Your browser doesn't support javascript.
loading
Intensity modulated proton arc therapy via geometry-based energy selection for ependymoma.
Cao, Wenhua; Li, Yupeng; Zhang, Xiaodong; Poenisch, Falk; Yepes, Pablo; Sahoo, Narayan; Grosshans, David; McGovern, Susan; Gunn, G Brandon; Frank, Steven J; Zhu, Xiaorong R.
Affiliation
  • Cao W; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Li Y; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Zhang X; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Poenisch F; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Yepes P; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Sahoo N; Department of Physics and Astronomy, Rice University, Houston, Texas, USA.
  • Grosshans D; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • McGovern S; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Gunn GB; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Frank SJ; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Zhu XR; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
J Appl Clin Med Phys ; 24(7): e13954, 2023 Jul.
Article in En | MEDLINE | ID: mdl-36913484
ABSTRACT

PURPOSE:

We developed and tested a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources similar to those for regular intensity-modulated proton therapy (IMPT) plans and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries.

METHODS:

Our IMPAT planning method consists of a geometry-based energy selection step with major scanning spot contributions as inputs computed using ray-tracing and single-Gaussian approximation of lateral spot profiles. Based on the geometric relation of scanning spots and dose voxels, our energy selection module selects a minimum set of energy layers at each gantry angle such that each target voxel is covered by sufficient scanning spots as specified by the planner, with dose contributions above the specified threshold. Finally, IMPAT plans are generated by robustly optimizing scanning spots of the selected energy layers using a commercial proton treatment planning system (TPS). The IMPAT plan quality was assessed for four ependymoma patients. Reference three-field IMPT plans were created with similar planning objective functions and compared with the IMPAT plans.

RESULTS:

In all plans, the prescribed dose covered 95% of the clinical target volume (CTV) while maintaining similar maximum doses for the brainstem. While IMPAT and IMPT achieved comparable plan robustness, the IMPAT plans achieved better homogeneity and conformity than the IMPT plans. The IMPAT plans also exhibited higher relative biological effectiveness (RBE) enhancement than did the corresponding reference IMPT plans for the CTV in all four patients and brainstem in three of them.

CONCLUSIONS:

The proposed method demonstrated potential as an efficient technique for IMPAT planning and may offer a dosimetric benefit for patients with ependymoma or tumors in close proximity to critical organs. IMPAT plans created using this method had elevated RBE enhancement associated with increased linear energy transfer (LET) in both targets and abutting critical organs.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Ependymoma / Radiotherapy, Intensity-Modulated / Proton Therapy Type of study: Etiology_studies Limits: Humans Language: En Journal: J Appl Clin Med Phys Journal subject: BIOFISICA Year: 2023 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Ependymoma / Radiotherapy, Intensity-Modulated / Proton Therapy Type of study: Etiology_studies Limits: Humans Language: En Journal: J Appl Clin Med Phys Journal subject: BIOFISICA Year: 2023 Type: Article Affiliation country: United States