Your browser doesn't support javascript.
loading
Development of chemiluminescence method based on serum type I collagen hydroxyl terminal peptide ß special sequence (ß-CTX).
Huo, Zhen; Liu, Xueke; Wu, Yongfeng; Liang, Yong; Xu, Ruyue; Ma, Yongfang; Song, Li; Shen, Jing; Tang, Xiaolong.
Affiliation
  • Huo Z; Medcial School, Anhui University of Science & Technology, Huainan, China.
  • Liu X; Institute of Environment-Friendly Materials and Occupational Health, Anhui University of Science and Technology, Wuhu, China.
  • Wu Y; Department of Clinical Laboratory Medicine, The Fourth Affiliated Hospital, Zhejiang University School of Medicine, Yiwu, China.
  • Liang Y; Department of Clinical Laboratory Medicine, Yijishan Hospital, Wannan Medical College, Wuhu, China.
  • Xu R; Huai'an Hospital, Xuzhou Medical College and Huai'an Second Hospital, Huai'an, China.
  • Ma Y; Medcial School, Anhui University of Science & Technology, Huainan, China.
  • Song L; Institute of Environment-Friendly Materials and Occupational Health, Anhui University of Science and Technology, Wuhu, China.
  • Shen J; Medcial School, Anhui University of Science & Technology, Huainan, China.
  • Tang X; Institute of Environment-Friendly Materials and Occupational Health, Anhui University of Science and Technology, Wuhu, China.
Scand J Clin Lab Invest ; 81(6): 494-501, 2021 Oct.
Article in En | MEDLINE | ID: mdl-34325600
ABSTRACT
The objective of this work is to develop and verify the analytical performance of a chemiluminescence immunoassay for the specific sequence ß-carboxy-terminal cross-linking telopeptide of type I collagen (ß-CTX) in human serum. Two specific monoclonal antibodies (mAb-8A03 and mAb-3D12) with high affinity for ß-CTX were selected, and, under optimized conditions, a chemiluminescence immunoassay method (CLIA) for ß-CTX was established. The CLIA of ß-CTX detected ß-CTX in a wide range of 2.0-6000 ng/L. The recovery rate in serum is 95-105%, the specificity is high, and the cross-reaction rate with common easily interfering substances is low (not more than 0.01%). The CLIA correlates well with Roche electrochemiluminescence immunoassay (ECLIA), with a correlation coefficient of 0.9551, which fully meets the requirements of clinical analysis. The developed ß-CTX CLIA kit has high sensitivity and good stability. It has the same performance as the commercial Roche ECLIA kit and can be applied clinically.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Peptides / Collagen Type I / Luminescent Measurements Type of study: Diagnostic_studies / Screening_studies Limits: Humans Language: En Journal: Scand J Clin Lab Invest Year: 2021 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Peptides / Collagen Type I / Luminescent Measurements Type of study: Diagnostic_studies / Screening_studies Limits: Humans Language: En Journal: Scand J Clin Lab Invest Year: 2021 Type: Article Affiliation country: China