Your browser doesn't support javascript.
loading
Prevention of Venous Thromboembolism in Microvascular Surgery Patients Using Weight-Based Unfractionated Heparin Infusions.
Bertolaccini, Corinne M; Prazak, Ann Marie B; Goodwin, Isak A; Kwok, Alvin; Mendenhall, Shaun D; Rockwell, W Bradford; Agarwal, Jayant; Pannucci, Christopher J.
Affiliation
  • Bertolaccini CM; Department of Pharmacy Services, University of Utah Health, Salt Lake City, Utah.
  • Prazak AMB; Department of Pharmacy Services, University of Utah Health, Salt Lake City, Utah.
  • Goodwin IA; Division of Plastic Surgery, University of Utah Health, Salt Lake City, Utah.
  • Kwok A; Division of Plastic Surgery, University of Utah Health, Salt Lake City, Utah.
  • Mendenhall SD; Division of Plastic Surgery, University of Utah Health, Salt Lake City, Utah.
  • Rockwell WB; Division of Plastic Surgery, University of Utah Health, Salt Lake City, Utah.
  • Agarwal J; Division of Plastic Surgery, University of Utah Health, Salt Lake City, Utah.
  • Pannucci CJ; Plastic Surgery Northwest, Spokane, Washington.
J Reconstr Microsurg ; 38(5): 395-401, 2022 Jun.
Article in En | MEDLINE | ID: mdl-34428806
BACKGROUND: Unfractionated heparin infusions are commonly used in microvascular surgery to prevent microvascular thrombosis. Previously, fixed-dose heparin infusions were believed to provide sufficient venous thromboembolism (VTE) prophylaxis; however, we now know that this practice is inadequate for the majority of patients. Anti-factor Xa (aFXa) level is a measure of unfractionated heparin efficacy and safety. This study evaluated the pharmacodynamics of weight-based dose heparin infusions and the impacts of real-time aFXa-guided heparin dose adjustments. METHODS: This prospective clinical trial enrolled adult microvascular surgery patients who received a weight-based heparin dose following a microsurgical procedure. Steady-state aFXa levels were monitored, and patients with out-of-range levels received dose adjustments. The study outcomes assessed were aFXa levels at a dose of heparin 10 units/kg/hour, time to adequate aFXa level, number of dose adjustments required to reach in-range aFXa levels, and clinically relevant bleeding and VTE at 90 days. RESULTS: Twenty-one patients were prospectively recruited, and usable data were available for twenty patients. Four of twenty patients (20%) had adequate prophylaxis at a heparin dose of 10 units/kg/hour. Among patients who received dose adjustments and achieved in-range aFXa levels, the median number of dose adjustments was 2 and the median weight-based dose was 11 units/kg/hour. The percentage of patients with in-range levels was significantly increased (65 vs. 15%, p = 0.0002) as a result of real-time dose adjustments. The rate of VTE at 90 days was 0%, and clinically relevant bleeding rate at 90 days was 15%. CONCLUSION: Weight-based heparin infusions at a rate of 10 units/kg/hour provide a detectable level of anticoagulation for some patients following microsurgical procedures, but most patients require dose adjustment to ensure adequate VTE prophylaxis.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Venous Thromboembolism Type of study: Clinical_trials / Observational_studies Limits: Adult / Humans Language: En Journal: J Reconstr Microsurg Journal subject: NEUROCIRURGIA Year: 2022 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Venous Thromboembolism Type of study: Clinical_trials / Observational_studies Limits: Adult / Humans Language: En Journal: J Reconstr Microsurg Journal subject: NEUROCIRURGIA Year: 2022 Type: Article