Evaluation of WASPLab Software To Automatically Read chromID CPS Elite Agar for Reporting of Urine Cultures.
Faron, Matthew L; Buchan, Blake W; Samra, Hasan; Ledeboer, Nathan A.
Affiliation
  • Faron ML; Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • Buchan BW; Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • Samra H; Wisconsin Diagnostic Laboratories, Milwaukee, Wisconsin, USA.
  • Ledeboer NA; Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
J Clin Microbiol ; 58(1)2019 12 23.
Article in En | MEDLINE | ID: mdl-31694967
ABSTRACT
Urine cultures are among the most common specimens received by clinical laboratories and generate a major share of the laboratory workload. Chromogenic agar can expedite culture results, but technologist review is still needed. In this study, we evaluated the ability of the WASPLab software to interpret urine specimens plated onto chromID CPS Elite (CPSE) agar. Urine specimens submitted for bacterial culture were plated onto CPSE agar with a 1-µl loop using the WASP. Each plate was imaged after 0 and 18 h of incubation, and colonies were enumerated by color using the WASPLab software and a technologist's reading from a high-definition (HD) monitor. The results were reported as negative if <10 colonies/plate were detected. Laboratory information system (LIS) time stamps were used to measure the time to result. A total of 1,581 urine cultures were tested. The sensitivity and specificity of the software were 99.8% and 68.5%, respectively, which included 2 manual-positive/automation-negative (MP/AN) results and 170 manual-negative/automation-positive (MN/AP) results. Of the 170 MN/AP specimens, 116 were caused by microcolonies missed by the technologist. The remaining MN/AP results were caused by either count differences near the 10-colony threshold (n = 43) or count differences of >50 CFU (n = 11). The use of both CPSE agar and the WASPLab software improved the time to result for urine culture, reducing the average time to result by 4 h 42 min for negative specimens and 3 h 28 min for positive specimens compared to that with standard-of-care testing. These data demonstrate that the use of CPSE agar and automated plate reading has the potential to improve turnaround time while maintaining high sensitivity and reducing urine culture workload.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Software / Bacteriological Techniques / Urinalysis / Automation, Laboratory Type of study: Diagnostic_studies / Guideline Limits: Humans Language: En Journal: J Clin Microbiol Year: 2019 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Software / Bacteriological Techniques / Urinalysis / Automation, Laboratory Type of study: Diagnostic_studies / Guideline Limits: Humans Language: En Journal: J Clin Microbiol Year: 2019 Type: Article Affiliation country: United States