Your browser doesn't support javascript.
loading
Three-dimensional mean CT attenuation value of pure and part-solid ground-glass lung nodules may predict invasiveness in early adenocarcinoma.
Kitazawa, S; Saeki, Y; Kobayashi, N; Kikuchi, S; Goto, Y; Sato, Y.
Affiliation
  • Kitazawa S; Department of General Thoracic Surgery, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 Japan.
  • Saeki Y; Department of General Thoracic Surgery, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 Japan.
  • Kobayashi N; Department of General Thoracic Surgery, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 Japan.
  • Kikuchi S; Department of General Thoracic Surgery, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 Japan.
  • Goto Y; Department of General Thoracic Surgery, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 Japan.
  • Sato Y; Department of General Thoracic Surgery, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 Japan. Electronic address: ysato@md.tsukuba.ac.jp.
Clin Radiol ; 74(12): 944-949, 2019 Dec.
Article in En | MEDLINE | ID: mdl-31630766
AIM: This study evaluated the relationship between three-dimensional (3D) mean computed tomography (CT) attenuation values of ground-glass nodules (GGN) and pathological invasiveness in early lung adenocarcinoma. The diagnostic accuracy of 3D CT attenuation values was compared with that of two-dimensional (2D) CT attenuation values and standardised uptake value on positron-emission tomography (PET). MATERIALS AND METHODS: Surgical and radiological data from 96 pure or part-solid GGNs of <20 mm were analysed retrospectively. Mean 2D and 3D CT attenuation values of the tumours were obtained with semi-automated volumetric software. Pathological invasiveness was diagnosed according to the International Association for the Study of Lung Cancer (IASLC))/American Thoracic Society (ATS)/European Respiratory Society (ERS) classification. Pre-invasive lesions and minimally invasive adenocarcinomas were classified as non-invasive adenocarcinoma. Univariate and multivariate analyses determined relationships between pathological invasiveness and clinical/radiological findings. Receiver operating characteristic (ROC) analysis was performed to determine the optimal cut-off value for detecting invasive adenocarcinoma. RESULTS: A total of 66 non-invasive and 30 invasive adenocarcinoma cases between 2010 and 2016 were analysed. Univariate analysis revealed four tumour invasiveness-associated predictors: maximum diameter, SUVmax, mean 2D CT attenuation value, and mean 3D CT attenuation value (p<0.05). Multivariate analysis revealed that the maximum diameter, SUVmax, and mean 3D CT attenuation value were significant predictors of pathological invasiveness (p=0.023, 0.022, 0.004). The area under the ROC curve to predict invasive adenocarcinoma for mean 3D CT attenuation value was 0.838 and the cut-off value was -489 HU. CONCLUSION: The mean 3D CT attenuation value could distinguish pre-invasive lesions and minimally invasive adenocarcinoma from invasive adenocarcinoma.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Adenocarcinoma / Tomography, X-Ray Computed / Solitary Pulmonary Nodule / Lung Neoplasms Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Clin Radiol Year: 2019 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Adenocarcinoma / Tomography, X-Ray Computed / Solitary Pulmonary Nodule / Lung Neoplasms Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Clin Radiol Year: 2019 Type: Article