Your browser doesn't support javascript.
loading
Metabolic profiles of human brain parenchyma and glioma for rapid tissue diagnosis by targeted desorption electrospray ionization mass spectrometry.
Chen, Rong; Brown, Hannah Marie; Cooks, R Graham.
Affiliation
  • Chen R; Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907-2084, USA.
  • Brown HM; Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907-2084, USA.
  • Cooks RG; Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907-2084, USA. cooks@purdue.edu.
Anal Bioanal Chem ; 413(25): 6213-6224, 2021 Oct.
Article in En | MEDLINE | ID: mdl-34373931
ABSTRACT
Desorption electrospray ionization mass spectrometry (DESI-MS) is well suited for intraoperative tissue analysis since it requires little sample preparation and offers rapid and sensitive molecular diagnostics. Currently, intraoperative assessment of the tumor cell percentage of glioma biopsies can be made by measuring a single metabolite, N-acetylaspartate (NAA). The inclusion of additional biomarkers will likely improve the accuracy when distinguishing brain parenchyma from glioma by DESI-MS. To explore this possibility, mass spectra were recorded for extracts from 32 unmodified human brain samples with known pathology. Statistical analysis of data obtained from full-scan and multiple reaction monitoring (MRM) profiles identified discriminatory metabolites, namely gamma-aminobutyric acid (GABA), creatine, glutamic acid, carnitine, and hexane-1,2,3,4,5,6-hexol (abbreviated as hexol), as well as the established biomarker NAA. Brain parenchyma was readily differentiated from glioma based on these metabolites as measured both in full-scan mass spectra and by the intensities of their characteristic MRM transitions. New DESI-MS methods (5 min acquisition using full scans and MS/MS), developed to measure ion abundance ratios among these metabolites, were tested using smears of 29 brain samples. Ion abundance ratios based on signals for GABA, creatine, carnitine, and hexol all had sensitivities > 90%, specificities > 80%, and accuracies > 85%. Prospectively, the implementation of diagnostic ion abundance ratios should strengthen the discriminatory power of individual biomarkers and enhance method robustness against signal fluctuations, resulting in an improved DESI-MS method of glioma diagnosis.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Brain Neoplasms / Spectrometry, Mass, Electrospray Ionization / Parenchymal Tissue / Glioma Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Anal Bioanal Chem Year: 2021 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Brain Neoplasms / Spectrometry, Mass, Electrospray Ionization / Parenchymal Tissue / Glioma Type of study: Diagnostic_studies / Prognostic_studies Limits: Humans Language: En Journal: Anal Bioanal Chem Year: 2021 Type: Article Affiliation country: United States