Analysis of 4 Cases of Electrocution due to Direct Current Electronic Hunter.
Zhu, L L; Tong, F; Liang, Y; Lopsong, T Z; Huang, W S; Liu, Y L; Zhou, Y W.
Affiliation
  • Zhu LL; Department of Forensic Medicine, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China.
  • Tong F; Department of Forensic Medicine, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China.
  • Liang Y; Department of Forensic Medicine, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China.
  • Lopsong TZ; Department of Forensic Medicine, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China.
  • Huang WS; Department of Forensic Medicine, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China.
  • Liu YL; Department of Forensic Medicine, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China.
  • Zhou YW; Department of Forensic Medicine, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China.
Fa Yi Xue Za Zhi ; 35(5): 592-595, 2019 Oct.
Article in En, Zh | MEDLINE | ID: mdl-31833295
ABSTRACT
ABSTRACT Objective To summarize the characteristics of cases of electrocution due to direct current (DC) electronic hunter, and to provide references for forensic identification. Methods Four cases of electrocution due to DC electronic hunter were collected. Statistical analysis was carried out from the perspective of the scene and electric marks distribution, damage characteristics and histopathological changes. Results All the 4 cases of electrocution were accidental events. There were multiple electric marks, most of which were located in the lower limbs with serious damage. Some strip type electric marks were visible. Conclusion The distribution, morphological characteristics and severity of the electric marks caused by DC electronic hunter are different from those of the ordinary low-voltage alternating current damage. It is alerting that there would be actions of destroying the scene and abandoning the corpse in such cases.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electric Injuries / Electricity Type of study: Prognostic_studies Limits: Humans Language: En / Zh Journal: Fa Yi Xue Za Zhi Journal subject: JURISPRUDENCIA Year: 2019 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electric Injuries / Electricity Type of study: Prognostic_studies Limits: Humans Language: En / Zh Journal: Fa Yi Xue Za Zhi Journal subject: JURISPRUDENCIA Year: 2019 Type: Article Affiliation country: China