Prediction of radiation pneumonitis using the effective α/ß of lungs and heart in NSCLC patients treated with proton beam therapy.
Radiother Oncol
; 190: 110013, 2024 Jan.
Article
in En
| MEDLINE
| ID: mdl-37972734
PURPOSE: Radiation pneumonitis (RP) remains a major complication in non-small cell lung cancer (NSCLC) patients undergoing radiochemotherapy (RCHT). Traditionally, the mean lung dose (MLD) and the volume of the total lung receiving at least 20 Gy (V20Gy) are used to predict RP in patients treated with normo-fractionated photon therapy. However, other models, including the actual dose-distribution in the lungs using the effective α/ß model or a combination of radiation doses to the lungs and heart, have been proposed for predicting RP. Moreover, the models established for photons may not hold for patients treated with passively-scattered proton therapy (PSPT). Therefore, we here tested and validated novel predictive parameters for RP in NSCLC patient treated with PSPT. METHODS: Data on the occurrence of RP, structure files and dose-volume histogram parameters for lungs and heart of 96 NSCLC patients, treated with PSPT and concurrent chemotherapy, was retrospectively retrieved from prospective clinical studies of two international centers. Data was randomly split into a training set (64 patients) and a validation set (32 patients). Statistical analyses were performed using binomial logistic regression. RESULTS: The biologically effective dose (BED) of the'lungs - GTV' significantly predicted RP ≥ grade 2 in the training-set using both a univariate model (p = 0.019, AUCtrain = 0.72) and a multivariate model in combination with the effective α/ß parameter of the heart (pBED = 0.006, [Formula: see text] = 0.043, AUCtrain = 0.74). However, these results did not hold in the validation-set (AUCval = 0.52 andAUCval = 0.50, respectively). Moreover, these models were found to neither outperform a model built with the MLD (p = 0.015, AUCtrain = 0.73, AUCval = 0.51), nor a multivariate model additionally including the V20Gy of the heart (pMLD = 0.039, pV20Gy,heart = 0.58, AUCtrain = 0.74, AUCval = 0.53). CONCLUSION: Using the effective α/ß parameter of the lungs and heart we achieved similar performance to commonly used models built for photon therapy, such as MLD, in predicting RP ≥ grade 2. Therefore, prediction models developed for photon RCHT still hold for patients treated with PSPT.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Radiation Pneumonitis
/
Carcinoma, Non-Small-Cell Lung
/
Proton Therapy
/
Lung Neoplasms
Limits:
Humans
Language:
En
Journal:
Radiother Oncol
Year:
2024
Type:
Article