Your browser doesn't support javascript.
loading
Semi-automated 18F-FDG PET segmentation methods for tumor volume determination in Non-Hodgkin lymphoma patients: a literature review, implementation and multi-threshold evaluation.
Keijzer, Kylie; Niezink, Anne G H; de Boer, Janneke W; van Doesum, Jaap A; Noordzij, Walter; van Meerten, Tom; van Dijk, Lisanne V.
Affiliation
  • Keijzer K; Department of Hematology, University Medical Center Groningen, Hanzeplein 1, 9713GZ Groningen, the Netherlands.
  • Niezink AGH; Department of Radiation Oncology, University Medical Center Groningen, Hanzeplein 1, 9713GZ Groningen, the Netherlands.
  • de Boer JW; Department of Radiation Oncology, University Medical Center Groningen, Hanzeplein 1, 9713GZ Groningen, the Netherlands.
  • van Doesum JA; Department of Hematology, University Medical Center Groningen, Hanzeplein 1, 9713GZ Groningen, the Netherlands.
  • Noordzij W; Department of Hematology, University Medical Center Groningen, Hanzeplein 1, 9713GZ Groningen, the Netherlands.
  • van Meerten T; Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Hanzeplein 1, 9713GZ Groningen, the Netherlands.
  • van Dijk LV; Department of Hematology, University Medical Center Groningen, Hanzeplein 1, 9713GZ Groningen, the Netherlands.
Comput Struct Biotechnol J ; 21: 1102-1114, 2023.
Article in En | MEDLINE | ID: mdl-36789266
ABSTRACT
In the treatment of Non-Hodgkin lymphoma (NHL), multiple therapeutic options are available. Improving outcome predictions are essential to optimize treatment. The metabolic active tumor volume (MATV) has shown to be a prognostic factor in NHL. It is usually retrieved using semi-automated thresholding methods based on standardized uptake values (SUV), calculated from 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET) images. However, there is currently no consensus method for NHL. The aim of this study was to review literature on different segmentation methods used, and to evaluate selected methods by using an in house created software tool. A software tool, MUltiple SUV Threshold (MUST)-segmenter was developed where tumor locations are identified by placing seed-points on the PET images, followed by subsequent region growing. Based on a literature review, 9 SUV thresholding methods were selected and MATVs were extracted. The MUST-segmenter was utilized in a cohort of 68 patients with NHL. Differences in MATVs were assessed with paired t-tests, and correlations and distributions figures. High variability and significant differences between the MATVs based on different segmentation methods (p < 0.05) were observed in the NHL patients. Median MATVs ranged from 35 to 211 cc. No consensus for determining MATV is available based on the literature. Using the MUST-segmenter with 9 selected SUV thresholding methods, we demonstrated a large and significant variation in MATVs. Identifying the most optimal segmentation method for patients with NHL is essential to further improve predictions of toxicity, response, and treatment outcomes, which can be facilitated by the MUST-segmenter.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Comput Struct Biotechnol J Year: 2023 Type: Article Affiliation country: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Comput Struct Biotechnol J Year: 2023 Type: Article Affiliation country: Netherlands