Your browser doesn't support javascript.
loading
Corneal biomechanics and their association with severity of lens dislocation in Marfan syndrome.
Jin, Guangming; Zou, Minjie; Li, Longhui; Liu, Zhenzhen; Young, Charlotte; Qi, Haotian; Zheng, Danying.
Affiliation
  • Jin G; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China.
  • Zou M; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China.
  • Li L; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China.
  • Liu Z; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China.
  • Young C; Albany Medical College, 49 New Scotland Ave, Albany, NY, USA.
  • Qi H; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China.
  • Zheng D; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China. zhengdyy@163.com.
Int Ophthalmol ; 44(1): 148, 2024 Mar 19.
Article in En | MEDLINE | ID: mdl-38502381
ABSTRACT

PURPOSE:

To investigate corneal biomechanical properties and its associations with the severity of lens dislocation in patients with Marfan syndrome.

METHODS:

A total of 30 patients with Marfan syndrome and 30 age-, sex- and axial length (AL)-matched controls were recruited. Corneal biomechanical parameters of both groups were measured by CorVis ST and were compared between groups. Potential associations between corneal biomechanical parameters and severity of lens dislocation were also investigated.

RESULTS:

Lower applanation 1 velocity (A1V) (0.13 ± 0.004 vs. 0.15 ± 0.003, P = 0.016), shorter applanation 2 time (A2T)(22.64 ± 0.11 vs. 22.94 ± 0.11, P = 0.013), longer peak distance (PD) (5.03 ± 0.07 vs. 4.81 ± 0.05, P = 0.008), longer radius (R) of highest concavity (7.44 ± 0.16 vs. 6.93 ± 0.14, P = 0.012), greater Ambrosio relational thickness horizontal (ARTh) (603 ± 20 vs. 498 ± 12, P < 0.001), and integrated radius (IR) (8.32 ± 0.25 vs. 8.95 ± 0.21, P = 0.033) were detected among Marfan eyes compared with controls (all P < 0.05). Marfan individuals with more severe lens dislocation tended to have increased stiffness parameter as longer A1T, slower A1V, shorter A2T, slower application 2 velocity (A2V), smaller PD and smaller Distance Amplitude (DA) (P < 0.05).

CONCLUSION:

Marfan patients were detected to have increased corneal stiffness compared with normal subjects. Corneal biomechanical parameters were significantly associated with the severity of lens dislocation in Marfan patients.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Lens Subluxation / Marfan Syndrome Limits: Humans Language: En Journal: Int Ophthalmol Year: 2024 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Lens Subluxation / Marfan Syndrome Limits: Humans Language: En Journal: Int Ophthalmol Year: 2024 Type: Article Affiliation country: China