Region as subject: Oceania Language: En Journal: Phys Med Biol Year: 2015 Type: Article Affiliation country: Australia