Your browser doesn't support javascript.
loading
The quality of platelet concentrates related to corrected count increment: linking in vitro to in vivo.
Saris, Anno; Kreuger, Aukje L; Ten Brinke, Anja; Kerkhoffs, Jean Louis H; Middelburg, Rutger A; Zwaginga, Jaap Jan; van der Meer, Pieter F.
Affiliation
  • Saris A; Department Immunopathology, Sanquin Research, University of Amsterdam, Amsterdam, the Netherlands.
  • Kreuger AL; Landsteiner Laboratory, Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands.
  • Ten Brinke A; Center for Clinical Transfusion Research, Sanquin Research, Leiden University Medical Center, Leiden, the Netherlands.
  • Kerkhoffs JLH; Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands.
  • Middelburg RA; Department Immunopathology, Sanquin Research, University of Amsterdam, Amsterdam, the Netherlands.
  • Zwaginga JJ; Landsteiner Laboratory, Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands.
  • van der Meer PF; Center for Clinical Transfusion Research, Sanquin Research, Leiden University Medical Center, Leiden, the Netherlands.
Transfusion ; 59(2): 697-706, 2019 02.
Article in En | MEDLINE | ID: mdl-30226275
ABSTRACT

BACKGROUND:

Storage of platelet concentrates (PCs) results in reduced recovery and survival of transfused platelets (PLTs). Upon storage PLTs develop storage lesion that can be monitored by several laboratory tests. However, correlation of these descriptive tests with corrected count increments (CCIs), a marker frequently used to establish the effectiveness of PLT transfusions, is limited or unknown. This study investigated to what extent a functional test or a combined in vitro rating score improves the correlation of laboratory tests with 1-hour CCI. STUDY DESIGN AND

METHODS:

PCs were analyzed using six different laboratory tests (n = 123) before transfusion in a prophylactic setting to 74 hematooncologic patients. Linear regression and Spearman correlation were used to determine associations between descriptive (either separately or combined in an in vitro rating score) or functional test results and 1-hour CCIs obtained after transfusion.

RESULTS:

CD62P expression (r = -0.45), annexin V binding (r = -0.36), the updated in vitro rating score (r = 0.50), and PLT responsiveness after thrombin receptor activator for peptide-6 (TRAP) (r = 0.43-0.57) or adenosine diphosphate stimulation (r = 0.11-0.51) significantly correlated to 1-hour CCIs obtained after transfusion, whereas lactate concentration, ThromboLUX score, and thromboelastography measurements did not. The strongest correlations were observed for in vitro rating score and PLT responsiveness after TRAP stimulation and these tests could explain 24 and 33% of the observed variation in 1-hour CCI, respectively.

CONCLUSION:

Combining descriptive markers in one in vitro rating score improved correlation to 1-hour CCI compared to the tests separately. Of all tests investigated, mean PLT responsiveness after TRAP stimulation showed the strongest clinical correlation and was best able to predict the 1-hour CCI.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Quality Control / Blood Platelets / Platelet Transfusion / P-Selectin Type of study: Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Transfusion Year: 2019 Type: Article Affiliation country: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Quality Control / Blood Platelets / Platelet Transfusion / P-Selectin Type of study: Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Transfusion Year: 2019 Type: Article Affiliation country: Netherlands