Your browser doesn't support javascript.
loading
Side-by-side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial.
Paik, Woo Hyun; Jung, Min Kyu; Kim, Dong Uk; Song, Tae Jun; Yang, Min Jae; Choi, Young Hoon; Kim, Joo Seong; Lee, Min Woo; Choi, Jin Ho; Lee, Sang Hyub.
Affiliation
  • Paik WH; Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
  • Jung MK; Department of Internal Medicine, School of Medicine, Kyungpook National University, Daegu, Korea.
  • Kim DU; Department of Internal Medicine, College of Medicine, Pusan National University, Yangsan, Korea.
  • Song TJ; Biomedical Research Institute, Pusan National University Hospital, Busan, Korea.
  • Yang MJ; Department of Gastroenterology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.
  • Choi YH; Department of Gastroenterology, Ajou University School of Medicine, Suwon, Korea.
  • Kim JS; Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Lee MW; Department of Internal Medicine, Dongguk University Medical Center, Dongguk University College of Medicine, Goyang, Korea.
  • Choi JH; Department of Internal Medicine, Armed Forces Capital Hospital, Seongnam, Korea.
  • Lee SH; Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Dig Endosc ; 36(4): 473-480, 2024 Apr.
Article in En | MEDLINE | ID: mdl-37612129
ABSTRACT

OBJECTIVES:

We aimed to evaluate the efficacy and safety of metal stents compared with plastic stents when bilateral side-by-side stents were deployed for malignant hilar biliary obstruction (MHBO).

METHODS:

Fifty patients with unresectable advanced MHBO were randomly assigned to the metal stent (MS, n = 25) or plastic stent group (PS, n = 25). Fully covered self-expandable metal stents with 6 mm diameter and plastic stents with either 7F straight or double pigtail were used for MS and PS groups, respectively. Time to recurrent biliary obstruction (TRBO) was evaluated as the primary outcome.

RESULTS:

Both groups had 100% technical success rates; 88% and 76% of clinical success rates were obtained in MS and PS, respectively. Although stent migrations were more frequent in MS than PS (48% vs. 16%, P = 0.02), the mean TRBO was significantly longer in MS (190 days; 95% confidence interval [CI] 121-260 days vs. 96 days; 95% CI 50-141 days, P = 0.02). The placement of plastic stents (hazard ratio 2.42; 95% CI 1.24-4.73; P = 0.01) was the only significant risk factor associated with TRBO in multivariable analysis. The rates of adverse events were similar between the two groups (difference 0%; 95% CI -25% to 25%; P > 0.99).

CONCLUSIONS:

During bilateral side-by-side deployment in MHBO, the use of metal stents appears to be preferable to plastic stents in terms of TRBO, despite a higher frequency of stent migration.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bile Duct Neoplasms / Cholestasis / Self Expandable Metallic Stents Type of study: Clinical_trials / Risk_factors_studies Limits: Humans Language: En Journal: Dig Endosc Journal subject: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Year: 2024 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bile Duct Neoplasms / Cholestasis / Self Expandable Metallic Stents Type of study: Clinical_trials / Risk_factors_studies Limits: Humans Language: En Journal: Dig Endosc Journal subject: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Year: 2024 Type: Article