Your browser doesn't support javascript.
loading
Loop-mediated isothermal amplification linked a nanoparticles-based biosensor for detecting Epstein-Barr virus.
Yang, Xinggui; Zeng, Xiaoyan; Huang, Junfei; Yang, Ludi; Mao, Sha; Chen, Xu; Wang, Yu; Wei, Xiaoyu; Li, Shijun.
Affiliation
  • Yang X; Guizhou Provincial Center for Disease Control and Prevention, Guiyang, 550004, Guizhou, People's Republic of China.
  • Zeng X; The Second Affiliated Hospital, Guizhou University of Traditional Chinese Medicine, Guiyang, 550003, Guizhou, People's Republic of China.
  • Huang J; Guizhou Provincial Center for Disease Control and Prevention, Guiyang, 550004, Guizhou, People's Republic of China.
  • Yang L; Tongren People's Hospital, Tongren, 554399, Guizhou, People's Republic of China.
  • Mao S; Guizhou Provincial Center for Disease Control and Prevention, Guiyang, 550004, Guizhou, People's Republic of China.
  • Chen X; The Second Affiliated Hospital, Guizhou University of Traditional Chinese Medicine, Guiyang, 550003, Guizhou, People's Republic of China.
  • Wang Y; Department of Clinical Laboratory, The First People's Hospital of Guiyang, Guiyang, 550002, Guizhou, People's Republic of China.
  • Wei X; Guizhou Provincial Center for Disease Control and Prevention, Guiyang, 550004, Guizhou, People's Republic of China.
  • Li S; Guizhou Provincial Center for Disease Control and Prevention, Guiyang, 550004, Guizhou, People's Republic of China. zjumedjun@163.com.
Appl Microbiol Biotechnol ; 108(1): 91, 2024 Dec.
Article in En | MEDLINE | ID: mdl-38212962
ABSTRACT
Epstein-Barr virus (EBV) is a ubiquitous gamma herpesvirus that maintains a lifelong latent association with B lymphocytes. Here, a rapid and reliable diagnosis platform for detecting EBV infection, employing loop-mediated isothermal amplification (LAMP) combined with a gold nanoparticles-based lateral flow biosensors (AuNPs-LFB) (termed LAMP Amplification Mediated AuNPs-LFB Detection, LAMAD), was developed in the current study. A set of specific LAMP primers targeting the Epstein-Barr nuclear antigen (EBNA) leader protein (EBNA-LP) gene was designed and synthesized. Subsequently, these templates extracted from various pathogens and whole blood samples were used to optimize and evaluate the EBV-LAMAD assay. As a result, the limit of detection (LoD) of the EBV-LAMAD assay was 45 copies/reaction. The EBV-LAMAD assay can detect all representative EBV pathogens used in the study, and of note, no cross-reactions were observed with other non-EBV organisms. Moreover, the whole workflow of the EBV-LAMAD assay can be completed within 70 min, including rapid EBV template preparation, EBV-LAMP amplification, and AuNPs-LFB-mediated detection. Taken together, the EBV-LAMAD assay targeting the EBNA-LP gene is a rapid, simplified, sensitive, reliable, and easy-to-use detection protocol that can be used as a competitive potential diagnostic/screening tool for EBV infection in clinical settings, especially in basic laboratories in resource-limited regions. KEY POINTS • A novel, simplified, and easy-to-use AuNPs-LFB biosensor was designed and prepared. • LAMP combined with an AuNPs-LFB targeting the novel EBNA-LP gene was established. • EBV-LAMAD is a rapid, sensitive, and reliable detection protocol for EBV infection.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Epstein-Barr Virus Infections / Molecular Diagnostic Techniques / Metal Nanoparticles Type of study: Diagnostic_studies / Guideline Limits: Humans Language: En Journal: Appl Microbiol Biotechnol Year: 2024 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Epstein-Barr Virus Infections / Molecular Diagnostic Techniques / Metal Nanoparticles Type of study: Diagnostic_studies / Guideline Limits: Humans Language: En Journal: Appl Microbiol Biotechnol Year: 2024 Type: Article