Your browser doesn't support javascript.
loading
Performance Assessment of Anti-Xa Assay-Based Heparin Dosing Protocol in Pediatric Patients on Extracorporeal Membrane Oxygenation.
Al-Jazairi, Abdulrazaq S; Shorog, Eman M; Owaidah, Tarek M; Al Dalaty, Hani; Alheriash, Yasser A; Almehizia, Rayd A; Alahmadi, Mamdouh D.
Affiliation
  • Al-Jazairi AS; Clinical Trials Transformation Initiative, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
  • Shorog EM; Pharmaceutical Care Division, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
  • Owaidah TM; Clinical Pharmacy Department, King Khalid University, College of Pharmacy, Abha, Saudi Arabia.
  • Al Dalaty H; Department of Pathology and Laboratory Medicine, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
  • Alheriash YA; Cardiovascular Nursing, Department of Nursing Affairs, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
  • Almehizia RA; Pediatric Cardiac Intensive Care Unit, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
  • Alahmadi MD; Pharmaceutical Care Division, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
World J Pediatr Congenit Heart Surg ; 14(6): 723-728, 2023 Nov.
Article in En | MEDLINE | ID: mdl-37654250
ABSTRACT

BACKGROUND:

The use of extracorporeal membrane oxygenation (ECMO) in the postoperative cardiac critical care setting is evolving. Anticoagulation monitoring is among the most challenging aspects of pediatrics. However, there is no consensus on the optimal dosing and monitoring of unfractionated heparin in this setting. To address this, we developed an anti-Xa assay-based protocol derived from the best available clinical and anecdotal evidence of ECMO use and assessed its effectiveness in achieving the anti-Xa assay therapeutic target.

METHODS:

This prospective single-arm study was conducted in the pediatric carcardiac-surgery intensive care unit of a large tertiary hospital. We used two different anti-Xa assay intensity levels based on the patients' bleeding status.

RESULTS:

The median patient age was 7 (interquartile range [IQR] 5-11.25) months, and the median weight was 5.7 (IQR 3.8-13.82) kg. The median ECMO duration was 6 (IQR 4.5-7.5) days. The bleeding protocol was used for most patients. Seventy percent achieved the anti-Xa assay therapeutic target during the study period (median 75.5 h, IQR 60.5-117.5 h). Hemorrhagic complications were reported in 40% of the patients, and thrombotic complications were reported in 25%. The median length of stay was 37 (IQR 22-43) days, with a survival-to-discharge rate of 75%.

CONCLUSIONS:

Despite a failure to achieve the anti-Xa assay target within the first ECMO days, most patients achieved the target by the median ECMO duration. Moreover, using two different anti-Xa assay levels reduced thrombotic complications.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Thrombosis / Extracorporeal Membrane Oxygenation Type of study: Guideline Limits: Child / Humans / Infant Language: En Journal: World J Pediatr Congenit Heart Surg Year: 2023 Type: Article Affiliation country: Saudi Arabia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Thrombosis / Extracorporeal Membrane Oxygenation Type of study: Guideline Limits: Child / Humans / Infant Language: En Journal: World J Pediatr Congenit Heart Surg Year: 2023 Type: Article Affiliation country: Saudi Arabia