Your browser doesn't support javascript.
loading
Optimized Diffusion-Weighting Gradient Waveform Design (ODGD) formulation for motion compensation and concomitant gradient nulling.
Peña-Nogales, Óscar; Zhang, Yuxin; Wang, Xiaoke; de Luis-Garcia, Rodrigo; Aja-Fernández, Santiago; Holmes, James H; Hernando, Diego.
Affiliation
  • Peña-Nogales Ó; Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain.
  • Zhang Y; Departments of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin.
  • Wang X; Radiology, University of Wisconsin-Madison, Madison, Wisconsin.
  • de Luis-Garcia R; Radiology, University of Wisconsin-Madison, Madison, Wisconsin.
  • Aja-Fernández S; Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin.
  • Holmes JH; Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain.
  • Hernando D; Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain.
Magn Reson Med ; 81(2): 989-1003, 2019 02.
Article in En | MEDLINE | ID: mdl-30394568
PURPOSE: To present a novel Optimized Diffusion-weighting Gradient waveform Design (ODGD) method for the design of minimum echo time (TE), bulk motion-compensated, and concomitant gradient (CG)-nulling waveforms for diffusion MRI. METHODS: ODGD motion-compensated waveforms were designed for various moment-nullings Mn (n = 0, 1, 2), for a range of b-values, and spatial resolutions, both without (ODGD-Mn ) and with CG-nulling (ODGD-Mn -CG). Phantom and in-vivo (brain and liver) experiments were conducted with various ODGD waveforms to compare motion robustness, signal-to-noise ratio (SNR), and apparent diffusion coefficient (ADC) maps with state-of-the-art waveforms. RESULTS: ODGD-Mn and ODGD-Mn -CG waveforms reduced the TE of state-of-the-art waveforms. This TE reduction resulted in significantly higher SNR (P < 0.05) in both phantom and in-vivo experiments. ODGD-M1 improved the SNR of BIPOLAR (42.8 ± 5.3 vs. 32.9 ± 3.3) in the brain, and ODGD-M2 the SNR of motion-compensated (MOCO) and Convex Optimized Diffusion Encoding-M2 (CODE-M2 ) (12.3 ± 3.6 vs. 9.7 ± 2.9 and 10.2 ± 3.4, respectively) in the liver. Further, ODGD-M2 also showed excellent motion robustness in the liver. ODGD-Mn -CG waveforms reduced the CG-related dephasing effects of non CG-nulling waveforms in phantom and in-vivo experiments, resulting in accurate ADC maps. CONCLUSIONS: ODGD waveforms enable motion-robust diffusion MRI with reduced TEs, increased SNR, and reduced ADC bias compared to state-of-the-art waveforms in theoretical results, simulations, phantoms and in-vivo experiments.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Echo-Planar Imaging / Phantoms, Imaging / Diffusion Magnetic Resonance Imaging / Motion Limits: Humans Language: En Journal: Magn Reson Med Journal subject: DIAGNOSTICO POR IMAGEM Year: 2019 Type: Article Affiliation country: Spain

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Echo-Planar Imaging / Phantoms, Imaging / Diffusion Magnetic Resonance Imaging / Motion Limits: Humans Language: En Journal: Magn Reson Med Journal subject: DIAGNOSTICO POR IMAGEM Year: 2019 Type: Article Affiliation country: Spain