CAD-CAP: a 25,000-image database serving the development of artificial intelligence for capsule endoscopy.
Leenhardt, Romain; Li, Cynthia; Le Mouel, Jean-Philippe; Rahmi, Gabriel; Saurin, Jean Christophe; Cholet, Franck; Boureille, Arnaud; Amiot, Xavier; Delvaux, Michel; Duburque, Clotilde; Leandri, Chloé; Gérard, Romain; Lecleire, Stéphane; Mesli, Farida; Nion-Larmurier, Isabelle; Romain, Olivier; Sacher-Huvelin, Sylvie; Simon-Shane, Camille; Vanbiervliet, Geoffroy; Marteau, Philippe; Histace, Aymeric; Dray, Xavier.
Affiliation
  • Leenhardt R; Sorbonne University, Endoscopy Unit.
  • Li C; Drexel University, College of Arts & Sciences, Philadelphia, Pennsylvania, United States.
  • Le Mouel JP; Gastroenterology, Amiens University Hospital, Université de Picardie Jules Verne, Amiens, France.
  • Rahmi G; Georges Pompidou European Hospital, APHP, Department of Gastroenterology and Endoscopy, Paris, France.
  • Saurin JC; Department of Endoscopy and Gastroenterology, Pavillon L, Hôpital Edouard Herriot, Lyon, France.
  • Cholet F; Digestive Endoscopy Unit, University Hospital, Brest, France.
  • Boureille A; Department of Hepato-Gastroenterology, Institut des Maladies de l'Appareil Digestif, Nantes, France.
  • Amiot X; Tenon Hospital, Gastroenterology Department, Paris, France.
  • Delvaux M; CHU Strasbourg, Gastroenterology Department, Strasbourg, France.
  • Duburque C; Lomme Hospital, Gastroenterology Department, Lomme, France.
  • Leandri C; Cochin Hospital Gastroenterology Department, Paris, France.
  • Gérard R; CHRU Lille, Gastroenterology Department, Lille, France.
  • Lecleire S; CHU Rouen, Gastroenterology Department, Rouen, France.
  • Mesli F; CHU Henri Mondor, Gastroenterology Department, Creteil, France.
  • Nion-Larmurier I; Sorbonne University, Endoscopy Unit.
  • Romain O; ETIS, Université de Cergy-Pontoise, ENSEA, CNRS, Cergy-Pontoise Cedex, France.
  • Sacher-Huvelin S; Department of Hepato-Gastroenterology, Institut des Maladies de l'Appareil Digestif, Nantes, France.
  • Simon-Shane C; ETIS, Université de Cergy-Pontoise, ENSEA, CNRS, Cergy-Pontoise Cedex, France.
  • Vanbiervliet G; CHU Nice, Gastroenterology and Endoscopy Unit, Nice, France.
  • Marteau P; Sorbonne University, Endoscopy Unit.
  • Histace A; ETIS, Université de Cergy-Pontoise, ENSEA, CNRS, Cergy-Pontoise Cedex, France.
  • Dray X; Sorbonne University, Endoscopy Unit.
Endosc Int Open ; 8(3): E415-E420, 2020 Mar.
Article in En | MEDLINE | ID: mdl-32118115
Background and study aims Capsule endoscopy (CE) is the preferred method for small bowel (SB) exploration. With a mean number of 50,000 SB frames per video, SBCE reading is time-consuming and tedious (30 to 60 minutes per video). We describe a large, multicenter database named CAD-CAP (Computer-Assisted Diagnosis for CAPsule Endoscopy, CAD-CAP). This database aims to serve the development of CAD tools for CE reading. Materials and methods Twelve French endoscopy centers were involved. All available third-generation SB-CE videos (Pillcam, Medtronic) were retrospectively selected from these centers and deidentified. Any pathological frame was extracted and included in the database. Manual segmentation of findings within these frames was performed by two pre-med students trained and supervised by an expert reader. All frames were then classified by type and clinical relevance by a panel of three expert readers. An automated extraction process was also developed to create a dataset of normal, proofread, control images from normal, complete, SB-CE videos. Results Four-thousand-one-hundred-and-seventy-four SB-CE were included. Of them, 1,480 videos (35 %) containing at least one pathological finding were selected. Findings from 5,184 frames (with their short video sequences) were extracted and delimited: 718 frames with fresh blood, 3,097 frames with vascular lesions, and 1,369 frames with inflammatory and ulcerative lesions. Twenty-thousand normal frames were extracted from 206 SB-CE normal videos. CAD-CAP has already been used for development of automated tools for angiectasia detection and also for two international challenges on medical computerized analysis.

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Clinical_trials / Guideline Language: En Journal: Endosc Int Open Year: 2020 Type: Article