Your browser doesn't support javascript.
loading
Finite element simulations of hyperpolarized gas DWI in micro-CT meshes of acinar airways: validating the cylinder and stretched exponential models of lung microstructural length scales.
Chan, Ho-Fung; Collier, Guilhem J; Parra-Robles, Juan; Wild, Jim M.
Affiliation
  • Chan HF; POLARIS, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.
  • Collier GJ; POLARIS, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.
  • Parra-Robles J; POLARIS, Department of Infection, Immunity & Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.
  • Wild JM; Faculty of Pharmacy, Universidad Complutense de Madrid, Madrid, Spain.
Magn Reson Med ; 86(1): 514-525, 2021 07.
Article in En | MEDLINE | ID: mdl-33624325
PURPOSE: This work assesses the accuracy of the stretched exponential (SEM) and cylinder models of lung microstructural length scales that can be derived from hyperpolarized gas DWI. This was achieved by simulating 3 He and 129 Xe DWI signals within two micro-CT-derived realistic acinar airspace meshes that represent healthy and idiopathic pulmonary fibrosis lungs. METHODS: The healthy and idiopathic pulmonary fibrosis acinar airway meshes were derived from segmentations of 3D micro-CT images of excised human lungs and meshed for finite element simulations of the Bloch-Torrey equations. 3 He and 129 Xe multiple b value DWI experiments across a range of diffusion times (3 He Δ = 1.6 ms; 129 Xe Δ = 5 to 20 ms) were simulated in each mesh. Global SEM mean diffusive length scale and cylinder model mean chord length value was derived from each finite element simulation and compared against each mesh's mean linear intercept length, calculated from intercept length measurements within micro-CT segmentation masks. RESULTS: The SEM-derived mean diffusive length scale was within ±10% of the mean linear intercept length for simulations with both 3 He (Δ = 1.6 ms) and 129 Xe (Δ = 7 to 13 ms) in the healthy mesh, and with 129 Xe (Δ = 13 to 20 ms) for the idiopathic pulmonary fibrosis mesh, whereas for the cylinder model-derived mean chord length the closest agreement with mean linear intercept length (11.7% and 22.6% difference) was at 129 Xe Δ = 20 ms for both healthy and IPF meshes, respectively. CONCLUSION: This work validates the use of the SEM for accurate estimation of acinar dimensions and indicates that the SEM is relatively robust across a range of experimental conditions and acinar length scales.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Xenon Isotopes / Idiopathic Pulmonary Fibrosis Limits: Humans / Male Language: En Journal: Magn Reson Med Journal subject: DIAGNOSTICO POR IMAGEM Year: 2021 Type: Article Affiliation country: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Xenon Isotopes / Idiopathic Pulmonary Fibrosis Limits: Humans / Male Language: En Journal: Magn Reson Med Journal subject: DIAGNOSTICO POR IMAGEM Year: 2021 Type: Article Affiliation country: United kingdom