The degree of permanent pacemaker dependence and clinical outcomes following transcatheter aortic valve implantation: implications for procedural technique.
Dykun, Iryna; Mahabadi, Amir Abbas; Jehn, Stefanie; Kalra, Ankur; Isogai, Toshiaki; Wazni, Oussama M; Kanj, Mohamad; Krishnaswamy, Amar; Reed, Grant W; Yun, James J; Totzeck, Matthias; Jánosi, R Alexander; Lind, Alexander Y; Kapadia, Samir R; Rassaf, Tienush; Puri, Rishi.
Affiliation
  • Dykun I; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Mahabadi AA; Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany.
  • Jehn S; Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany.
  • Kalra A; Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany.
  • Isogai T; Krannert Cardiovascular Research Center, Division of Cardiovascular Medicine, Indiana University School of Medicine, Indianapolis, IN, USA.
  • Wazni OM; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Kanj M; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Krishnaswamy A; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Reed GW; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Yun JJ; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Totzeck M; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Jánosi RA; Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany.
  • Lind AY; Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany.
  • Kapadia SR; Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany.
  • Rassaf T; Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, J2-3, Cleveland, OH 44195, USA.
  • Puri R; Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Essen, Germany.
Eur Heart J Open ; 3(6): oead127, 2023 Nov.
Article in En | MEDLINE | ID: mdl-38105920
ABSTRACT

Aims:

Conduction abnormalities necessitating permanent pacemaker (PPM) implantation remain the most frequent complication post-transcatheter aortic valve implantation (TAVI), yet reliance on PPM function varies. We evaluated the association of right-ventricular (RV)-stimulation rate post-TAVI with 1-year major adverse cardiovascular events (MACE) (all-cause mortality and heart failure hospitalization). Methods and

results:

This retrospective cohort study of patients undergoing TAVI in two high-volume centers included patients with existing PPM pre-TAVI or new PPM post-TAVI. There was a bimodal distribution of RV-stimulation rates stratifying patients into two groups of either low [≤10% 1.0 (0.0, 3.6)] or high [>10% 96.0 (54.0, 99.9)] RV-stimulation rate post-TAVI. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated comparing MACE in patients with high vs. low RV-stimulation rates post-TAVI. Of 4659 patients, 408 patients (8.6%) had an existing PPM pre-TAVI and 361 patients (7.7%) underwent PPM implantation post-TAVI. Mean age was 82.3 ± 8.1 years, 39% were women. A high RV-stimulation rate (>10%) development post-TAVI is associated with a two-fold increased risk for MACE [1.97 (1.20, 3.25), P = 0.008]. Valve implantation depth was an independent predictor of high RV-stimulation rate [odds ratio (95% CI) 1.58 (1.21, 2.06), P=<0.001] and itself associated with MACE [1.27 (1.00, 1.59), P = 0.047].

Conclusion:

Greater RV-stimulation rates post-TAVI correlate with increased 1-year MACE in patients with new PPM post-TAVI or in those with existing PPM but low RV-stimulation rates pre-TAVI. A shallower valve implantation depth reduces the risk of greater RV-stimulation rates post-TAVI, correlating with improved patient outcomes. These data highlight the importance of a meticulous implant technique even in TAVI recipients with pre-existing PPMs.