Your browser doesn't support javascript.
loading
Development of a LC-MS/MS method for simultaneous determination of metoprolol and its metabolites, α-hydroxymetoprolol and O-desmethylmetoprolol, in rat plasma: application to the herb-drug interaction study of metoprolol and breviscapine.
Rao, Zhi; Ma, Yan-rong; Qin, Hong-yan; Wang, Ya-feng; Wei, Yu-hui; Zhou, Yan; Zhang, Guo-qiang; Wang, Xing-dong; Wu, Xin-an.
Affiliation
  • Rao Z; Department of Pharmacy, the First Hospital of Lanzhou University, Lanzhou, 730000, China.
  • Ma YR; Department of Pharmacy, the First Hospital of Lanzhou University, Lanzhou, 730000, China.
  • Qin HY; School of Pharmacy, Lanzhou University, Lanzhou, 730000, China.
  • Wang YF; Department of Pharmacy, the First Hospital of Lanzhou University, Lanzhou, 730000, China.
  • Wei YH; Department of Pharmacy, the First Hospital of Lanzhou University, Lanzhou, 730000, China.
  • Zhou Y; School of Pharmacy, Lanzhou University, Lanzhou, 730000, China.
  • Zhang GQ; Department of Pharmacy, Qinhai Provincial Hospital, Xining, 810007, China.
  • Wang XD; Department of Pharmacy, the First Hospital of Lanzhou University, Lanzhou, 730000, China.
  • Wu XA; Department of Pharmacy, the First Hospital of Lanzhou University, Lanzhou, 730000, China.
Biomed Chromatogr ; 29(9): 1453-60, 2015 Sep.
Article in En | MEDLINE | ID: mdl-25753317
ABSTRACT
A simple, specific and sensitive LC-MS/MS method was developed and validated for the simultaneous determination of metoprolol (MET), α-hydroxymetoprolol (HMT) and O-desmethylmetoprolol (DMT) in rat plasma. The plasma samples were prepared by protein precipitation, then the separation of the analytes was performed on an Agilent HC-C18 column (4.6 × 250 mm, 5 µm) at a flow rate of 1.0 mL/min, and post-column splitting (14) was used to give optimal interface flow rates (0.2 mL/min) for MS detection; the total run time was 8.5 min. Mass spectrometric detection was achieved using a triple-quadrupole mass spectrometer equipped with an electrospray source interface in positive ionization mode. The method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, matrix effect and recovery over a concentration range of 3.42-7000 ng/mL for MET, 2.05-4200 ng/mL for HMT and 1.95-4000 ng/mL for DMT. The analytical method was successfully applied to herb-drug interaction study of MET and breviscapine after administration of breviscapine (12.5 mg/kg) and MET (40 mg/kg). The results suggested that breviscapine have negligible effect on pharmacokinetics of MET in rats; the information may be beneficial for the application of breviscapine in combination with MET in clinical therapy.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Flavonoids / Drugs, Chinese Herbal / Chromatography, High Pressure Liquid / Tandem Mass Spectrometry / Metoprolol Type of study: Evaluation_studies Limits: Animals Language: En Journal: Biomed Chromatogr Year: 2015 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Flavonoids / Drugs, Chinese Herbal / Chromatography, High Pressure Liquid / Tandem Mass Spectrometry / Metoprolol Type of study: Evaluation_studies Limits: Animals Language: En Journal: Biomed Chromatogr Year: 2015 Type: Article Affiliation country: China