Your browser doesn't support javascript.
loading
Diagnostic and Prognostic Potential of Multiparametric Renal MRI in Kidney Transplant Patients.
Echeverria-Chasco, Rebeca; Martin-Moreno, Paloma L; Aramendía-Vidaurreta, Veronica; Garcia-Ruiz, Leyre; Mora-Gutiérrez, José María; Vidorreta, Marta; Villanueva, Arantxa; Cano, David; Bastarrika, Gorka; Garcia-Fernandez, Nuria; Fernández-Seara, Maria A.
Affiliation
  • Echeverria-Chasco R; Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
  • Martin-Moreno PL; Instituto de Investigación Sanitaria de Navarra (IdiSNA), Pamplona, Navarra, Spain.
  • Aramendía-Vidaurreta V; Instituto de Investigación Sanitaria de Navarra (IdiSNA), Pamplona, Navarra, Spain.
  • Garcia-Ruiz L; Department of Nephrology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
  • Mora-Gutiérrez JM; Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
  • Vidorreta M; Instituto de Investigación Sanitaria de Navarra (IdiSNA), Pamplona, Navarra, Spain.
  • Villanueva A; Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
  • Cano D; Instituto de Investigación Sanitaria de Navarra (IdiSNA), Pamplona, Navarra, Spain.
  • Bastarrika G; Instituto de Investigación Sanitaria de Navarra (IdiSNA), Pamplona, Navarra, Spain.
  • Garcia-Fernandez N; Department of Nephrology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
  • Fernández-Seara MA; Siemens Healthcare, Madrid, Spain.
J Magn Reson Imaging ; 2024 Jan 19.
Article in En | MEDLINE | ID: mdl-38240395
ABSTRACT

BACKGROUND:

Multiparametric MRI provides assessment of functional and structural parameters in kidney allografts. It offers a non-invasive alternative to the current reference standard of kidney biopsy.

PURPOSE:

To evaluate the diagnostic and prognostic utility of MRI parameters in the assessment of allograft function in the first 3-months post-transplantation. STUDY TYPE Prospective.

SUBJECTS:

32 transplant recipients (54 ± 17 years, 20 females), divided into two groups according to estimated glomerular filtration rate (eGFR) at 3-months post-transplantation inferior graft function (IGF; eGFR<45 mL/min/1.73 m2 , n = 10) and superior graft function (SGF; eGFR ≥ 45 mL/min/1.73 m2 , n = 22). Further categorization was based on the need for hemodialysis (C1) and decrease in s-creatinine (C2) at 1-week post-transplantation delayed-graft-function (DGF n = 4 C1, n = 10 C2) and early graft-function (EGF n = 28 C1, n = 22 C2). FIELD STRENGTH/SEQUENCE 3-T, pseudo-continuous arterial spin labeling, T1-mapping, and diffusion-weighted imaging. ASSESSMENT Multiparametric MRI was evaluated at 1-week in all patients and 3-months after transplantation in 28 patients. Renal blood flow (RBF), diffusion coefficients (ADC, ΔADC, D, ∆ $$ \Delta $$ D, D*, flowing fraction f), T1 and ∆ $$ \Delta $$ T1 were calculated in cortex and medulla. The diagnostic and prognostic value of these parameters, obtained at 3-months and 1-week post-transplantation, respectively, was evaluated in the cortex to discriminate between DGF and EGF, and between SGF and IGF. STATISTICAL TESTS Logistic regression, receiver-operating-characteristics, area-under-the-curve (AUC), confidence intervals (CIs), analysis-of-variance, t-test, Wilcoxon-Mann-Whitney test, Fisher's exact test, Pearson's correlation. P-value<0.05 was considered significant.

RESULTS:

DGF patients exhibited significantly lower cortical RBF and f and higher D*. The diagnostic value of MRI for detecting DGF was excellent (AUC = 100%). Significant differences between patients with IGF and SGF were found in RBF, ∆T1 , and ∆D. Multiparametric MRI showed higher diagnostic (AUC = 95.32%; CI 88%-100%) and prognostic (AUC = 97.47%, CI 92%-100%) values for detecting IGF than eGFR (AUC = 89.50%, CI 79%-100%). DATA

CONCLUSION:

Multiparametric MRI may show high diagnostic and prognostic value in transplanted patients, yielding better results compared to eGFR measurements. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY Stage 1.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: J Magn Reson Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2024 Type: Article Affiliation country: Spain

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: J Magn Reson Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2024 Type: Article Affiliation country: Spain