Your browser doesn't support javascript.
loading
Location-aware ingestible microdevices for wireless monitoring of gastrointestinal dynamics.
Sharma, Saransh; Ramadi, Khalil B; Poole, Nikhil H; Srinivasan, Shriya S; Ishida, Keiko; Kuosmanen, Johannes; Jenkins, Josh; Aghlmand, Fatemeh; Swift, Margaret B; Shapiro, Mikhail G; Traverso, Giovanni; Emami, Azita.
Affiliation
  • Sharma S; Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA.
  • Ramadi KB; These authors contributed equally: Saransh Sharma, Khalil B. Ramadi.
  • Poole NH; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
  • Srinivasan SS; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
  • Ishida K; Division of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.
  • Kuosmanen J; Tandon School of Engineering, New York University, New York, NY, USA.
  • Jenkins J; These authors contributed equally: Saransh Sharma, Khalil B. Ramadi.
  • Aghlmand F; Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA.
  • Swift MB; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
  • Shapiro MG; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
  • Traverso G; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
  • Emami A; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
Nat Electron ; 6(3): 242-256, 2023 Mar.
Article in En | MEDLINE | ID: mdl-37745833
ABSTRACT
Localization and tracking of ingestible microdevices in the gastrointestinal (GI) tract is valuable for the diagnosis and treatment of GI disorders. Such systems require a large field-of-view of tracking, high spatiotemporal resolution, wirelessly operated microdevices and a non-obstructive field generator that is safe to use in practical settings. However, the capabilities of current systems remain limited. Here, we report three dimensional (3D) localization and tracking of wireless ingestible microdevices in the GI tract of large animals in real time and with millimetre-scale resolution. This is achieved by generating 3D magnetic field gradients in the GI field-of-view using high-efficiency planar electromagnetic coils that encode each spatial point with a distinct magnetic field magnitude. The field magnitude is measured and transmitted by the miniaturized, low-power and wireless microdevices to decode their location as they travel through the GI tract. This system could be useful for quantitative assessment of the GI transit-time, precision targeting of therapeutic interventions and minimally invasive procedures.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Nat Electron Year: 2023 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Nat Electron Year: 2023 Type: Article Affiliation country: United States