Your browser doesn't support javascript.
loading
Confirmation of Statin and Fibrate Use from Small-Volume Archived Plasma Samples by High-Throughput LC-MS/MS Method.
Kusovschi, Jennifer D; Ivanova, Anna A; Gardner, Michael S; McGarrah, Robert W; Kraus, William E; Kuklenyik, Zsuzsanna; Pirkle, James L; Barr, John R.
Affiliation
  • Kusovschi JD; Clinical Chemistry Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Ivanova AA; Clinical Chemistry Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Gardner MS; Clinical Chemistry Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • McGarrah RW; Duke Molecular Physiology Institute, Duke University School of Medicine, Duke University, Durham, NC 27701, USA.
  • Kraus WE; Duke Molecular Physiology Institute, Duke University School of Medicine, Duke University, Durham, NC 27701, USA.
  • Kuklenyik Z; Clinical Chemistry Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Pirkle JL; Clinical Chemistry Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Barr JR; Clinical Chemistry Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
Int J Mol Sci ; 24(9)2023 Apr 27.
Article in En | MEDLINE | ID: mdl-37175638
Designing studies for lipid-metabolism-related biomarker discovery is challenging because of the high prevalence of various statin and fibrate usage for lipid-lowering therapies. When the statin and fibrate use is determined based on self-reports, patient adherence to the prescribed statin dose regimen remains unknown. A potentially more accurate way to verify a patient's medication adherence is by direct analytical measurements. Current analytical methods are prohibitive because of the limited panel of drugs per test and large sample volume requirement that is not available from archived samples. A 4-min-long method was developed for the detection of seven statins and three fibrates using 10 µL of plasma analyzed via reverse-phase liquid chromatography and tandem mass spectrometry. The method was applied to the analysis of 941 archived plasma samples collected from patients before cardiac catheterization. When statin use was self-reported, statins were detected in 78.6% of the samples. In the case of self-reported atorvastatin use, the agreement with detection was 90.2%. However, when no statin use was reported, 42.4% of the samples had detectable levels of statins, with a similar range of concentrations as the samples from the self-reported statin users. The method is highly applicable in population studies designed for biomarker discovery or diet and lifestyle intervention studies, where the accuracy of statin or fibrate use may strongly affect the statistical evaluation of the biomarker data.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hydroxymethylglutaryl-CoA Reductase Inhibitors Type of study: Risk_factors_studies Limits: Humans Language: En Journal: Int J Mol Sci Year: 2023 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hydroxymethylglutaryl-CoA Reductase Inhibitors Type of study: Risk_factors_studies Limits: Humans Language: En Journal: Int J Mol Sci Year: 2023 Type: Article Affiliation country: United States