Your browser doesn't support javascript.
loading
An active fixation quadripolar left ventricular lead for cardiac resynchronization therapy with reduced postoperative complication rates.
Robertson, Calum; Duffey, Owen; Tang, Pok-Tin; Fairhurst, Natalie; Monteiro, Cristiana; Green, Peregrine; Grogono, Joanna; Davies, Mark; Lewis, Andrew; Wijesurendra, Rohan; Ormerod, Julian; Gamble, James; Ginks, Matthew; Rajappan, Kim; Bashir, Yaver; Betts, Tim R; Herring, Neil.
Affiliation
  • Robertson C; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Duffey O; Department of Physiology Anatomy and Genetics, Burdon Sanderson Cardiac Science Centre, University of Oxford, Oxford, UK.
  • Tang PT; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Fairhurst N; Department of Physiology Anatomy and Genetics, Burdon Sanderson Cardiac Science Centre, University of Oxford, Oxford, UK.
  • Monteiro C; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Green P; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Grogono J; Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK.
  • Davies M; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Lewis A; Department of Physiology Anatomy and Genetics, Burdon Sanderson Cardiac Science Centre, University of Oxford, Oxford, UK.
  • Wijesurendra R; Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK.
  • Ormerod J; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Gamble J; Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK.
  • Ginks M; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Rajappan K; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Bashir Y; Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK.
  • Betts TR; Department of Cardiology, Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Herring N; Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK.
J Cardiovasc Electrophysiol ; 33(3): 458-463, 2022 03.
Article in En | MEDLINE | ID: mdl-34968010
BACKGROUND: The rate of left ventricular (LV) lead displacement after cardiac resynchronization therapy (CRT) remains high despite improvements in lead technology. In 2017, a novel quadripolar lead with active fixation technology became available in the UK. METHODS: This was a retrospective, observational study analyzing device complications in 476 consecutive patients undergoing successful first-time implantation of a CRT device at a tertiary center from 2017 to 2020. RESULTS: Both active (n = 135) and passive fixation (n = 341) quadripolar leads had similar success rates for implantation (99.3% vs. 98.8%, p = 1.00), although the pacing threshold (0.89 [0.60-1.25] vs. 1.00 [0.70-1.60] V, p = .01) and lead impedance (632 [552-794] vs. 730 [636-862] Ohms, p < .0001) were significantly lower for the active fixation lead. Patients receiving an active fixation lead had a reduced incidence of lead displacement at 6 months (0.74% vs. 4.69%, p = .036). There was no significant difference in the rate of right atrial (RA) and right ventricular (RV) lead displacement between the two groups (RA: 1.48% vs. 1.17%, p = .68; RV: 2.22% vs. 1.76%, p = .72). Reprogramming the LV lead after displacement was unsuccessful in most cases (successful reprogramming: Active fix = 0/1, Passive fix = 1/16) therefore nearly all patients required a repeat procedure. As a result, the rate of intervention within 6 months for lead displacement was significantly lower when patients were implanted with the active fixation lead (0.74% vs. 4.40%, p = .049). CONCLUSION: The novel active fixation lead in our study has a lower incidence of lead displacement and re-intervention compared to conventional quadripolar leads for CRT.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cardiac Resynchronization Therapy / Heart Failure Type of study: Diagnostic_studies / Observational_studies Limits: Humans Language: En Journal: J Cardiovasc Electrophysiol Journal subject: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Year: 2022 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cardiac Resynchronization Therapy / Heart Failure Type of study: Diagnostic_studies / Observational_studies Limits: Humans Language: En Journal: J Cardiovasc Electrophysiol Journal subject: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Year: 2022 Type: Article