Your browser doesn't support javascript.
loading
General purpose models for intravenous anesthetics, the next generation for target-controlled infusion and total intravenous anesthesia?
Vellinga, Remco; Eleveld, Douglas J; Struys, Michel M R F; van den Berg, Johannes P.
Affiliation
  • Vellinga R; Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Eleveld DJ; Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Struys MMRF; Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • van den Berg JP; Department of Basic and Applied Medical Sciences, Ghent University, Ghent, Belgium.
Curr Opin Anaesthesiol ; 36(5): 602-607, 2023 Oct 01.
Article in En | MEDLINE | ID: mdl-37678184
PURPOSE OF REVIEW: There are various pharmacokinetic-dynamic models available, which describe the time course of drug concentration and effect and which can be incorporated into target-controlled infusion (TCI) systems. For anesthesia and sedation, most of these models are derived from narrow patient populations, which restricts applicability for the overall population, including (small) children, elderly, and obese patients. This forces clinicians to select specific models for specific populations. RECENT FINDINGS: Recently, general purpose models have been developed for propofol and remifentanil using data from multiple studies and broad, diverse patient groups. General-purpose models might reduce the risks associated with extrapolation, incorrect usage, and unfamiliarity with a specific TCI-model, as they offer less restrictive boundaries (i.e., the patient "doesn't fit in the selected model") compared with the earlier, simpler models. Extrapolation of a model can lead to delayed recovery or inadequate anesthesia. If multiple models for the same drug are implemented in the pump, it is possible to select the wrong model for that specific case; this can be overcome with one general purpose model implemented in the pump. SUMMARY: This article examines the usability of these general-purpose models in relation to the more traditional models.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Propofol / Anesthetics, Intravenous Type of study: Prognostic_studies Limits: Aged / Child / Humans Language: En Journal: Curr Opin Anaesthesiol Journal subject: ANESTESIOLOGIA Year: 2023 Type: Article Affiliation country: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Propofol / Anesthetics, Intravenous Type of study: Prognostic_studies Limits: Aged / Child / Humans Language: En Journal: Curr Opin Anaesthesiol Journal subject: ANESTESIOLOGIA Year: 2023 Type: Article Affiliation country: Netherlands