Osteosynthesis of sternal fractures with double locking compression plate fixation: a retrospective cohort study.
Kalberer, Nina; Frima, Herman; Michelitsch, Christian; Kloka, Jan; Sommer, Christoph.
Affiliation
  • Kalberer N; Department of Trauma Surgery, Kantonsspital Graubünden, Loëstrasse 170, 7000, Chur, Switzerland.
  • Frima H; Department of Trauma Surgery, Kantonsspital Graubünden, Loëstrasse 170, 7000, Chur, Switzerland. hfrima@gmail.com.
  • Michelitsch C; Department of Trauma Surgery, Kantonsspital Graubünden, Loëstrasse 170, 7000, Chur, Switzerland.
  • Kloka J; Department of Anaesthesiology, Universitätsklinikum Frankfurt am Main, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
  • Sommer C; Department of Trauma Surgery, Kantonsspital Graubünden, Loëstrasse 170, 7000, Chur, Switzerland.
Eur J Orthop Surg Traumatol ; 30(1): 75-81, 2020 Jan.
Article in En | MEDLINE | ID: mdl-31456035
PURPOSE: Sternal fractures are rare injuries and mostly treated non-operatively. In selected cases, internal fixation becomes necessary. No standard operative approach has been determined yet among experts. The aim of this study is to describe our treatment algorithm and results after operative stabilisation of sternal fractures with locking compression plates (LCP), mainly focusing on the functional outcome. METHODS: A retrospective cohort study was conducted. We included all patients after operative stabilisation of a sternal fracture between 2008 and 2016. Endpoints were the functional outcome using the Activities of Daily Living (ADL) score, pain analysed by the numeric rating scale (NRS), breathing ability, complications and implant removal. RESULTS: Eighteen out of 153 (12%) patients with a sternal fracture underwent operation. Three patients were lost to follow-up. Eleven out of 15 (73%) patients were treated with double straight LCP 3.5 mm implants and 4 (27%) patients with pre-countered LCP 3.5 mm implants. Mean follow-up was 57 months. The median ADL score was 1 (1-4), the median NRS was 0 (0-9), and respiratory complaints scored a median of 1 (1-4). No non-union, hardware failure or implant-related complication occurred. Post-operative complications were pneumonia (20%) and respiratory insufficiency (20%). Implants were removed in 4/15 (27%) patients; three times due to implant-related irritation, once on patient's request. CONCLUSION: Operative stabilisation of sternal fractures with double LCP 3.5 mm provides excellent long-term functional results and seems to be an appropriate option for internal fixation. The rate of post-operative complications is low; however, 27% had a second operation for implant removal.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Postoperative Care / Sternum / Bone Plates / Fractures, Bone / Fracture Fixation, Internal Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: Europa Language: En Journal: Eur J Orthop Surg Traumatol Year: 2020 Type: Article Affiliation country: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Postoperative Care / Sternum / Bone Plates / Fractures, Bone / Fracture Fixation, Internal Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: Europa Language: En Journal: Eur J Orthop Surg Traumatol Year: 2020 Type: Article Affiliation country: Switzerland