Your browser doesn't support javascript.
loading
Development of a Smart Splint to Monitor Different Parameters during the Treatment Process.
De Agustín Del Burgo, José María; Blaya Haro, Fernando; D'Amato, Roberto; Juanes Méndez, Juan Antonio.
Affiliation
  • De Agustín Del Burgo JM; Campus Miguel de Unamuno, Universidad de Salamanca, 37007 Salamanca, Spain.
  • Blaya Haro F; ETSIDI-Departamento de Ingeniería Mecánica, Química y Diseño Industrial, Universidad Politécnica de Madrid (UPM), Ronda de Valencia 3, 28012 Madrid, Spain.
  • D'Amato R; ETSIDI-Departamento de Ingeniería Mecánica, Química y Diseño Industrial, Universidad Politécnica de Madrid (UPM), Ronda de Valencia 3, 28012 Madrid, Spain.
  • Juanes Méndez JA; Campus Miguel de Unamuno, Universidad de Salamanca, 37007 Salamanca, Spain.
Sensors (Basel) ; 20(15)2020 Jul 29.
Article in En | MEDLINE | ID: mdl-32751119
ABSTRACT
For certain musculoskeletal complex rupture injuries, the only treatment available is the use of immobilization splints. This type of treatment usually causes discomfort and certain setbacks in patients. In addition, other complications are usually generated at the vascular, muscular, or articular level. Currently, there is a really possible alternative that would solve these problems and even allows a faster and better recovery. This is possible thanks to the application of engineering on additive manufacturing techniques and the use of biocompatible materials available in the market. This study proposes the use of these materials and techniques, including sensor integration inside the splints. The main parameters considered to be studied are pressure, humidity, and temperature. These aspects are combined and analyzed to determine any kind of unexpected evolution of the treatment. This way, it will be possible to monitor some signals that would be studied to detect problems that are associated to the very initial stage of the treatment. The goal of this study is to generate a smart splint by using biomaterials and engineering techniques based on the advanced manufacturing and sensor system, for clinical purposes. The results show that the prototype of the smart splint allows to get data when it is placed over the arm of a patient. Two temperatures are read during the treatment in contact with the skin and between skin and splint. The humidity variations due to sweat inside the splint are also read by a humidity sensor. A pressure sensor detects slight changes of pressure inside the splint. In addition, an infrared sensor has been included as a presence detector.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Splints / Monitoring, Physiologic / Musculoskeletal System Limits: Humans Language: En Journal: Sensors (Basel) Year: 2020 Type: Article Affiliation country: Spain

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Splints / Monitoring, Physiologic / Musculoskeletal System Limits: Humans Language: En Journal: Sensors (Basel) Year: 2020 Type: Article Affiliation country: Spain