Nasal Tip Reconstruction Using Integra Bilayer Wound Matrix: An Alternative to the Forehead Flap.
Eplasty
; 15: e52, 2015.
Article
in En
| MEDLINE
| ID: mdl-26681994
ABSTRACT
UNLABELLED Large defects of the nasal tip with exposure of the underlying cartilage pose a significant reconstructive challenge to the plastic surgeon. OBJECTIVE:
This article presents a case of a large nasal tip defect following basal cell excision that was successfully treated with Integra bilayer wound matrix and skin grafting.METHODS:
Following tumor excision, meshed Integra bilayer wound matrix was placed over the exposed nasal tip cartilage. After 4 weeks, the silicone layer was removed and a full-thickness graft placed on the nasal tip.RESULTS:
This reconstruction resulted in the restoration of patient's nasal tip with good contour and color match without the need for a forehead flap.CONCLUSION:
This demonstrates the reconstructive potential of this modality in patients who are not candidates for reconstruction with a forehead flap.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Language:
En
Journal:
Eplasty
Year:
2015
Type:
Article