Your browser doesn't support javascript.
loading
Surgical anatomy of the pelvic vasculature, with particular reference to acetabular screw fixation in cementless total hip arthroplasty in Asian population.
Ohashi, Hironori; Kikuchi, Shinichi; Aota, Shigeo; Hakozaki, Michiyuki; Konno, Shinichi.
Affiliation
  • Ohashi H; Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan.
  • Kikuchi S; Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan.
  • Aota S; Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan.
  • Hakozaki M; Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan.
  • Konno S; Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan.
J Orthop Surg (Hong Kong) ; 25(1): 2309499016685520, 2017 01 01.
Article in En | MEDLINE | ID: mdl-28498719
PURPOSE: Pelvic vascular injury is a serious complication associated with acetabular component setting with screw fixation in cementless total hip arthroplasty (THA). In this study, we investigated the safety zone for acetabular component setting with screw fixation in cementless THA as a means to prevent pelvic vascular injury. METHODS: Thirty left hip joints of Japanese cadavers (11 males and 19 females) were analyzed. We used a hemispherical measuring cup with 52 guide holes designed to allow vertical insertion of a Kirschner wire. After the measuring cup was placed on the acetabulum, the Kirschner wire was inserted from each guide hole to examine the anatomical relationship between the acetabulum and the pelvic vessels. We calculated the frequency of pelvic vessel punctures and measured the distance from the acetabular surface to the pelvic vessels at each guide hole. RESULTS: Our findings revealed that pelvic vessels do not exist in certain parts of the posterior area of the acetabulum. Furthermore, in this area, intrapelvic vessels are either lacking or located at a distance ≥31 mm from the surface of the acetabulum. CONCLUSION: The posterior area of the acetabulum, excluding its central portion, appeared to be the safety zone for acetabular screw fixation in Japanese cadavers.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pelvis / Bone Screws / Arthroplasty, Replacement, Hip / Asian People / Hip Joint / Acetabulum Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Surg (Hong Kong) Journal subject: ORTOPEDIA Year: 2017 Type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pelvis / Bone Screws / Arthroplasty, Replacement, Hip / Asian People / Hip Joint / Acetabulum Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Surg (Hong Kong) Journal subject: ORTOPEDIA Year: 2017 Type: Article Affiliation country: Japan