Your browser doesn't support javascript.
loading
Nitrogen-, Sulfur-, and Fluorine-Codoped Carbon Dots with Low Excitation Potential and High Electrochemiluminescence Efficiency for Sensitive Detection of Matrix Metalloproteinase-2.
Guo, Yu-Zhuo; Yang, Yu-Ting; Chen, Yi-Fei; Liu, Jia-Li; Chai, Ya-Qin; Yuan, Ruo.
Affiliation
  • Guo YZ; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Yang YT; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Chen YF; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Liu JL; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Chai YQ; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Yuan R; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
Anal Chem ; 95(17): 7021-7029, 2023 05 02.
Article in En | MEDLINE | ID: mdl-37081730
ABSTRACT
In this study, nitrogen-, sulfur-, and fluorine-codoped carbon dots (NSF-CDs) with high electrochemiluminescence (ECL) efficiency were developed as novel emitters to fabricate an ECL biosensor for sensitive detection of matrix metalloproteinase 2 (MMP-2). Impressively, compared to previously reported CDs, NSF-CDs with narrow band gap not only decreased the excitation voltage to reduce the side reaction and the damage on biomolecules but also had hydrogen bonds to vastly enhance the ECL efficiency. Furthermore, an improved exonuclease III (Exo III)-assisted nucleic acid amplification method was established to convert trace MMP-2 into a mass of output DNA, which greatly improved the target conversion efficiency and ECL signal. Hence, the ECL biosensor has realized the sensitive detection of MMP-2 proteins from 10 fg/mL to 10 ng/mL with a limit of detection of 6.83 fg/mL and has been successfully applied in the detection of MMP-2 from Hela and MCF-7 cancer cells. This strategy offered neoteric CDs as ECL emitters for sensitive testing of biomarkers in medical research.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Quantum Dots Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Anal Chem Year: 2023 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Quantum Dots Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Anal Chem Year: 2023 Type: Article