Your browser doesn't support javascript.
loading
Evaluation of the availability of single-position treatment with a rotating gantry and the validity of deformable image registration dose assessment for pancreatic cancer carbon-ion radiotherapy.
Miyasaka, Yuya; Kawashiro, Shohei; Lee, Sung Hyun; Souda, Hikaru; Ichikawa, Mayumi; Chai, Hongbo; Ishizawa, Miyu; Ono, Takuya; Sato, Hiraku; Iwai, Takeo.
Affiliation
  • Miyasaka Y; Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
  • Kawashiro S; Department of Radiation Oncology, Kanagawa Cancer Center, Yokohama, Japan.
  • Lee SH; Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
  • Souda H; Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
  • Ichikawa M; Department of Radiology, Yamagata University Faculty of Medicine, Yamagata, Japan.
  • Chai H; Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
  • Ishizawa M; Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
  • Ono T; Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
  • Sato H; Department of Radiology, Yamagata University Faculty of Medicine, Yamagata, Japan.
  • Iwai T; Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
J Appl Clin Med Phys ; 25(6): e14330, 2024 Jun.
Article in En | MEDLINE | ID: mdl-38478368
ABSTRACT

BACKGROUND:

This study aimed to evaluate the clinical acceptability of rotational gantry-based single-position carbon-ion radiotherapy (CIRT) to reduce the gastrointestinal (GI) dose in pancreatic cancer. We also evaluated the usefulness of the deformable image registration (DIR)-based dosimetry method for CIRT. MATERIAL AND

METHODS:

Fifteen patients with pancreatic cancer were analyzed. The treatment plans were developed for four beam angles in the supine (SP plan) and prone (PR plan) positions. In the case of using multiple positions, the treatment plan was created with two angles for each of the supine and prone position (SP + PR plan). Dose evaluation for multiple positions was performed in two ways by directly adding the values of the DVH parameters for each position treatment plan (DVH sum), and by calculating the DVH parameters from the accumulative dose distribution created using DIR (DIR sum). The D2cc and D6cc of the stomach and duodenum were recorded for each treatment plan and dosimetry method and compared.

RESULTS:

There were no significant differences among any of the treatment planning and dosimetry methods (p > 0.05). The DVH parameters for the stomach and duodenum were higher in the PR plan and SP plan, respectively, and DVH sum tended to be between the SP and PR plans. DVH sum and DIR sum, DVH sum tended to be higher for D2cc and DIR sum tended to be higher for D6cc.

CONCLUSION:

There were no significant differences in the GI dose, which suggests that treatment with a simple workflow performed in one position should be clinically acceptable. In CIRT, DIR-based dosimetry should be carefully considered because of the potential for increased uncertainty due to the steep dose distributions.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pancreatic Neoplasms / Radiotherapy Dosage / Radiotherapy Planning, Computer-Assisted / Radiotherapy, Intensity-Modulated / Organs at Risk / Heavy Ion Radiotherapy Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: J Appl Clin Med Phys Journal subject: BIOFISICA Year: 2024 Type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pancreatic Neoplasms / Radiotherapy Dosage / Radiotherapy Planning, Computer-Assisted / Radiotherapy, Intensity-Modulated / Organs at Risk / Heavy Ion Radiotherapy Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: J Appl Clin Med Phys Journal subject: BIOFISICA Year: 2024 Type: Article Affiliation country: Japan